Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print October 25, 2006, 10.1148/radiol.2413051522
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow AVI Movies
Right arrow All Versions of this Article:
2413051522v1
241/3/718    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jahnke, C.
Right arrow Articles by Nagel, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jahnke, C.
Right arrow Articles by Nagel, E.
(Radiology 2006;241:718-728.)
© RSNA, 2006


Cardiac Imaging

Accelerated 4D Dobutamine Stress MR Imaging with k-t BLAST: Feasibility and Diagnostic Performance1

Cosima Jahnke, MD, Ingo Paetsch, MD, Rolf Gebker, MD, Axel Bornstedt, PhD, Eckart Fleck, MD and Eike Nagel, MD

1 From the Department of Internal Medicine/Cardiology, German Heart Institute Berlin, Augustenburger Platz 1, 13353 Berlin, Germany. Received September 12, 2005; revision requested November 10; revision received December 13; accepted January 11, 2006; final version accepted February 9. Address correspondence to C.J. (e-mail: jahnke{at}dhzb.de).

Purpose: To prospectively determine feasibility and diagnostic performance (with angiography as reference standard) of k-space and time (k-t) broad-use linear acquisition speed-up technique (k-t BLAST) cine imaging during dobutamine stress for identification of inducible cardiac wall motion abnormalities.

Materials and Methods: The study was conducted according to standards of the Charité and Virchow-Klinikum Ethics Committee. Patients gave written consent. Dobutamine stress magnetic resonance (MR) imaging was conducted in 65 patients (mean age, 63 years ± 9 [standard deviation]; 49 men) with conventional cine steady-state free precession (SSFP). Accelerated four-dimensional (4D) k-t BLAST single-breath-hold imaging with complete left ventricular (LV) coverage was also performed at rest and during stress. For the cine SSFP and accelerated cine techniques, duration of imaging at rest and LV end-diastolic volume and ejection fraction were assessed. Segmental agreement for resting and inducible wall motion abnormalities was determined. In a subgroup (n = 40), direct comparison between SSFP and accelerated cine was performed for coronary stenosis detection. A paired Student t test was used to assess significance of continuous variables. Pearson correlation was used to test correlation between the techniques. Sensitivity, specificity, and diagnostic accuracy were calculated (standard definitions). For quantitative measurement of agreement, Cohen {kappa} was applied.

Results: For accelerated cine, imaging duration at rest was shortened by 40%. Correlations between cine SSFP and accelerated cine for LV parameters were 135 mL ± 37 versus 129 mL ± 31 (r = 0.89) for end-diastolic volume and 59% ± 8 versus 58% ± 7 (r = 0.95) for ejection fraction. {kappa} Values for segmental wall motion at rest and stress ranged from 0.77 to 0.91. Sensitivity, specificity, and diagnostic accuracy for coronary stenosis (≥50%) detection based on arterial territory were 82%, 87%, and 86%, respectively, for cine SSFP and 82%, 86%, and 85%, respectively, for accelerated cine imaging.

Conclusion: Accelerated 4D k-t BLAST wall motion imaging at rest and at dobutamine stress is rapid and feasible; LV measurements were nearly identical between the imaging approaches. Segmental wall motion analysis at rest and at stress show excellent agreement and reliable depiction of myocardial territories supplied by coronary arteries with 50% or more luminal narrowing.

Supplemental material: http://radiology.rsnajnls.org/cgi/content/full/2413051522/DC1

© RSNA, 2006




This article has been cited by other articles:


Home page
HeartHome page
W P Bandettini and A E Arai
Advances in clinical applications of cardiovascular magnetic resonance imaging
Heart, November 1, 2008; 94(11): 1485 - 1495.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. Gebker, C. Jahnke, I. Paetsch, B. Schnackenburg, S. Kozerke, A. Bornstedt, E. Fleck, and E. Nagel
MR Myocardial Perfusion Imaging with k-Space and Time Broad-Use Linear Acquisition Speed-up Technique: Feasibility Study
Radiology, December 1, 2007; 245(3): 863 - 871.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
K. R. Nandalur, B. A. Dwamena, A. F. Choudhri, M. R. Nandalur, and R. C. Carlos
Diagnostic Performance of Stress Cardiac Magnetic Resonance Imaging in the Detection of Coronary Artery Disease: A Meta-Analysis
J. Am. Coll. Cardiol., October 2, 2007; 50(14): 1343 - 1353.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. J. Gibbons, P. A. Araoz, and E. E. Williamson
The Year in Cardiac Imaging
J. Am. Coll. Cardiol., September 4, 2007; 50(10): 988 - 1003.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2006 by the Radiological Society of North America.