Gastrointestinal Imaging |
1 From the Departments of Radiological Sciences (R.I., C.C., F.M., D.M., R.P.), Surgery "Pietro Valdoni," Endoscopic Unit (A.L., E.F., A.S.), and Experimental Medicine and Pathology-Medical Biostatistics (I.N.), University of Rome-La Sapienza, Rome, Italy; and Department of Radiology, Osaka University Graduate School of Medicine, Osaka, Japan (T.M., M.H.). Received October 11, 2004; revision requested December 21; revision received March 3, 2005; accepted March 16. Address correspondence to R.I., Via Arturo Graf 40, 00137 Rome, Italy (e-mail: r_iannaccone{at}yahoo.it).
PURPOSE: To prospectively evaluate the diagnostic accuracy of low-radiation-dose computed tomographic (CT) colonography for detection of colorectal polyps by using two sequential colonoscopies, with the second colonoscopy as the reference standard.
MATERIALS AND METHODS: The study was local ethics committee approved, and all patients gave written informed consent. Colonographic images were acquired by using a low-dose multidetector row CT protocol (effective milliampere-second setting, 10 mAs). Three observers interpreted the CT colonographic data separately and independently by using a two-dimensional technique. Initial conventional colonoscopy was performed by an endoscopist unaware of the CT colonographic findings. Second colonoscopy performed within 2 weeks by a colonoscopist aware of both the CT colonographic and the initial colonoscopic findings served as the reference standard. The sensitivities of CT colonography and initial colonoscopy were calculated on a per-polyp and a per-patient basis. Specificities and positive and negative predictive values also were calculated on a per-patient basis.
RESULTS: Eighty-eight patients underwent CT colonography and initial conventional colonoscopy on the same day. Per-polyp sensitivities were 62% and 83% for CT colonography and initial colonoscopy, respectively. Sensitivities for detection of polyps 6 mm in diameter or larger were 86% and 84% for CT colonography and initial colonoscopy, respectively. Initial colonoscopy failed to depict 16 polyps, six of which were correctly detected with CT colonography. For identification of patients with polyps 6 mm in diameter or larger, CT colonography and initial colonoscopy, respectively, had sensitivities of 84% and 90%, specificities of 82% and 100%, positive predictive values of 70% and 100%, and negative predictive values of 91% and 95%.
CONCLUSION: Low-dose CT colonography compares favorably with colonoscopy for detection of colorectal polyps 6 mm in diameter or larger, with markedly decreased performance for detection of polyps 5 mm in diameter or smaller.
© RSNA, 2005
This article has been cited by other articles:
![]() |
E. Resmini, A. Tagliafico, L. Bacigalupo, G. Giordano, E. Melani, A. Rebora, F. Minuto, G. A. Rollandi, and D. Ferone Computed Tomography Colonography in Acromegaly J. Clin. Endocrinol. Metab., January 1, 2009; 94(1): 218 - 222. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Sosna, T. Sella, O. Sy, P. T. Lavin, R. Eliahou, S. Fraifeld, and E. Libson Critical Analysis of the Performance of Double-Contrast Barium Enema for Detecting Colorectal Polyps >= 6 mm in the Era of CT Colonography Am. J. Roentgenol., February 1, 2008; 190(2): 374 - 385. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Kim, J. M. Lee, H. W. Eun, M. W. Lee, J. K. Han, J. Y. Lee, and B. I. Choi Two- versus Three-dimensional Colon Evaluation with Recently Developed Virtual Dissection Software for CT Colonography Radiology, September 1, 2007; 244(3): 852 - 864. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. S. WERDERMAN CT Colonography Radiol. Technol., March 1, 2007; 78(4): 309CT - 324CT. [Abstract] [Full Text] [PDF] |
||||