Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2443060582
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, V. S.
Right arrow Articles by Oesingmann, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, V. S.
Right arrow Articles by Oesingmann, N.
(Radiology 2007;244:692-705.)
© RSNA, 2007


Special Reviews

Body and Cardiovascular MR Imaging at 3.0 T1

Vivian S. Lee, MD, PhD, MBA, Elizabeth M. Hecht, MD, Bachir Taouli, MD, Qun Chen, PhD, Keyma Prince, BS, and Niels Oesingmann, PhD 2

1 From the Department of Radiology, New York University Medical Center, 530 First Ave, New York, NY 10016. Received March 31, 2006; revision requested May 31; revision received July 19; accepted August 23; final version accepted November 11; final review and update by V.S.L April 6, 2007. Address correspondence to V.S.L. (e-mail: vivian.lee{at}med.nyu.edu).

Potential advantages of magnetic resonance (MR) imaging at 3 T include higher signal-to-noise ratios, better image contrast, particularly in gadolinium-enhanced applications, and better spectral separation for spectroscopic applications. In terms of clinical imaging, these advantages can mean higher-spatial-resolution images, faster imaging, and improved MR spectroscopy. However, achieving superior imaging and spectroscopic quality at 3 T can be challenging. This review discusses many of the problems encountered in body and cardiovascular MR imaging at 3 T, such as increased susceptibility, B1 field inhomogeneity, and increased specific absorption rate. The article also considers solutions that are being pursued, such as parallel imaging, variable-rate selective excitation, and variable flip angle sequences. A review of the most commonly used pulse sequences provides practical tips on how these can be optimized for 3-T imaging. In the coming few years, substantial improvements in 3-T technology for clinical imaging and spectroscopy will undoubtedly be seen. An understanding of the basic principles on which these developments are based will help radiologists translate the advances into better imaging studies and, ultimately, better patient care.

© RSNA, 2007




This article has been cited by other articles:


Home page
RadiologyHome page
C. A Yi, K. M. Shin, K. S. Lee, B.-T. Kim, H. Kim, O J. Kwon, J. Y. Choi, and M. J. Chung
Non-Small Cell Lung Cancer Staging: Efficacy Comparison of Integrated PET/CT versus 3.0-T Whole-Body MR Imaging
Radiology, August 1, 2008; 248(2): 632 - 642.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J.-Y. Choi, M.-J. Kim, Y. E. Chung, J. Y. Kim, A. C Jones, J. de Becker, and M. van Cauteren
Abdominal Applications of 3.0-T MR Imaging: Comparative Review versus a 1.5-T System
RadioGraphics, July 1, 2008; 28(4): e30 - e30.