Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2483072067
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wilczynski, N. L.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Wilczynski, N. L.
Related Collections
Right arrowRelated Article
(Radiology 2008;248:817-823.)
© RSNA, 2008


Evidence-based Practice

Quality of Reporting of Diagnostic Accuracy Studies: No Change Since STARD Statement Publication—Before-and-after Study1

Nancy L. Wilczynski, MSc, PhD

1 From the Health Information Research Unit, McMaster University, 1200 Main St West, HSC-3H7, Hamilton, ON, Canada L8N 3Z5. Received November 28, 2007; revision requested February 1, 2008; revision received February 8; accepted April 1; final version accepted April 10. Address correspondence to the author (e-mail: wilczyn{at}mcmaster.ca).

Purpose: To determine the quality of reporting of diagnostic accuracy studies before and after the Standards for Reporting of Diagnostic Accuracy (STARD) statement publication and to determine whether there is a difference in the quality of reporting by comparing STARD (endorsing) and non-STARD (nonendorsing) journals.

Materials and Methods: Diagnostic accuracy studies were identified by hand searching six STARD and six non-STARD journals for 2001, 2002, 2004, and 2005. Diagnostic accuracy studies (n = 240) were assessed by using a checklist of 13 of 25 STARD items. The change in the mean total score on the modified STARD checklist was evaluated with analysis of covariance. The change in proportion of times that each individual STARD item was reported before and after STARD statement publication was evaluated ({chi}2 tests for linear trend).

Results: With mean total score as dependent factor, analysis of covariance showed that the interaction between the two independent factors (STARD or non-STARD journal and year of publication) was not significant (F = 0.664, df = 3, partial {eta}2 = 0.009, P = .58). Additionally, the frequency with which individual items on the STARD checklist were reported before and after STARD statement publication has remained relatively constant, with little difference between STARD and non-STARD journals.

Conclusion: After publication of the STARD statement in 2003, the quality of reporting of diagnostic accuracy studies remained similar to pre–STARD statement publication levels, and there was no meaningful difference (ie, one additional item on the checklist of 13 of 25 STARD items being reported) in the quality of reporting between those journals that published the STARD statement and those that did not.

© RSNA, 2008


Related Article

STARD Statement: Still Room for Improvement in the Reporting of Diagnostic Accuracy Studies
Patrick M. M. Bossuyt
Radiology 2008 248: 713-714. [Full Text] [PDF]



This article has been cited by other articles:


Home page
RadiologyHome page
P. M. M. Bossuyt
STARD Statement: Still Room for Improvement in the Reporting of Diagnostic Accuracy Studies
Radiology, September 1, 2008; 248(3): 713 - 714.
[Full Text] [PDF]