Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print April 19, 2007, 10.1148/radiol.2433060838
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2433060838v1
243/3/670    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pediconi, F.
Right arrow Articles by Passariello, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pediconi, F.
Right arrow Articles by Passariello, R.
(Radiology 2007;243:670-680.)
© RSNA, 2007


Breast Imaging

Contrast-enhanced MR Mammography for Evaluation of the Contralateral Breast in Patients with Diagnosed Unilateral Breast Cancer or High-Risk Lesions1

Federica Pediconi, MD, Carlo Catalano, MD, Antonella Roselli, MD, Simona Padula, MD, Fiorella Altomari, MD, Enrica Moriconi, MD, Anna Maria Pronio, MD, Miles A. Kirchin, PhD, and Roberto Passariello, MD

1 From the Departments of Radiological Sciences (F.P., C.C., A.R., S.P., F.A., E.M., R.P.) and Surgery (A.M.P.), University of Rome "La Sapienza," Viale Regina Elena, 324, 00161 Rome, Italy; and Department of Worldwide Medical Affairs, Bracco Imaging, Milan, Italy (M.A.K.). Received May 13, 2006; revision requested July 13; revision received July 24; accepted August 23; final version accepted October 5. Address correspondence to F.P. (e-mail: federica.pediconi{at}uniroma1.it).

Purpose: To prospectively evaluate accuracy of gadobenate dimeglumine–enhanced magnetic resonance (MR) mammography for depiction of synchronous contralateral breast cancer in patients with newly diagnosed unilateral breast cancer or high-risk lesions, with histologic analysis or follow-up as reference.

Materials and Methods: The study had ethics committee approval; all patients provided written informed consent. One hundred eighteen consecutive women (mean age, 52 years) with unilateral breast cancer or high-risk lesions and negative findings in the contralateral breast at physical examination, ultrasonography, and conventional mammography underwent gadobenate dimeglumine–enhanced 1.5-T MR mammography. Transverse three-dimensional T1-weighted gradient-echo images were acquired before and at 0, 2, 4, 6, and 8 minutes after gadobenate dimeglumine administration (0.1 mmol per kilogram body weight). Breast Imaging Reporting and Data System (BI-RADS) was used to categorize breast density and the level of suspicion for malignant contralateral breast lesions. Results were compared with histologic findings. Sensitivity, specificity, accuracy, and positive and negative predictive values for contrast-enhanced MR mammography were evaluated.

Results: Contrast-enhanced MR mammography revealed contralateral lesions in 28 (24%) of 118 patients. Twenty-four lesions were detected in patients with dense breasts (BI-RADS breast density category III or IV). Lesions in eight (29%) of 28 patients were BI-RADS category 4; patients underwent biopsy. Lesions in 20 (71%) patients were BI-RADS category 5; patients underwent surgery. At histologic analysis, 22 lesions were confirmed as malignant; six lesions were fibroadenomas. No false-negative lesions were detected; none of the fibroadenomas were BI-RADS category 5. The sensitivity, specificity, accuracy, and positive and negative predictive values of contrast-enhanced MR mammography for depiction of malignant or high-risk contralateral lesions were 100%, 94%, 95%, 79%, and 100%, respectively. Follow-up findings (12–24 months) confirmed absence of contralateral lesions in 90 of 118 patients with negative contrast-enhanced MR mammographic findings in the contralateral breast.

Conclusion: Contrast-enhanced MR mammography is accurate for detection of synchronous contralateral cancer or high-risk lesions in patients with newly diagnosed breast cancer or high-risk lesions.

© RSNA, 2007




This article has been cited by other articles:


Home page
Jpn J Clin OncolHome page
N. Taira, S. Ohsumi, D. Takabatake, F. Hara, S. Takashima, K. Aogi, S. Takashima, T. Inoue, S. Sugata, and R. Nishimura
Contrast-enhanced CT Evaluation of Clinically and Mammographically Occult Multiple Breast Tumors in Women with Unilateral Early Breast Cancer
Jpn. J. Clin. Oncol., June 1, 2008; 38(6): 419 - 425.
[Abstract] [Full Text] [PDF]


Home page
Ann OncolHome page
N. Hoogerbrugge, Y. J. L. Kamm, P. Bult, K. M. Landsbergen, E. M. H. F. Bongers, H. G. Brunner, H. J. Bonenkamp, J. A. de Hullu, M. J. L. Ligtenberg, and C. Boetes
The impact of a false-positive MRI on the choice for mastectomy in BRCA mutation carriers is limited
Ann. Onc., April 1, 2008; 19(4): 655 - 659.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
S. Orel
Who Should Have Breast Magnetic Resonance Imaging Evaluation?
J. Clin. Oncol., February 10, 2008; 26(5): 703 - 711.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. J. Kim, E.-K. Kim, J. Y. Kwak, B.-W. Park, S.-I. Kim, J. Sohn, and K. K. Oh
Role of Sonography in the Detection of Contralateral Metachronous Breast Cancer in an Asian Population
Am. J. Roentgenol., February 1, 2008; 190(2): 476 - 480.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2007 by the Radiological Society of North America.