|
|
||||||||
Technical Developments |
1 From the Institute of Diagnostic Radiology (L.H., S.L., L.D., T.F., B.M., H.A.) and Cardiovascular Center (T.S., O.G., P.A.K.), University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich, Switzerland; Department of Biostatistics (B.S.) and Center for Integrative Human Physiology (P.A.K.), University of Zurich, Zurich, Switzerland; Computer Vision Laboratory, Swiss Federal Institute of Technology, ETH Zurich, Zurich, Switzerland (P.C.); and Computed Tomography CTE PA, Siemens Medical Solutions, Forchheim, Germany (T.G.F.). From the 2006 RSNA Annual Meeting. Received October 17, 2006; revision requested December 19; revision received January 26, 2007; final version accepted March 7. Supported by the National Center of Competence in Research, Computer Aided and Image Guided Medical Interventions of the Swiss National Science Foundation and by the Georg und Bertha Schwyzer-Winiker Stiftung, Switzerland. Address correspondence to H.A. (e-mail: hatem.alkadhi{at}usz.ch).
This study had institutional review board approval; written informed consent was obtained. The purpose was to prospectively determine the heart rate (HR) dependency of three-dimensional (3D) coronary artery motion by incorporating into analysis the durations of systole and diastole. Thirty patients (seven women, 23 men; mean age, 56.6 years ± 12.7 [standard deviation]; HR: 45–100 beats per minute) underwent electrocardiographically gated 64-section computed tomographic (CT) coronary angiography to determine coronary motion velocities at bifurcation points. Significance of velocity differences (P < .05) was determined by using analysis of variance for repeated measures and Bonferroni post hoc tests. HR dependency was determined by using linear regression analysis. HR significantly affected 3D coronary motion (r = 0.47, P < .009) through nonproportional shortening of systole and diastole (r = –0.82, P < .001), leading to percentage reconstruction interval shifts of coronary velocity troughs and peaks (P < .01). Results suggest that image reconstruction algorithms at CT coronary angiography be adapted to the individual patient's HR.
Supplemental material: http://radiology.rsnajnls.org/cgi/content/full/2451061791/DC1
© RSNA, 2007
This article has been cited by other articles:
![]() |
R. J. Gibbons, P. A. Araoz, and E. E. Williamson The year in cardiac imaging. J. Am. Coll. Cardiol., January 6, 2009; 53(1): 54 - 70. [Full Text] [PDF] |
||||
![]() |
P. Stolzmann, S. Leschka, H. Scheffel, T. Krauss, L. Desbiolles, A. Plass, M. Genoni, T. G. Flohr, S. Wildermuth, B. Marincek, et al. Dual-Source CT in Step-and-Shoot Mode: Noninvasive Coronary Angiography with Low Radiation Dose Radiology, October 1, 2008; 249(1): 71 - 80. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. C. Weustink, N. R. Mollet, F. Pugliese, W. B. Meijboom, K. Nieman, M. H. Heijenbrok-Kal, T. G. Flohr, L. A. E. Neefjes, F. Cademartiri, P. J. de Feyter, et al. Optimal Electrocardiographic Pulsing Windows and Heart Rate: Effect on Image Quality and Radiation Exposure at Dual-Source Coronary CT Angiography Radiology, September 1, 2008; 248(3): 792 - 798. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Husmann, I. Valenta, O. Gaemperli, O. Adda, V. Treyer, C. A. Wyss, P. Veit-Haibach, F. Tatsugami, G. K. von Schulthess, and P. A. Kaufmann Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating Eur. Heart J., January 2, 2008; 29(2): 191 - 197. [Abstract] [Full Text] [PDF] |
||||