Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2462061674
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Haystead, C. M.
Right arrow Articles by Merkle, E. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haystead, C. M.
Right arrow Articles by Merkle, E. M.
(Radiology 2008;246:589-595.)
© RSNA, 2008


Technical Developments

N/2 Ghosting Artifacts: Elimination at 3.0-T MR Cholangiography with SPACE Pulse Sequence1

Clare M. Haystead, MD, Brian M. Dale, PhD, and Elmar M. Merkle, MD

1 From the Department of Radiology, Duke University Medical Center, Erwin Rd, Durham, NC 27710 (C.M.H., E.M.M.); and Siemens Medical Solutions, Cary, NC (B.M.D.). Received September 27, 2006; revision requested December 7; revision received March 1, 2007; accepted March 21; final version accepted July 16. Address correspondence to C.M.H. (e-mail: clare.haystead{at}duke.edu).

This HIPAA-compliant study had institutional review board approval, with waiver of informed consent. The purpose was to test the hypothesis that, compared with a standard magnetic resonance (MR) cholangiography sequence, MR cholangiography with a sampling perfection with application optimized contrasts using different flip angle evolutions (SPACE) sequence reduces ghosting artifacts while maintaining image quality and sufficient contrast-to-noise ratio (CNR) at 3.0 T. The study population consisted of 15 women and 14 men (mean age, 47.2 years ± 18.1 [standard deviation]) who were consecutively referred for MR cholangiography between November 2004 and November 2005. Acquisition times were lower and N/2 ghosting artifacts were eliminated with SPACE. However, the SPACE sequence yielded images that were visually grainier and had lower CNR. Overall, the readers preferred the appearance of images obtained with the SPACE sequence, most likely because of the elimination of N/2 ghosting artifacts.