Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print October 10, 2008, 10.1148/radiol.2492080146
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2492080146v1
249/3/792    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Westenberg, J. J. M.
Right arrow Articles by van der Geest, R. J.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Westenberg, J. J. M.
Right arrow Articles by van der Geest, R. J.
(Radiology 2008;249:792-800.)
© RSNA, 2008


Cardiac Imaging

Mitral Valve and Tricuspid Valve Blood Flow: Accurate Quantification with 3D Velocity-encoded MR Imaging with Retrospective Valve Tracking1

Jos J. M. Westenberg, PhD, Stijntje D. Roes, MD, Nina Ajmone Marsan, MD, Nico M. J. Binnendijk, Joost Doornbos, PhD, Jeroen J. Bax, PhD, MD, Johan H. C. Reiber, PhD, Albert de Roos, PhD, MD, and Robert J. van der Geest, MSc

1 From the Departments of Radiology (J.J.M.W., S.D.R., N.M.J.B., J.D., J.H.C.R., A.d.R., R.J.v.d.G.) and Cardiology (N.A.M., J.J.B.), Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, the Netherlands. From the 2007 RSNA Annual Meeting. Received January 24, 2008; revision requested March 25; revision received April 21; accepted May 19; final version accepted May 21. Address correspondence to J.J.M.W. (e-mail: j.j.m.westenberg{at}lumc.nl).

Purpose: To validate flow assessment performed with three-dimensional (3D) three-directional velocity-encoded (VE) magnetic resonance (MR) imaging with retrospective valve tracking and to compare this modality with conventional two-dimensional (2D) one-directional VE MR imaging in healthy subjects and patients with regurgitation.

Materials and Methods: Patients and volunteers gave informed consent, and local medical ethics committee approval was obtained. Patient data were selected retrospectively and randomly from a database of MR studies obtained between July 2006 and July 2007. The 3D three-directional VE MR images were first validated in vitro and compared with 2D one-directional VE MR images. Mitral valve (MV) and tricuspid valve (TV) flow were assessed in 10 volunteers without valve insufficiency and 20 patients with valve insufficiency, with aortic systolic stroke volume (ASSV) as the reference standard.

Results: Phantom validation showed less than 5% error for both techniques. In volunteers, 3D three-directional VE MR images showed no bias for MV or TV flow when compared with ASSV, whereas 2D one-directional VE MR images showed significant bias for MV flow (15% overestimation, P < .01). TV flow showed 25% overestimation; however, this was insignificant because of the high standard deviation. Correlation with ASSV was strong for 3D three-directional VE MR imaging (r = 0.96, P < .01 for MV flow; r = 0.88, P < .01 for TV flow) and between MV and TV flow (r = 0.91, P < .01); however, correlation was weaker for 2D one-directional VE MR imaging (r = 0.80, P < .01 for MV flow; r = 0.22, P = .55 for TV flow) and between MV flow and TV flow (r = 0.34, P = .34). In patients (mean regurgitation fractions of 13% and 10% for MV flow and TV flow, respectively), correlation between MV flow and TV flow for 3D three-directional VE MR imaging was strong (r = 0.97, P < .01).

Conclusion: Use of 3D three-directional VE MR imaging enables accurate MV and TV flow quantification, even in patients with valve regurgitation.