|
|
||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Cardiac Imaging |
1 From the Departments of Radiology (W.P.S., J.M.M., L.M.M., T.J.D., B.H.W., J.H.C.); Medicine, Division of Cardiology (K.R.B., J.H.C.); and Biostatistics (D.W.L.), University of Washington School of Medicine, 1959 NE Pacific St, Seattle, WA 98195. Received December 21, 2007; revision requested February 19, 2008; revision received February 22; final version accepted February 27. Address correspondence to W.P.S. (e-mail: wshuman{at}u.washington.edu).
Purpose: To compare image quality and patient radiation dose in a group of patients who underwent 64-detector computed tomography (CT) coronary angiography performed with prospective electrocardiographic (ECG) gating with image quality and radiation dose in a group of patients matched for clinical features who underwent 64-detector CT coronary angiography performed with retrospective ECG gating.
Materials and Methods: Institutional review board approval was obtained for this HIPAA-compliant study, and the informed consent requirement was waived due to the retrospective study design. Two independent reviewers separately scored coronary artery segment image quality and overall image quality for 100 cardiac CT studies (50 in each group). Interobserver variability was calculated. Patient radiation dose for the actual examination z-axis length was recorded, and a normalized dose was calculated for a 12-cm z-axis length of a typical heart.
Results: The two groups matched well for clinical characteristics and CT parameters. There was good agreement for coronary artery segment image quality scores between the independent reviewers (
= 0.72). Of the 1253 coronary artery segments scored, the number of coronary artery segments that could not be evaluated in each group was similar (1.1% [seven of 614] in the prospective group vs 1.5% [10 of 647] in the retrospective group, P = .53). Image quality scores were not significantly different when matched for chest cross-sectional area (P > .05). Mean patient radiation dose was 77% lower for prospective gating (4.2 mSv) than for retrospective gating (18.1 mSv) (P < .01).
Conclusion: Use of 64-detector CT coronary angiography performed with prospective ECG gating has similar subjective image quality scores but 77% lower patient radiation dose when compared with use of retrospective ECG gating.
© RSNA, 2008
Related Article
Radiology 2008 248: 424-430.
This article has been cited by other articles:
![]() |
G. L. Raff, K. M. Chinnaiyan, D. A. Share, T. Y. Goraya, E. A. Kazerooni, M. Moscucci, R. E. Gentry, A. Abidov, and for the Advanced Cardiovascular Imaging Consortium Radiation Dose From Cardiac Computed Tomography Before and After Implementation of Radiation Dose-Reduction Techniques JAMA, June 10, 2009; 301(22): 2340 - 2348. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Achenbach, V. Dilsizian, C. M. Kramer, and W. A. Zoghbi The Year in Coronary Artery Disease J. Am. Coll. Cardiol. Img., June 1, 2009; 2(6): 774 - 786. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. P. Shuman, K. R. Branch, J. M. May, L. M. Mitsumori, J. N. Strote, B. H. Warren, T. J. Dubinsky, D. W. Lockhart, and J. H. Caldwell Whole-Chest 64-MDCT of Emergency Department Patients with Nonspecific Chest Pain: Radiation Dose and Coronary Artery Image Quality with Prospective ECG Triggering Versus Retrospective ECG Gating Am. J. Roentgenol., June 1, 2009; 192(6): 1662 - 1667. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. A. Flachskampf and D. Ropers Computed tomography to analyze mitral valve an answer in search of a question. J. Am. Coll. Cardiol. Img., May 1, 2009; 2(5): 566 - 568. [Full Text] [PDF] |
||||
![]() |
K. M. Takakuwa, E. J. Halpern, E. L. Gingold, D. C. Levin, and F. S. Shofer Radiation Dose in a "Triple Rule-Out" Coronary CT Angiography Protocol of Emergency Department Patients Using 64-MDCT: The Impact of ECG-Based Tube Current Modulation on Age, Sex, and Body Mass Index Am. J. Roentgenol., April 1, 2009; 192(4): 866 - 872. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Pflederer, L. Rudofsky, D. Ropers, S. Bachmann, M. Marwan, W. G. Daniel, and S. Achenbach Image Quality in a Low Radiation Exposure Protocol for Retrospectively ECG-Gated Coronary CT Angiography Am. J. Roentgenol., April 1, 2009; 192(4): 1045 - 1050. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Husmann, B. A. Herzog, O. Gaemperli, F. Tatsugami, N. Burkhard, I. Valenta, P. Veit-Haibach, C. A. Wyss, U. Landmesser, and P. A. Kaufmann Diagnostic accuracy of computed tomography coronary angiography and evaluation of stress-only single-photon emission computed tomography/computed tomography hybrid imaging: comparison of prospective electrocardiogram-triggering vs. retrospective gating Eur. Heart J., March 1, 2009; 30(5): 600 - 607. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. R. Mayo and J. A. Leipsic Radiation Dose in Cardiac CT Am. J. Roentgenol., March 1, 2009; 192(3): 646 - 653. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. P. Agarwal, A. Chughtai, F. R. K. Matzinger, and E. A. Kazerooni Multidetector CT of Thoracic Aortic Aneurysms RadioGraphics, March 1, 2009; 29(2): 537 - 552. [Abstract] [Full Text] [PDF] |
||||