Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


DOI: 10.1148/radiol.2493080353
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Podcast
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Harieaswar, S.
Right arrow Articles by Morgan, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Harieaswar, S.
Right arrow Articles by Morgan, B.
(Radiology 2009;250:246-253.)
© RSNA, 2009


Technical Developments

Routine Use of Positive Oral Contrast Material Is Not Required for Oncology Patients Undergoing Follow-up Multidetector CT1

Sreemathi Harieaswar, MRCP, FRCR, Arumugam Rajesh, FRCR, Yvette Griffin, MRCP, FRCR, Raman Tyagi, MD, FRCR, and Bruno Morgan, PhD, MRCP, FRCR

1 From the Department of Radiology, Leicester Royal Infirmary, Leicester LE1 5WW, England. Received February 22, 2008; revision requested April 30; revision received June 6; accepted June 27; final version accepted July 15. Address correspondence to B.M. (e-mail: bm11{at}le.ac.uk).

The purpose of this retrospective medical audit was to evaluate the effect of discontinuing routine administration of oral contrast material to oncology patients undergoing follow-up multidetector computed tomography (CT) on reader evaluation of study adequacy. Analysis of 100 patients' experience of CT shows that positive oral contrast material was their least pleasant experience (P < .0001). Abandoning the routine use of positive oral contrast material for follow-up scans in general oncology patients undergoing multidetector CT, with section reconstruction thickness of 2.5 mm, was audited for 447 patents and included 5–13-month follow-up. The patient satisfaction study and clinical audit were performed according to local institutional audit guidelines. Since this was a clinical audit project, ethical approval was not required under UK National Health Service research governance arrangements. No patient needed to be recalled, no related diagnostic error has been reported, and follow-up CT, available in 285 of 447 cases (64%), revealed no error on the audited scan. We conclude that the routine use of positive oral contrast material is unnecessary for follow-up multidetector CT for general oncology indications.

© RSNA, 2009