Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2483072098
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Weustink, A. C.
Right arrow Articles by Krestin, G. P.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Weustink, A. C.
Right arrow Articles by Krestin, G. P.
(Radiology 2008;248:792-798.)
© RSNA, 2008


Cardiac Imaging

Optimal Electrocardiographic Pulsing Windows and Heart Rate: Effect on Image Quality and Radiation Exposure at Dual-Source Coronary CT Angiography1

Annick C. Weustink, MD, Nico R. Mollet, MD, PhD, Francesca Pugliese, MD, Willem B. Meijboom, MD, Koen Nieman, MD, PhD, Majanka H. Heijenbrok-Kal, PhD, Thomas G. Flohr, PhD, Lisanne A. E. Neefjes, MD, Filippo Cademartiri, MD, PhD, Pim J. de Feyter, MD, PhD, and Gabriel P. Krestin, MD, PhD

1 From the Departments of Radiology (A.C.W., N.R.M., F.P., W.B.M., K.N., M.H.H., L.A.E.N., F.C., P.J.d.F., G.P.K.), Cardiology, Thoraxcenter (A.C.W., N.R.M., F.P., W.B.M., K.N., L.A.E.N., F.C., P.J.d.F.), and Epidemiology and Biostatistics (M.H.H.), Erasmus Medical Center, PO Box 2040, Room Hs 218, 3000 CA Rotterdam, the Netherlands; and Siemens Medical Solutions, Forchheim, Germany (T.G.F.). Received December 6, 2007; revision requested January 24, 2008; revision received February 22; final version accepted March 3. Address correspondence to G.P.K. (e-mail: g.p.krestin{at}erasmusmc.nl).

Purpose: To determine the optimal width and timing of the electrocardiographic (ECG) pulsing window within the cardiac cycle in relation to heart rate (HR), image quality, and radiation exposure in patients who are suspected of having coronary artery disease.

Materials and Methods: The institutional review board approved the study, and all patients gave informed consent. Dual-source computed tomography (CT) was performed in 301 patients (mean HR, 70.1 beats per minute ± 13.3 [standard deviation]; range, 43–112 beats per minute) by using a wide ECG pulsing window (25%–70% of the R-R interval). Data sets were reconstructed in 5% steps from 20%–75% of R-R interval. Image quality was assessed by two observers on a per-segment level and was classified as good or impaired. High-quality data sets were those in which each segment was of good quality. The width and timing of the image reconstruction window was calculated. On the basis of these findings, an optimal HR-dependent ECG pulsing protocol was designed, and the potential dose-saving effect on effective dose (in millisieverts) was calculated.

Results: At low HR (≤65 beats per minute), high-quality data sets were obtained during end diastole (ED); at high HR (≥80 beats per minute), they were obtained during end systole (ES); and at intermediate HR (66–79 beats per minute), they were obtained during both ES and ED. Optimal ECG pulsing windows for low, intermediate, and high HR were at 60%–76%, 30%–77%, and 31%–47% of the R-R interval, respectively, and with these levels, the effective dose was decreased at low HR from 18.7 to 6.8 mSv, at intermediate HR from 14.7 to 13.4 mSv, and at high HR from 11.3 to 4.2 mSv.

Conclusion: With optimal ECG pulsing, radiation exposure to patients, particularly those with low or high HR, can be reduced with preservation of image quality.

© RSNA, 2008