Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2373041450
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schmid, M. R.
Right arrow Articles by Weishaupt, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schmid, M. R.
Right arrow Articles by Weishaupt, D.
(Radiology 2005;237:1008-1013.)
© RSNA, 2005


Musculoskeletal Imaging

Interosseous Ligament Tears of the Wrist: Comparison of Multi–Detector Row CT Arthrography and MR Imaging1

Marius R. Schmid, MD, Thomas Schertler, MD, Christian W. Pfirrmann, MD, Nadja Saupe, MD, Mirjana Manestar, MD, Simon Wildermuth, MD and Dominik Weishaupt, MD

1 From the Department of Radiology, Balgrist University Hospital, Forchstrasse 340, CH-8008 Zurich, Switzerland (M.R.S., C.W.P.); and Departments of Diagnostic Radiology (T.S., N.S., S.W., D.W.) and Anatomy (M.M.), University of Zurich, Zurich, Switzerland. Received August 20, 2004; revision requested October 29; revision received December 24; accepted January 21, 2005. Address correspondence to M.R.S. (e-mail: marius.schmid{at}balgrist.ch)

PURPOSE: To compare the accuracy of multi–detector row computed tomographic (CT) arthrography and magnetic resonance (MR) imaging in depicting tears of dorsal, central, and palmar segments of scapholunate (SL) and lunotriquetral (LT) ligaments in cadavers.

MATERIALS AND METHODS: Cadaver wrists were obtained and used according to institutional guidelines and with informed consent of donors prior to death. Nine cadaver wrists of eight subjects were evaluated. MR images were obtained with a 1.5-T MR unit. Imaging protocol included intermediate-weighted coronal and transverse fast spin-echo and coronal three-dimensional gradient-echo sequences. Multi–detector row CT arthrography was performed after tricompartmental injection of 3–6 mL of contrast material with a concentration of 160 mg per milliliter of iodine. Palmar, dorsal, and central segments of both ligaments were analyzed on transverse and coronal MR images and multiplanar multi–detector row CT reconstructions by two musculoskeletal radiologists working independently. Open inspection of the wrists was the reference standard. Sensitivity, specificity, accuracy, and positive and negative predictive values were calculated from the imaging and gross pathologic readings. Statistical significance was calculated with the McNemar test. Weighted {kappa} values for interobserver agreement were calculated for both imaging modalities.

RESULTS: All ligament segments could be visualized in all cases with both imaging modalities. CT arthrography was more sensitive (100%) than MR imaging (60%) in detection of palmar segment tears (P = .62); specificity of both imaging modalities was 77%. Sensitivity (CT arthrography, 86%; MR imaging, 79%) and specificity (CT arthrography, 50%; MR imaging, 25%) for detection of the central segment tears were determined. Dorsal segment tears were detected only with CT arthrography, while all tears were missed with MR imaging (P = .02). Interobserver agreement was better for multi–detector row CT arthrography ({kappa} = 0.37–0.78) than for MR imaging ({kappa} = –0.33 to –0.10).

CONCLUSION: Performance in depiction of palmar and central segment tears of SL and LT ligaments is almost equal for multi–detector row CT arthrography and MR imaging, with much higher interobserver reliability for CT arthrography. CT arthrography is significantly superior to MR imaging in the detection of dorsal segment tears of SL and LT ligaments.

© RSNA, 2005




This article has been cited by other articles:


Home page
RadioGraphicsHome page
T. Moser, J.-C. Dosch, A. Moussaoui, X. Buy, A. Gangi, and J.-L. Dietemann
Multidetector CT Arthrography of the Wrist Joint: How to Do It
RadioGraphics, May 1, 2008; 28(3): 787 - 800.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2005 by the Radiological Society of North America.