Thoracic Imaging |
1 From the Departments of Radiology (P.A.A.) and Health Sciences Research, Division of Biostatistics (J.R.H., W.S.H., J.N.M.), Mayo Clinic, 200 First St SW, Rochester, MN 55905; and Scottsdale Medical Imaging, Scottsdale, Ariz (M.B.G.). Received August 26, 2005; revision requested November 2; revision received February 23, 2006; accepted April 3; final version accepted, June 8. Address correspondence to P.A.A. (e-mail: paraoz{at}mayo.edu).
Purpose: To retrospectively determine whether three computed tomographic (CT) findingsventricular septal bowing (VSB), ratio between the diameters of right ventricle (RV) and left ventricle (LV), and embolic burdenare associated with short-term death, defined as in-hospital death or death within 30 days of CT, whichever was longer, due to acute pulmonary embolism (PE).
Materials and Methods: Institutional Review Board approval was obtained, and patient information was reviewed in compliance with HIPAA regulations. A total of 1193 patients with CT scans positive for PE from January 1, 1997, to December 31, 2002, who had given authorization for retrospective research were included. Scans were independently reviewed by two observers. CT findings were compared with risk of death by using univariate analysis (
2 statistic) and multivariate logistic regression. Interobserver variability (
statistic or intraclass correlation coefficient), sensitivity, and specificity of CT findings for predicting death were calculated. A third observer reviewed discrepant cases post hoc.
Results: Fifty-four percent of patients were women and 46% were men (mean age, 63 years ± 16). For observer 1, VSB was associated with death in univariate (odds ratio [OR], 1.98; P = .04) and multivariate modeling (OR, 1.97; P = .05). Interobserver variability was only fair (
= 0.54) for VSB, and observer 2 found no association with death (OR, 1.52; P = .22). For both observers, VSB had low sensitivity (21% and 18%) and high specificity (88% and 87%) for predicting death. Neither RV/LV diameter ratio nor embolic burden was associated with increased risk of death. For observer 3, VSB was associated with death in univariate (OR, 2.10; P = .05) and multivariate analyses (OR, 2.18; P = .05).
Conclusion: CT-depicted VSB is predictive of death due to PE, but with low sensitivity and high interobserver variability. RV/LV diameter ratio and embolic burden are not associated with short-term death due to PE.
© RSNA, 2007
This article has been cited by other articles:
![]() |
I. Ocak and C. Fuhrman CT Angiography Findings of the Left Atrium and Right Ventricle in Patients with Massive Pulmonary Embolism Am. J. Roentgenol., October 1, 2008; 191(4): 1072 - 1076. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |