Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published online before print September 16, 2008, 10.1148/radiol.2492072009

(Radiology 2008;249:534.)

A more recent version of this article appeared on November 1, 2008
This Article
Right arrow Full Text
Right arrow Appendix E1
Right arrow All Versions of this Article:
2492072009v1
249/2/534    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Lockhart, M. E.
Right arrow Articles by Weber, A. M.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lockhart, M. E.
Right arrow Articles by Weber, A. M.
© RSNA, 2008

Genitourinary Imaging

Reproducibility of Dynamic MR Imaging Pelvic Measurements: A Multi-institutional Study1

Mark E. Lockhart, MD, MPH, Julia R. Fielding, MD, Holly E. Richter, MD, PhD, Linda Brubaker, MD, Caryl G. Salomon, MD, Wen Ye, MD, Christiane M. Hakim, MD, Clifford Y. Wai, MD, Alan H. Stolpen, MD, and Anne M. Weber, MD

1 From the Departments of Radiology (M.E.L.) and Obstetrics and Gynecology (H.E.R.), University of Alabama at Birmingham, 625 19th St South, JTN Room 363, Birmingham, AL 35249; Department of Radiology, University of North Carolina, Chapel Hill, NC (J.R.F.); Departments of Obstetrics & Gynecology and Urology (L.B.) and Radiology (C.G.S.), Loyola University, Chicago, Ill; Department of Biostatistics, University of Michigan, Ann Arbor, Mich (W.Y.); Department of Radiology, University of Pittsburgh, Pittsburgh, Pa (C.M.H.); Department of Obstetrics and Gynecology, University of Texas–Southwestern, Dallas, Tex (C.Y.W.); Department of Radiology, University of Iowa, Iowa City, Iowa (A.H.S.); Edward Hines, Jr., VA Hospital, Hines, Ill (C.G.S.); and National Institute of Child Health and Human Development, Bethesda, Md (A.M.W.). Received November 16, 2007; revision requested January 15, 2008; revision received May 19; accepted May 30; final version accepted June 16. Supported in part by National Institute of Child Health and Human Development grants 2U10 HD41249, 2U10 HD41250, 2U10 HD41261, 2U10 HD41267, 1U10 HD41248, 1U10 HD41263, 1U10 HD41268, and 1U10 HD41269. Address correspondence to M.E.L. (e-mail: mlockhart{at}uabmc.edu).

Purpose: To assess the reproducibility of bone and soft-tissue pelvimetry measurements obtained from dynamic magnetic resonance (MR) imaging studies in primiparous women across multiple centers.

Materials and Methods: All subjects prospectively gave consent for participation in this institutional review board–approved, HIPAA-compliant study. At six clinical sites, standardized dynamic pelvic 1.5-T multiplanar T2-weighted MR imaging was performed in three groups of primiparous women at 6–12 months after birth: Group 1, vaginal delivery with anal sphincter tear (n = 93); group 2, vaginal delivery without anal sphincter tear (n = 79); and group 3, cesarean delivery without labor (n = 26). After standardized central training, blinded readers at separate clinical sites and a blinded expert central reader measured nine bone and 10 soft-tissue pelvimetry parameters. Subsequently, three readers underwent additional standardized training, and reread 20 MR imaging studies. Measurement variability was assessed by using intraclass correlation for agreement between the clinical site and central readers. Acceptable agreement was defined as an intraclass correlation coefficient (ICC) of at least 0.7.

Results: There was acceptable agreement (ICC range, 0.71–0.93) for eight of 19 MR imaging parameters at initial readings of 198 subjects. The remaining parameters had an ICC range of 0.13–0.66. Additional training reduced measurement variability: Twelve of 19 parameters had acceptable agreement (ICC range, 0.70–0.92). Correlations were greater for bone (ICC, ≥0.70 in five [initial readings] and eight of nine [rereadings] variables) than for soft-tissue measurements (ICC, ≥0.70 in three [initial readings] of 10 and four [rereadings] of 10 readings, respectively).

Conclusion: Despite standardized central training, there is high variability of pelvic MR imaging measurements among readers, particularly for soft-tissue structures. Although slightly improved with additional training, measurement variability adversely affects the utility of many MR imaging measurements for multicenter pelvic floor disorder research.

Supplemental material: http://radiology.rsnajnls.org/cgi/content/full/2492072009/DC1