Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published online before print September 9, 2008, 10.1148/radiol.2483080193

(Radiology 2008;249:682.)

A more recent version of this article appeared on November 1, 2008
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow All Versions of this Article:
2483080193v1
249/2/682    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Stolzmann, P.
Right arrow Articles by Schertler, T.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stolzmann, P.
Right arrow Articles by Schertler, T.
Related Collections
Right arrowRelated Article
© RSNA, 2008

Vascular and Interventional Radiology

Endoleaks after Endovascular Abdominal Aortic Aneurysm Repair: Detection with Dual-Energy Dual-Source CT1

Paul Stolzmann, MD, Thomas Frauenfelder, MD, Thomas Pfammatter, MD, Nicole Peter, MD, Hans Scheffel, MD, Mario Lachat, MD, Bernhard Schmidt, PhD, Borut Marincek, MD, Hatem Alkadhi, MD, and Thomas Schertler, MD

1 From the Institute of Diagnostic Radiology (P.S., T.F., T.P., N.P., H.S., B.M., H.A., T.S.) and Clinic for Cardiovascular Surgery (M.L.), University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland; and Siemens Medical Solutions, Forchheim, Germany (B.S.). Received January 30, 2008; revision requested March 28; revision received April 5; accepted April 8; final version accepted April 10. Supported by the National Center of Competence in Research, Computer Aided and Image Guided Medical Interventions of the Swiss National Science Foundation. Address correspondence to H.A. (e-mail: hatem.alkadhi{at}usz.ch).

Purpose: To assess the diagnostic performance of dual-energy dual-source computed tomography (CT) in the detection of endoleaks after endovascular abdominal aortic aneurysm (AAA) repair.

Materials and Methods: This study was local ethics board approved, and written informed consent was obtained from all patients. One hundred eighteen patients (21 women, 97 men; mean age, 74 years ± 8 [standard deviation]) underwent follow-up dual-energy dual-source CT during the nonenhanced, arterial, and delayed phases after AAA repair. Delayed phase CT images were acquired in the dual-energy mode for reconstruction of virtual nonenhanced images. Two blinded and independent readers evaluated the data for the presence or absence of endoleaks during three reading sessions: Standard nonenhanced, arterial phase, and delayed phase images were read during session A; virtual nonenhanced, arterial phase, and delayed phase images, during session B; and virtual nonenhanced and delayed phase images, during session C. Sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) were calculated, with the session A image data set as the reference standard. Radiation dose parameters were estimated.

Results: Reading session A revealed that 52 (44%) of 118 patients had endoleaks. Overall sensitivity, specificity, NPV, and PPV for CT endoleak detection during sessions B and C were identical: 100%, 97%, 100%, and 96%, respectively. The accuracy of the session B and session C readings was not significantly different from that of the session A reading (P = .50). The effective radiation dose in the image acquisition protocol involving one dual-energy scan was significantly (P < .001) lower than the effective doses in the protocols involving standard triple-phase scanning (mean difference, 61%) and standard nonenhanced and delayed phase scanning (mean difference, 41%).

Conclusion: Compared with standard protocols, one dual-energy dual-source CT scan performed during the delayed phase with reconstruction of virtual nonenhanced images enables detection of endoleaks after endovascular AAA repair with high accuracy and a considerably lower radiation dose.

© RSNA, 2008


Related Article

Abdominal Aorta: Evaluation with Dual-Source Dual-Energy Multidetector CT after Endovascular Repair of Aneurysms—Initial Observations
Hersh Chandarana, Myrna C. B. Godoy, Ioannis Vlahos, Anno Graser, James Babb, Christianne Leidecker, and Michael Macari
Radiology 2008 249: 692-700. [Abstract] [Full Text] [PDF]






HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2008 by the Radiological Society of North America.