Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print August 23, 2007, 10.1148/radiol.2451062081
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Supplemental Tables
Right arrow All Versions of this Article:
2451062081v1
2451062081v2
245/1/276    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sutter, R.
Right arrow Articles by Willmann, J. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sutter, R.
Right arrow Articles by Willmann, J. K.
(Radiology 2007;245:276-284.)
© RSNA, 2007


Vascular and Interventional Radiology

Assessment of Aortoiliac and Renal Arteries: MR Angiography with Parallel Acquisition versus Conventional MR Angiography and Digital Subtraction Angiography1

Reto Sutter, MD, Daniel Nanz, PhD, Amelie M. Lutz, MD, Thomas Pfammatter, MD, Burkhardt Seifert, PhD, Anja Struwe, RT, Christina Heilmaier, MD, Dominik Weishaupt, MD, Borut Marincek, MD, and Jürgen K. Willmann, MD

1 From the Institute of Diagnostic Radiology, University Hospital Zurich, Zurich, Switzerland (R.S., D.N., A.M.L., T.P., A.S., C.H., D.W., B.M., J.K.W.); Molecular Imaging Program at Stanford, Department of Radiology and Bio-X Program, Stanford University School of Medicine, E 150 Clark Center, 318 Campus Dr, Palo Alto, CA, 94305-5427 (A.M.L., J.K.W.); and Department of Biostatistics, University of Zurich, Zurich, Switzerland (B.S.). From the 2006 RSNA Annual Meeting. Received December 7, 2006; revision requested February 16, 2007; revision received March 1; accepted March 20; final version accepted April 16. J.K.W. supported in part by the Swiss Foundation of Medical-Biological Grants, Novartis Research Foundation, and Swiss Society of Radiology. Address correspondence to J.K.W. (e-mail: willmann{at}stanford.edu).

Purpose: To prospectively compare the image quality, sensitivity, and specificity of three-dimensional gadolinium-enhanced magnetic resonance (MR) angiography accelerated by parallel acquisition (ie, fast MR angiography) with MR angiography not accelerated by parallel acquisition (ie, conventional MR angiography) for assessment of aortoiliac and renal arteries, with digital subtraction angiography (DSA) as the reference standard.

Materials and Methods: The study was approved by the institutional review board; informed consent was obtained from all patients. Forty consecutive patients (33 men, seven women; mean age, 63 years) suspected of having aortoiliac and renal arterial stenoses and thus examined with DSA underwent both fast (mean imaging time, 17 seconds) and conventional (mean imaging time, 29 seconds) MR angiography. The arterial tree was divided into segments for image analysis. Two readers independently evaluated all MR angiograms for image quality, presence of arterial stenosis, and renal arterial variants. Image quality, sensitivity, and specificity were analyzed on per-patient and per-segment bases for multiple comparisons (with Bonferroni correction) and for dependencies between segments (with patient as the primary sample unit). Interobserver agreement was evaluated by using {kappa} statistics.

Results: Overall, the image quality with fast MR angiography was significantly better (P = .001) than that with conventional MR angiography. At per-segment analysis, the image quality of fast MR angiograms of the distal renal artery tended to be better than that of conventional MR angiograms of these vessels. Differences in sensitivity for the detection of arterial stenosis between the two MR angiography techniques were not significant for either reader. Interobserver agreement in the detection of variant renal artery anatomy was excellent with both conventional and fast MR angiography ({kappa} = 1.00).

Conclusion: Fast MR angiography and conventional MR angiography do not differ significantly in terms of arterial stenosis grading or renal arterial variant detection.

Supplemental material: http://radiology.rsnajnls.org/cgi/content/full/2451062081/DC1

© RSNA, 2007







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2007 by the Radiological Society of North America.