Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print November 22, 2005, 10.1148/radiol.2381041532
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2381041532v1
238/1/280    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fenchel, M.
Right arrow Articles by Miller, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fenchel, M.
Right arrow Articles by Miller, S.
(Radiology 2005;238:280-291.)
© RSNA, 2005


Technical Developments

Atherosclerotic Disease: Whole-Body Cardiovascular Imaging with MR System with 32 Receiver Channels and Total-Body Surface Coil Technology—Initial Clinical Results1

Michael Fenchel, MD, Albertus M. Scheule, MD, Norbert I. Stauder, MD, Ulrich Kramer, MD, Katrin Tomaschko, RT, Thomas Nägele, MD, Christiane Bretschneider, Heinz-Peter Schlemmer, MD, Claus D. Claussen, MD and Stephan Miller, MD

1 From the Departments of Diagnostic Radiology (M.F., N.I.S., U.K., K.T., C.B., H.P.S., C.D.C., S.M.), Cardiovascular Surgery (A.M.S.), and Neuroradiology (T.N.), Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076 Tuebingen, Germany. Received September 10, 2004; revision requested November 18; revision received January 20, 2005; final version accepted February 21. Address correspondence to M.F. (e-mail: michael.fenchel{at}med.uni-tuebingen.de).

In this prospective study, the feasibility of a comprehensive cardiovascular imaging protocol with a dedicated whole-body 1.5-T magnetic resonance (MR) imager with 32 receiver channels in 34 patients with peripheral arterial occlusive disease was evaluated. Informed consent and institutional review board approval were obtained. Three-dimensional MR angiographic data sets were acquired with adapted injection protocol. Cardiac functional imaging and delayed-enhancement imaging were performed, as were fluid-attenuated inversion-recovery imaging of the brain and time-of-flight MR angiography of the intracranial blood vessels. Sensitivity and specificity for depiction of significant vascular stenosis (> 70%) were 96%, with conventional digital subtraction angiography as the standard. Substantial microangiopathic tissue alterations (n = 4) and/or cerebral infarction (n = 4) were diagnosed in seven patients. In seven patients, subendocardial or transmural delayed enhancement was detected in corresponding regions, indicating prior myocardial infarction. Previously unknown findings diagnosed with MR imaging required midterm follow-up or therapy in 24 patients, whereas change of therapy or immediate treatment was necessary in three. For patients suspected of having systemic atherosclerotic disease, comprehensive risk assessment is feasible within 30 minutes.