Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print March 28, 2006, 10.1148/radiol.2392050504
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2392050504v1
239/2/541    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Suzuki, S.
Right arrow Articles by Isshiki, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Suzuki, S.
Right arrow Articles by Isshiki, T.
(Radiology 2006;239:541-546.)
© RSNA, 2006


Technical Developments

Radiosensitive Functional Dye: Clinical Application for Estimation of Patient Skin Dose1

Shigeru Suzuki, MD, Shigeru Furui, MD, Hiroshi Kohtake, MD, Tohru Takeshita, MD, Masatoshi Suzuki, MD, Ken Kozuma, MD, Yoshito Yamamoto, MD and Takaaki Isshiki, MD

1 From the Departments of Radiology (S.S., S.F., H.K., T.T.) and Medicine (M.S., K.K., Y.Y., T.I.), Teikyo University School of Medicine, 2-11-1 Kaga, Itabashi-ku, Tokyo 173-8605, Japan. Received March 26, 2005; revision requested May 25; revision received June 11; final version accepted July 1. Supported in part by Health and Labour Sciences Research Grants for Research on Pharmaceutical and Medical Safety from the Ministry of Health, Labour and Welfare, Tokyo, Japan. Address correspondence to S.S. (e-mail: s-suzuki{at}med.teikyo-u.ac.jp).

Institutional review board approval and informed patient consent were obtained. The purpose of the study was to prospectively evaluate the use of radiosensitive indicators to estimate patient entrance skin dose (ESD). Forty-six patients wore a jacket with 48 or 52 indicators adhered to the back during percutaneous coronary interventions; they had eight additional indicators on their upper arms. The patients' ESDs were calculated according to the change in color of the indicators. There were good correlations between the ESDs estimated by using color measurements performed with an optical instrument and those estimated at visual observation (P < .001) and between the ESDs estimated by using a thermoluminescent dosimeter and those estimated by using color measurements (P < .001). The radiosensitive indicator method seems to be useful for estimating ESDs and their distribution during percutaneous coronary intervention; however, visual observation is reliable for estimating doses of up to 5 Gy only.

© RSNA, 2006




This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
S. Suzuki, S. Furui, Y. Matsumaru, S. Nobuyuki, M. Ebara, T. Abe, and D. Itoh
Patient Skin Dose during Neuroembolization by Multiple-Point Measurement Using a Radiosensitive Indicator
AJNR Am. J. Neuroradiol., June 1, 2008; 29(6): 1076 - 1081.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2006 by the Radiological Society of North America.