Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print August 23, 2006, 10.1148/radiol.2411051271
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2411051271v1
241/1/116    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Laeseke, P. F.
Right arrow Articles by Lee, F. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Laeseke, P. F.
Right arrow Articles by Lee, F. T., Jr
(Radiology 2006;241:116-124.)
© RSNA, 2006


Experimental Studies

Multiple-Electrode Radiofrequency Ablation Creates Confluent Areas of Necrosis: In Vivo Porcine Liver Results1

Paul F. Laeseke, BS, Lisa A. Sampson, CVT, Dieter Haemmerich, PhD, Christopher L. Brace, PhD, Jason P. Fine, ScD, Tina M. Frey, RT(R), Thomas C. Winter, III, MD and Fred T. Lee, Jr, MD

1 From the Departments of Radiology (P.F.L., L.A.S., C.L.B., T.M.F., T.C.W., F.T.L.) and Biostatistics and Medical Informatics (J.P.F.), University of Wisconsin, Box 3252, Clinical Science Center-E3, 600 Highland Ave, Madison, WI 53792; and Department of Pediatrics, Medical University of South Carolina, Charleston, SC (D.H.). Received July 29, 2005; revision requested October 4; revision received December 5; accepted January 10, 2006; final version accepted February 1. Supported in part by Valleylab, Boulder, Colo. Address correspondence to P.F.L. (e-mail: plaeseke{at}wisc.edu).

Purpose: To prospectively evaluate, in vivo in pigs, an impedance-based multiple-electrode radiofrequency (RF) ablation system for creation of confluent areas of hepatic coagulation.

Materials and Methods: The study was preapproved by the institutional research animal care and use committee. A prototype multiple-electrode RF system that enables switching between three electrically independent electrodes at impedance spikes was created. Forty-two coagulation zones (18 with single, 12 with cluster, and 12 with multiple [three single electrodes spaced 2 cm apart] electrodes) were created at laparotomy in 15 female pigs. Half the ablations were performed for 12 minutes, and half were performed for 16 minutes. The coagulation zones were excised and sliced into approximately 3-mm sections for measurement. Analysis of variance and two-sample t tests (with Bonferroni correction, {alpha} = .0033) were used to assess for differences between groups.

Results: At 12 minutes, the mean multiple-electrode coagulation was significantly larger than the mean single-electrode coagulation (minimum diameter, 2.8 vs 1.6 cm; maximum diameter, 4.2 vs 2.0 cm; volume, 22.1 vs 6.7 cm3; P < .0033 for all comparisons). The mean maximum diameter achieved at 12 minutes with multiple electrodes was significantly larger than that achieved with the cluster electrode (4.2 vs 2.9 cm, P = .02). At 16 minutes, the mean multiple-electrode coagulation (minimum diameter, 3.2 cm; maximum diameter, 4.2 cm; volume, 29.1 cm3) was significantly larger than the mean single-electrode (minimum diameter, 1.7 cm; maximum diameter, 2.2 cm; volume, 7.1 cm3; P < .0033 for all comparisons) and cluster-electrode (minimum diameter: 2.3 cm, P = .007; maximum diameter: 3.2 cm, P = .005; volume: 13.1 cm3, P = .001) coagulations.

Conclusion: Compared with the single and cluster systems used as controls, the multiple-electrode RF ablation system enabled the creation of significantly larger coagulation zones.

© RSNA, 2006




This article has been cited by other articles:


Home page
RadiologyHome page
C. L. Brace, P. F. Laeseke, L. A. Sampson, T. M. Frey, D. W. van der Weide, and F. T. Lee Jr
Microwave Ablation with Multiple Simultaneously Powered Small-gauge Triaxial Antennas: Results from an in Vivo Swine Liver Model
Radiology, July 1, 2007; 244(1): 151 - 156.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. F. Laeseke, T. M. Frey, C. L. Brace, L. A. Sampson, T. C. Winter III, J. R. Ketzler, and F. T. Lee Jr.
Multiple-Electrode Radiofrequency Ablation of Hepatic Malignancies: Initial Clinical Experience
Am. J. Roentgenol., June 1, 2007; 188(6): 1485 - 1494.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2006 by the Radiological Society of North America.