Thoracic Imaging |
1 From the Department of Radiology and Center for Imaging Science (Y.J.J., K.S.L., S.S.S., S.Y.J., M.J.C.), Division of Pulmonary and Critical Care Medicine, Department of Medicine (H.K., O.J.K.), and Biostatistics Unit (S.K.), Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-Dong, Kangnam-Ku, Seoul 135-710, Korea. Received September 8, 2004; revision requested November 12; revision received November 19; accepted December 30. Address correspondence to K.S.L. (e-mail: kyungs.lee{at}samsung.com).
PURPOSE: To prospectively assess the accuracy of combined wash-in and washout characteristics at dynamic contrast materialenhanced multidetector row computed tomography (CT) in distinguishing benign from malignant solitary pulmonary nodules.
MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. The study included 107 patients (62 men, 45 women; mean age, 55 years; range, 2281 years) with a solitary pulmonary nodule. After unenhanced CT (2.5-mm collimation) scans were obtained, dynamic CT was performed by using a helical technique (series of images obtained throughout the nodule, with 2.5-mm collimation, at 30, 60, 90, and 120 seconds and 4, 5, 9, 12, and 15 minutes) after intravenous injection of contrast medium (120 mL). Tissue diagnosis was made in 70 nodules, and follow-up images showed benignancy in the remaining 37 (no change in size, n = 32; decrease in size, n = 5). CT findings were analyzed in terms of wash-in and washout of contrast medium. Sensitivity, specificity, and accuracy for malignant nodules were calculated by considering both the wash-in and washout characteristics at dynamic CT.
RESULTS: There were 49 malignant and 58 benign nodules. When diagnostic criteria for malignancy of both wash-in of 25 HU or greater and washout of 531 HU were applied, sensitivity, specificity, and accuracy for malignancy were 94% (46 of 49 nodules), 90% (52 of 58 nodules), and 92% (98 of 107 nodules), respectively. Of 58 benign nodules, 27 showed less than 25 HU wash-in, 14 showed persistent contrast enhancement without washout and with wash-in of 25 HU or greater, and 11 showed washout greater than 31 HU and wash-in of 25 HU or greater.
CONCLUSION: Evaluation of solitary pulmonary nodules by analyzing combined wash-in and washout characteristics at dynamic contrast-enhanced multidetector row CT showed 92% accuracy for distinguishing benign nodules from malignant nodules.
© RSNA, 2005
This article has been cited by other articles:
![]() |
F. Girvin and J. P. Ko Pulmonary Nodules: Detection, Assessment, and CAD Am. J. Roentgenol., October 1, 2008; 191(4): 1057 - 1069. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. J. Chae, J.-W. Song, J. B. Seo, B. Krauss, Y. M. Jang, and K.-S. Song Clinical Utility of Dual-Energy CT in the Evaluation of Solitary Pulmonary Nodules: Initial Experience Radiology, September 16, 2008; (2008) 2492071956. [Abstract] [Full Text] |
||||
![]() |
S. Satoh, Y. Kitazume, S. Ohdama, Y. Kimula, S. Taura, and Y. Endo Can Malignant and Benign Pulmonary Nodules Be Differentiated with Diffusion-Weighted MRI? Am. J. Roentgenol., August 1, 2008; 191(2): 464 - 470. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. J. Chae, J. B. Seo, H. W. Goo, N. Kim, K.-S. Song, S. D. Lee, S.-J. Hong, and B. Krauss Xenon Ventilation CT with a Dual-Energy Technique of Dual-Source CT: Initial Experience Radiology, August 1, 2008; 248(2): 615 - 624. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Cronin, B. A. Dwamena, A. M. Kelly, and R. C. Carlos Solitary Pulmonary Nodules: Meta-analytic Comparison of Cross-sectional Imaging Modalities for Diagnosis of Malignancy Radiology, March 1, 2008; 246(3): 772 - 782. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Honda, T. Johkoh, H. Sumikawa, A. Inoue, N. Tomiyama, N. Mihara, Y. Fujita, M. Tsubamoto, M. Yanagawa, T. Daimon, et al. Pulmonary Nodules: 3D Volumetric Measurement with Multidetector CT Effect of Intravenous Contrast Medium Radiology, December 1, 2007; 245(3): 881 - 887. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. S. Lee, C. A. Yi, S. Y. Jeong, Y. J. Jeong, S. Kim, M. J. Chung, H. Y. Kim, Y. K. Kim, and K. H. Lee Solid or Partly Solid Solitary Pulmonary Nodules: Their Characterization Using Contrast Wash-In and Morphologic Features at Helical CT Chest, May 1, 2007; 131(5): 1516 - 1525. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. J. Jeong, C. A. Yi, and K. S. Lee Solitary Pulmonary Nodules: Detection, Characterization, and Guidance for Further Diagnostic Workup and Treatment Am. J. Roentgenol., January 1, 2007; 188(1): 57 - 68. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. B. Lobrano Partnerships in Oncology and Radiology: The Role of Radiology in the Detection, Staging, and Follow-up of Lung Cancer Oncologist, July 1, 2006; 11(7): 774 - 779. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. A Yi, K. S. Lee, B.-T. Kim, J. Y. Choi, O. J. Kwon, H. Kim, Y. M. Shim, and M. J. Chung Tissue Characterization of Solitary Pulmonary Nodule: Comparative Study Between Helical Dynamic CT and Integrated PET/CT J. Nucl. Med., March 1, 2006; 47(3): 443 - 450. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |