Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print September 11, 2006, 10.1148/radiol.2412051384
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2412051384v1
241/2/378    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Leschka, S.
Right arrow Articles by Alkadhi, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Leschka, S.
Right arrow Articles by Alkadhi, H.
(Radiology 2006;241:378-385.)
© RSNA, 2006


Cardiac Imaging

Noninvasive Coronary Angiography with 64-Section CT: Effect of Average Heart Rate and Heart Rate Variability on Image Quality1

Sebastian Leschka, MD, Simon Wildermuth, MD, Thomas Boehm, MD, Lotus Desbiolles, MD, Lars Husmann, MD, André Plass, MD, Pascal Koepfli, MD, Tiziano Schepis, MD, Borut Marincek, MD, Philipp A. Kaufmann, MD and Hatem Alkadhi, MD

1 From the Institute of Diagnostic Radiology (S.L., S.W., T.B., L.D., B.M., H.A.), the Clinic for Cardiovascular Surgery (A.P.), and the Cardiovascular Center (P.K., T.S., P.A.K.), University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich, Switzerland; and the Center for Integrative Human Physiology, University of Zurich (P.A.K.). Received August 17, 2005; revision requested October 20; revision received December 29; final version accepted February 1, 2006. Supported by the National Center of Competence in Research, Computer Aided and Image Guided Medical Interventions of the Swiss National Science Foundation and by the Georg und Bertha Schwyzer-Winiker-Stiftung, Zurich, Switzerland. Address correspondence to H.A. (e-mail: hatem.alkadhi{at}usz.ch).

Purpose: To evaluate prospectively the effect of average heart rate and heart rate variability on image quality at 64-section computed tomographic (CT) coronary angiography.

Materials and Methods: The study protocol had local ethics committee approval; written informed consent was obtained. There were 125 patients (45 women, 80 men; mean age, 59.9 years ± 12.9 [standard deviation]; 79 receiving ß-blockers) who underwent 64-section CT coronary angiography with retrospective electrocardiographic gating. Data sets were reconstructed in 5% steps from 20% to 80% of R-R interval. Heart rate variability was calculated as 1 standard deviation from mean rate during scanning. Two observers rated image quality of each coronary segment at least 1.5-mm diameter (1 = no motion artifacts, 5 = not evaluative). Repeated analysis of variance measurements were performed to evaluate quantitative parameters. Pearson correlation analysis was performed to compare image quality in each patient with average heart rate and heart rate variability.

Results: Average heart rate was 63.3 beats per minute ± 13.1, with variability of 3.2 beats per minute ± 2.1. Diagnostic image quality (score ≤ 3) was attained in 1821 of 1836 segments at the best reconstruction interval. There was no correlation between mean heart rate and image quality for all segments of the right coronary and left anterior descending arteries, but there was a significant correlation for left circumflex artery (r = 0.33, P < .05). Heart rate variability was correlated with image quality overall (r = 0.75, P < .001) and for each coronary artery. Heart rate was less variable and image quality was better (P < .05) in patients receiving ß-blockers. Best image quality was obtained in diastole with heart rate less than 80 beats per minute and in systole with faster heart rate.

Conclusion: Coronary angiography with 64-section CT provides diagnostic image quality within a wide range of heart rates. Reducing average heart rate and heart rate variability is beneficial for reducing artifacts.

© RSNA, 2006




This article has been cited by other articles:


Home page
RadiologyHome page
S. Baumuller, S. Leschka, L. Desbiolles, P. Stolzmann, H. Scheffel, B. Seifert, B. Marincek, and H. Alkadhi
Dual-Source versus 64-Section CT Coronary Angiography at Lower Heart Rates: Comparison of Accuracy and Radiation Dose
Radiology, July 8, 2009; (2009) 2531090065.
[Abstract] [Full Text]


Home page
Br. J. Radiol.Home page
W T ROBERTS, A R WRIGHT, J B TIMMIS, and A D TIMMIS
Safety and efficacy of a rate control protocol for cardiac CT
Br. J. Radiol., April 1, 2009; 82(976): 267 - 271.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
L. Husmann, B. A. Herzog, O. Gaemperli, F. Tatsugami, N. Burkhard, I. Valenta, P. Veit-Haibach, C. A. Wyss, U. Landmesser, and P. A. Kaufmann
Diagnostic accuracy of computed tomography coronary angiography and evaluation of stress-only single-photon emission computed tomography/computed tomography hybrid imaging: comparison of prospective electrocardiogram-triggering vs. retrospective gating
Eur. Heart J., March 1, 2009; 30(5): 600 - 607.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
L ROMANO, L GRAZIOLI, L BONOMO, J-R XU, K-M CHEN, R DORE, A VANZULLI, and C CATALANO
Enhancement and safety of iomeprol-400 and iodixanol-320 in patients undergoing abdominal multidetector CT
Br. J. Radiol., March 1, 2009; 82(975): 204 - 211.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
B. A. Herzog, L. Husmann, N. Burkhard, O. Gaemperli, I. Valenta, F. Tatsugami, C. A. Wyss, U. Landmesser, and P. A. Kaufmann
Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience
Eur. Heart J., December 2, 2008; 29(24): 3037 - 3042.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Matsumoto, T. Kondo, S. Watanabe, R. Kikumoto, T. Shimada, Y. Hiraoka, and K. Ueda
ECG-Edited Middiastolic Phase Reconstruction Improves Image Quality at 64-MDCT Coronary Angiography of Patients with Atrial Fibrillation
Am. J. Roentgenol., December 1, 2008; 191(6): 1659 - 1666.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. Stolzmann, H. Scheffel, S. Leschka, A. Plass, S. Baumuller, B. Marincek, and H. Alkadhi
Influence of Calcifications on Diagnostic Accuracy of Coronary CT Angiography Using Prospective ECG Triggering
Am. J. Roentgenol., December 1, 2008; 191(6): 1684 - 1689.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. Stolzmann, S. Leschka, H. Scheffel, T. Krauss, L. Desbiolles, A. Plass, M. Genoni, T. G. Flohr, S. Wildermuth, B. Marincek, et al.
Dual-Source CT in Step-and-Shoot Mode: Noninvasive Coronary Angiography with Low Radiation Dose
Radiology, October 1, 2008; 249(1): 71 - 80.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S Leschka, H Scheffel, L Desbiolles, A Plass, O Gaemperli, P Stolzmann, M Genoni, T Luescher, B Marincek, P Kaufmann, et al.
Combining dual-source computed tomography coronary angiography and calcium scoring: added value for the assessment of coronary artery disease
Heart, September 1, 2008; 94(9): 1154 - 1161.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. Bastarrika, C. N. De Cecco, M. Arraiza, S. Mastrobuoni, J. C. Pueyo, M. Ubilla, and G. Rabago
Dual-Source CT for Visualization of the Coronary Arteries in Heart Transplant Patients with High Heart Rates
Am. J. Roentgenol., August 1, 2008; 191(2): 448 - 454.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
O. Gaemperli, T. Schepis, I. Valenta, P. Koepfli, L. Husmann, H. Scheffel, S. Leschka, F. R. Eberli, T. F. Luscher, H. Alkadhi, et al.
Functionally Relevant Coronary Artery Disease: Comparison of 64-Section CT Angiography with Myocardial Perfusion SPECT
Radiology, August 1, 2008; 248(2): 414 - 423.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
N. Hirai, J. Horiguchi, C. Fujioka, M. Kiguchi, H. Yamamoto, N. Matsuura, T. Kitagawa, H. Teragawa, N. Kohno, and K. Ito
Prospective versus Retrospective ECG-gated 64-Detector Coronary CT Angiography: Assessment of Image Quality, Stenosis, and Radiation Dose
Radiology, August 1, 2008; 248(2): 424 - 430.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
V. Cheng, A. Gutstein, A. Wolak, Y. Suzuki, D. Dey, H. Gransar, L. E.J. Thomson, S. W. Hayes, J. D. Friedman, and D. S. Berman
Moving beyond binary grading of coronary arterial stenoses on coronary computed tomographic angiography insights for the imager and referring clinician.
J. Am. Coll. Cardiol. Img., July 1, 2008; 1(4): 460 - 471.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Oncel, G. Oncel, A. Tastan, and B. Tamci
Evaluation of Coronary Stent Patency and In-Stent Restenosis with Dual-Source CT Coronary Angiography Without Heart Rate Control
Am. J. Roentgenol., July 1, 2008; 191(1): 56 - 63.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
N. Matsuura, J. Horiguchi, H. Yamamoto, N. Hirai, T. Tonda, N. Kohno, and K. Ito
Optimal Cardiac Phase for Coronary Artery Calcium Scoring on Single-Source 64-MDCT Scanner: Least Interscan Variability and Least Motion Artifacts
Am. J. Roentgenol., June 1, 2008; 190(6): 1561 - 1568.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Leschka, H. Scheffel, L. Husmann, O. Gamperli, B. Marincek, P. A. Kaufmann, and H. Alkadhi
Effect of Decrease in Heart Rate Variability on the Diagnostic Accuracy of 64-MDCT Coronary Angiography
Am. J. Roentgenol., June 1, 2008; 190(6): 1583 - 1590.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. Brodoefel, C. Burgstahler, I. Tsiflikas, A. Reimann, S. Schroeder, C. D. Claussen, M. Heuschmid, and A. F. Kopp
Dual-Source CT: Effect of Heart Rate, Heart Rate Variability, and Calcification on Image Quality and Diagnostic Accuracy
Radiology, May 1, 2008; 247(2): 346 - 355.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
H. Alkadhi, H. Scheffel, L. Desbiolles, O. Gaemperli, P. Stolzmann, A. Plass, G. W. Goerres, T. F. Luescher, M. Genoni, B. Marincek, et al.
Dual-source computed tomography coronary angiography: influence of obesity, calcium load, and heart rate on diagnostic accuracy
Eur. Heart J., March 2, 2008; 29(6): 766 - 776.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll Cardiol ImgHome page
S. Achenbach, U. Ropers, A. Kuettner, K. Anders, T. Pflederer, S. Komatsu, W. Bautz, W. G. Daniel, and D. Ropers
Randomized comparison of 64-slice single- and dual-source computed tomography coronary angiography for the detection of coronary artery disease.
J. Am. Coll. Cardiol. Img., March 1, 2008; 1(2): 177 - 186.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. T. Johnson, J. Eng, H. K. Pannu, and E. K. Fishman
64-MDCT Angiography of the Coronary Arteries: Nationwide Survey of Patient Preparation Practice
Am. J. Roentgenol., March 1, 2008; 190(3): 743 - 747.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. P. Earls, E. L. Berman, B. A. Urban, C. A. Curry, J. L. Lane, R. S. Jennings, C. C. McCulloch, J. Hsieh, and J. H. Londt
Prospectively Gated Transverse Coronary CT Angiography versus Retrospectively Gated Helical Technique: Improved Image Quality and Reduced Radiation Dose
Radiology, March 1, 2008; 246(3): 742 - 753.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
S. Schroeder, S. Achenbach, F. Bengel, C. Burgstahler, F. Cademartiri, P. de Feyter, R. George, P. Kaufmann, A. F. Kopp, J. Knuuti, et al.
Cardiac computed tomography: indications, applications, limitations, and training requirements: Report of a Writing Group deployed by the Working Group Nuclear Cardiology and Cardiac CT of the European Society of Cardiology and the European Council of Nuclear Cardiology
Eur. Heart J., February 2, 2008; 29(4): 531 - 556.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
L. Husmann, I. Valenta, O. Gaemperli, O. Adda, V. Treyer, C. A. Wyss, P. Veit-Haibach, F. Tatsugami, G. K. von Schulthess, and P. A. Kaufmann
Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
Eur. Heart J., January 2, 2008; 29(2): 191 - 197.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. Oncel, G. Oncel, and A. Tastan
Effectiveness of Dual-Source CT Coronary Angiography for the Evaluation of Coronary Artery Disease in Patients with Atrial Fibrillation: Initial Experience
Radiology, December 1, 2007; 245(3): 703 - 711.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Seifarth, S. Wienbeck, M. Pusken, K.-U. Juergens, D. Maintz, C. Vahlhaus, W. Heindel, and R. Fischbach
Optimal Systolic and Diastolic Reconstruction Windows for Coronary CT Angiography Using Dual-Source CT
Am. J. Roentgenol., December 1, 2007; 189(6): 1317 - 1323.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. Husmann, S. Leschka, L. Desbiolles, T. Schepis, O. Gaemperli, B. Seifert, P. Cattin, T. Frauenfelder, T. G. Flohr, B. Marincek, et al.
Coronary Artery Motion and Cardiac Phases: Dependency on Heart Rate Implications for CT Image Reconstruction
Radiology, November 1, 2007; 245(2): 567 - 576.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Matt, H. Scheffel, S. Leschka, T. G. Flohr, B. Marincek, P. A. Kaufmann, and H. Alkadhi
Dual-Source CT Coronary Angiography: Image Quality, Mean Heart Rate, and Heart Rate Variability
Am. J. Roentgenol., September 1, 2007; 189(3): 567 - 573.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. J. M. Kroft, A. de Roos, and J. Geleijns
Artifacts in ECG-Synchronized MDCT Coronary Angiography
Am. J. Roentgenol., September 1, 2007; 189(3): 581 - 591.
[Abstract] [Full Text] [PDF]