Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2422060153
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Heyer, C. M.
Right arrow Articles by Nicolas, V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Heyer, C. M.
Right arrow Articles by Nicolas, V.
(Radiology 2007;242:542-549.)
© RSNA, 2007


Pediatric Imaging

Tracheobronchial Anomalies and Stenoses: Detection with Low-Dose Multidetector CT with Virtual Tracheobronchoscopy—Comparison with Flexible Tracheobronchoscopy1

Christoph M. Heyer, MD, Thomas G. Nuesslein, MD, David Jung, MD, Soeren A. Peters, MD, Stefan P. Lemburg, MD, Christian H. L. Rieger, MD and Volkmar Nicolas, MD

1 From the Institute of Diagnostic Radiology, Interventional Radiology and Nuclear Medicine, BG Clinics Bergmannsheil, Ruhr-University of Bochum, Buerkle-de-la-Camp Platz 1, D-44789 Bochum, Germany (C.M.H., S.A.P., S.P.L., V.N.); and Children's University Hospital, St Josef Hospital, Ruhr-University of Bochum, Germany (T.G.N., D.J., C.H.L.R.). Received January 26, 2006; revision requested March 24; revision received April 3; accepted May 9; final version accepted June 8. Address correspondence to C.M.H. (e-mail: christoph.heyer{at}rub.de).

Purpose: To prospectively assess the sensitivity and specificity of low-dose multidetector computed tomography (CT) with virtual tracheobronchoscopy (VT) for evaluation of suspected airway stenoses and/or abnormalities by using flexible tracheobronchoscopy (FT) as the reference standard.

Materials and Methods: The study was approved by the local ethics committee; parental consent was obtained. Forty-five patients with clinically and/or radiographically suspected tracheobronchial stenosis and/or anomaly underwent FT and contrast material–enhanced single-phase multidetector CT with VT. CT was performed with an age- and weight-adjusted low-dose protocol: 120 or 80 kV; 120 or 60 mA; collimation, 1.5 or 0.75 mm; gantry rotation, 0.5 second. Mean effective dose was calculated for all examinations. Postprocessing was performed with surface rendering of VT images and multiplanar reformations. CT images were analyzed in consensus by two radiologists who were blinded to FT results. Statistical analysis was performed with 2 x 2 contingency tables; 95% confidence intervals (CIs) were calculated with the Blyth-Still-Casella procedure.

Results: Mean patient age was 4.4 years (range, 2 months to 16 years; 53% male patients). Tracheobronchial narrowing and/or abnormality were depicted at FT in 38 of 45 patients. In 33 of 38 patients, multidetector CT with VT depicted a tracheobronchial narrowing and/or anomaly. In 10 of 38 patients, tracheobronchial stenosis was induced by vascular anomalies. Five patients with normal findings at multidetector CT with VT had tracheobronchomalacia with inspiratory airway stenosis at FT. Sensitivity and specificity of CT with VT were 86.8% (95% CI: 73.3%, 94.7%) and 85.7% (95% CI: 44.6%, 99.3%), respectively. Positive and negative predictive values were 97.1% (95% CI: 84.9%, 99.9%) and 54.5% (95% CI: 25.0%, 80.0%), respectively. Overall accuracy was 86.7% (95% CI: 74.3%, 94.0%). Mean effective dose was 1.1 mSv (range, 0.5–1.8 mSv).

Conclusion: Multidetector CT with VT with a low-dose protocol had high sensitivity and specificity for depiction of tracheobronchial narrowings and/or anomalies. However, tracheal narrowing due to tracheobronchomalacia was difficult to diagnose at single-phase multidetector CT with VT.