Special Reports |
1 From the Department of Radiation Oncology & Biology, University of Oxford (K.R.), Gray Cancer Institute (K.R., S.B.); Department of Medical Physics (J.S.); and Paul Strickland Scanner Centre (P.F., V.G.), Mount Vernon Hospital, Rickmansworth Road, Northwood, Middlesex HA6 2JR, England. Received January 29, 2006; revision requested March 7; revision received April 5; final version accepted June 1. Funded by the Royal College of Radiologists/Society and College of Radiographers and the Gray Laboratory Cancer Research Trust. Address correspondence to K.R. (e-mail: rothkamm{at}gci.ac.uk).
Purpose: To prospectively determine if
H2AX (phosphorylated form of H2AX histone variant)-based visualization and quantification of DNA damage induced in peripheral blood mononuclear cells (PBMCs) can be used to estimate the radiation dose received by adult patients who undergo multidetector computed tomography (CT).
Materials and Methods: After institutional review board approval and written informed patient consent were obtained, eight women and five men (mean age, 63.8 years) who would be undergoing chest-abdominal-pelvic CT or chest CT only were recruited. Venous blood samples obtained before scanning were exposed to different radiation doses in vitro and incubated for 530 minutes to obtain reference values of
H2AX focus yield. Additional blood samples were taken 530 minutes after CT. Leukocytes were isolated, fixed, and stained for
H2AX expression. The
H2AX focus yields were determined with fluorescence microscopy, and the radiation doses delivered during CT were estimated by comparing post-CT focus yields with in vitro pre-CT focus yields. These CT radiation doses were compared with doses calculated by using phantom dosimetry and Monte Carlo data sets. Data were analyzed by using linear regression, the dispersion index test, and the contaminated Poisson method.
Results: Compared with the
H2AX focus yields in blood samples taken before CT (0.06 focus per cell ± 0.01 [mean ± standard error of mean]), the yields in blood samples taken 5 minutes after chest-abdominal-pelvic CT (0.52 focus per cell ± 0.02) were 810-fold higher and corresponded to a mean radiation dose of 16.4 mGy (95% confidence interval: 15.1, 17.7). The mean yield of 0.24 focus per cell ± 0.04 in one patient after chest CT corresponded to a mean radiation dose of 6.3 mGy ± 1.4. In comparison, phantom dosimetrycalculated total blood doses were 13.85 mGy with whole-body CT and 5.16 mGy with chest CT.
Conclusion:
H2AX focus yield in blood cells may be a useful quantitative biomarker of human low-level radiation exposure.
© RSNA, 2007