Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2501071809
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Quicktime Movie
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Murayama, K.
Right arrow Articles by Murphy, K. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Murayama, K.
Right arrow Articles by Murphy, K. J.
(Radiology 2009;250:202-211.)
© RSNA, 2009


Neuroradiology

Whole-Brain Perfusion CT Performed with a Prototype 256–Detector Row CT System: Initial Experience1

Kazuhiro Murayama, MD, Kazuhiro Katada, MD, Masato Nakane, MD, Hiroshi Toyama, MD, Hirofumi Anno, MD, Motoharu Hayakawa, MD, Diego San Millan Ruiz, MD, and Kieran J. Murphy, MD

1 From the Department of Radiology (K.M., K.K., H.T.), Faculty of Radiological Technology, School of Health Sciences (H.A.), and Department of Neurosurgery (M.H.), Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi 470-1192, Japan; Department of Radiology, Nagoya Central Hospital, Nagoya, Japan (M.N.); and Division of Interventional Neuroradiology, Department of Radiology, Johns Hopkins Medical Institutions, Baltimore, Md (D.S.M.R., K.J.M.). From the 2006 RSNA Annual Meeting. Received October 16, 2007; revision requested January 4, 2008; revision received April 5; accepted June 27; final version accepted July 30. Address correspondence to K.M. (e-mail: kmura{at}fujita-hu.ac.jp).

Purpose: To preliminarily evaluate the feasibility and potential diagnostic utility of whole-brain perfusion computed tomography (CT) performed with a prototype 256–detector row CT system over an extended range covering the entire brain to assess ischemic cerebrovascular disease.

Materials and Methods: Institutional review board approval and informed consent were obtained. Eleven cases in 10 subjects (six men, four women; mean age, 64.3 years) with intra- or extracranial stenosis were retrospectively evaluated with whole-brain perfusion CT. Three readers independently evaluated perfusion CT data. The diagnostic performance of perfusion CT was visually evaluated with a three-point scale used to assess three factors. Differences between four axial perfusion CT images obtained at the basal ganglia level (hereafter, four-section images) and whole-brain perfusion CT images were assessed with the paired t test. In four subjects, the interval between perfusion CT and single photon emission computed tomography (SPECT) was 1–17 days (mean, 10.3 days). Correlation between perfusion CT findings and SPECT findings was assessed with the Spearman correlation coefficient.

Results: Three-dimensional perfusion CT images and axial, coronal, and sagittal whole-brain perfusion CT images were displayed, and the extent of ischemia was assessed. Mean visual evaluation scores were significantly higher for whole-brain images than for four-section images (4.27 ± 0.76 [standard deviation] vs 2.55 ± 0.87). The cerebral blood flow ratios of the ischemic lesions relative to normal regions scanned with perfusion CT (x) and SPECT (y) showed a significant positive correlation (R2 = 0.76, y = 0.44x + 0.37, P < .001).

Conclusion: Perfusion CT performed with a 256–detector row CT system can be used to assess the entire brain with administration of one contrast medium bolus. Thus, ischemic regions can be identified with one examination, which has the potential to improve diagnostic utility.

Supplemental material: http://radiology.rsnajnls.org/cgi/content/full/250/1/202/DC1

© RSNA, 2009