Musculoskeletal Imaging |
1 From the Department of Radiology, Balgrist University Hospital, Forchstrasse 340, CH-8008 Zurich, Switzerland (M.R.S., C.W.P.); and Departments of Diagnostic Radiology (T.S., N.S., S.W., D.W.) and Anatomy (M.M.), University of Zurich, Zurich, Switzerland. Received August 20, 2004; revision requested October 29; revision received December 24; accepted January 21, 2005. Address correspondence to M.R.S. (e-mail: marius.schmid{at}balgrist.ch)
PURPOSE: To compare the accuracy of multidetector row computed tomographic (CT) arthrography and magnetic resonance (MR) imaging in depicting tears of dorsal, central, and palmar segments of scapholunate (SL) and lunotriquetral (LT) ligaments in cadavers.
MATERIALS AND METHODS: Cadaver wrists were obtained and used according to institutional guidelines and with informed consent of donors prior to death. Nine cadaver wrists of eight subjects were evaluated. MR images were obtained with a 1.5-T MR unit. Imaging protocol included intermediate-weighted coronal and transverse fast spin-echo and coronal three-dimensional gradient-echo sequences. Multidetector row CT arthrography was performed after tricompartmental injection of 36 mL of contrast material with a concentration of 160 mg per milliliter of iodine. Palmar, dorsal, and central segments of both ligaments were analyzed on transverse and coronal MR images and multiplanar multidetector row CT reconstructions by two musculoskeletal radiologists working independently. Open inspection of the wrists was the reference standard. Sensitivity, specificity, accuracy, and positive and negative predictive values were calculated from the imaging and gross pathologic readings. Statistical significance was calculated with the McNemar test. Weighted
values for interobserver agreement were calculated for both imaging modalities.
RESULTS: All ligament segments could be visualized in all cases with both imaging modalities. CT arthrography was more sensitive (100%) than MR imaging (60%) in detection of palmar segment tears (P = .62); specificity of both imaging modalities was 77%. Sensitivity (CT arthrography, 86%; MR imaging, 79%) and specificity (CT arthrography, 50%; MR imaging, 25%) for detection of the central segment tears were determined. Dorsal segment tears were detected only with CT arthrography, while all tears were missed with MR imaging (P = .02). Interobserver agreement was better for multidetector row CT arthrography (
= 0.370.78) than for MR imaging (
= 0.33 to 0.10).
CONCLUSION: Performance in depiction of palmar and central segment tears of SL and LT ligaments is almost equal for multidetector row CT arthrography and MR imaging, with much higher interobserver reliability for CT arthrography. CT arthrography is significantly superior to MR imaging in the detection of dorsal segment tears of SL and LT ligaments.
© RSNA, 2005
This article has been cited by other articles:
![]() |
T. Moser, J.-C. Dosch, A. Moussaoui, X. Buy, A. Gangi, and J.-L. Dietemann Multidetector CT Arthrography of the Wrist Joint: How to Do It RadioGraphics, May 1, 2008; 28(3): 787 - 800. [Abstract] [Full Text] [PDF] |
||||