Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print October 19, 2007, 10.1148/radiol.2453062116
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2453062116v1
245/3/881    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Honda, O.
Right arrow Articles by Nakamura, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Honda, O.
Right arrow Articles by Nakamura, H.
(Radiology 2007;245:881-887.)
© RSNA, 2007


Thoracic Imaging

Pulmonary Nodules: 3D Volumetric Measurement with Multidetector CT—Effect of Intravenous Contrast Medium1

Osamu Honda, MD, PhD, Takeshi Johkoh, MD, PhD, Hiromitsu Sumikawa, MD, Atsuo Inoue, MD, PhD, Noriyuki Tomiyama, MD, PhD, Naoki Mihara, MD, PhD, Yuka Fujita, MD, Mitsuko Tsubamoto, MD, PhD, Masahiro Yanagawa, MD, Tadahisa Daimon, MD, Javzandulam Natsag, MD, and Hironobu Nakamura, MD, PhD

1 From the Departments of Radiology (O.H., H.S., A.I., N.T., N.M., Y.F., M.T., M.Y., T.D., J.N., H.N.) and Medical Physics (T.J.), Osaka University Graduate School of Medicine, 1-7 Yamadaoka, Suita, Osaka 565-0871, Japan. From the 2006 RSNA Annual Meeting. Received December 12, 2006; revision requested February 13, 2007; revision received March 10; accepted March 23; final version accepted May 22. Address correspondence to O.H. (e-mail: ohonda{at}radiol.med.osaka-u.ac.jp).

Purpose: To retrospectively evaluate the effect of contrast medium on the three-dimensional volumetric measurement of pulmonary nodules.

Materials and Methods: The study was approved by the local institutional review committee, with waiver of informed consent. Sixty pulmonary nodules in 60 patients (17 women, 43 men; age range, 29–82 years) were imaged before and after administration of contrast medium with a 64-channel multidetector computed tomographic (CT) scanner; reconstructed images with a section thickness of 0.625 mm were obtained by using a bone algorithm and a standard algorithm. Volumetric measurements of pulmonary nodules were performed by using commercially available software, and the postcontrast volume ratio was calculated by dividing the postcontrast volume by the precontrast volume. Precontrast and postcontrast volumes were then analyzed by using a Wilcoxon signed rank test.

Results: The median measured volumes of pulmonary nodules were 817 mm3 (precontrast imaging, bone algorithm), 887 mm3 (postcontrast imaging, bone algorithm), 812 mm3 (precontrast imaging, standard algorithm), and 855 mm3 (postcontrast imaging, standard algorithm). The measured volumes obtained with the bone algorithm were significantly larger than those obtained with the standard algorithm, both before and after administration of contrast medium (P < .01); with both the standard algorithm and the bone algorithm, the measured postcontrast volumes were significantly larger than the precontrast volumes (P < .01). The postcontrast volume ratio was more than 1.0 in 45 cases (75%) when the bone algorithm was used and in 53 cases (88%) when the standard algorithm was used. The mean postcontrast volume ratio was 1.054 with the bone algorithm and 1.065 with the standard algorithm.

Conclusion: The measured volume of pulmonary nodules obtained by using three-dimensional volumetric software increased after administration of contrast medium. Moreover, the measured volume of pulmonary nodules that was obtained with the bone algorithm was larger than that obtained with the standard algorithm, regardless of whether contrast medium was used.

© RSNA, 2007







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2007 by the Radiological Society of North America.