Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print September 19, 2002, 10.1148/radiol.2252010845
This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2252010845v1
225/2/519    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Huo, Z.
Right arrow Articles by Cummings, S. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Huo, Z.
Right arrow Articles by Cummings, S. A.
(Radiology 2002;225:519-526.)
© RSNA, 2002


Breast Imaging

Computerized Analysis of Digitized Mammograms of BRCA1 and BRCA2 Gene Mutation Carriers1

Zhimin Huo, PhD, Maryellen L. Giger, PhD, Olufunmilayo I. Olopade, MD, Dulcy E. Wolverton, MD, Barbara L. Weber, MD, Charles E. Metz, PhD, Weiming Zhong, MS and Shelly A. Cummings, MS

1 From the Departments of Radiology (Z.H., M.L.G., D.E.W., C.E.M., W.Z.) and Hematology and Oncology (O.I.O., S.A.C.), University of Chicago, 5841 S Maryland Ave, Chicago, IL 60637; and Department of Hematology and Oncology, University of Pennsylvania Medical Center, Philadelphia (B.L.W.). From the 1998 and 2000 RSNA scientific assemblies. Received April 27, 2001; revision requested June 8; final revision received April 18, 2002; accepted May 16. Supported in part by grants from the NIH (P20 CA66132 and R21 CA79711), from the U.S. Army Medical Research and Materiel Command (DAMD 17-96-1-6058 and 17-99-1209), and from the Elizabeth Boughton Charitable Fund and the Falk Medical Research Fund. Address correspondence to M.L.G. (e-mail: m-giger@uchicago.edu).


    ABSTRACT
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 APPENDIX
 REFERENCES
 
PURPOSE: To evaluate, by using computer image analysis, the mammographic density patterns of women with germ-line mutations in BRCA1 and BRCA2 genes in comparison with those of women at low risk of developing breast cancer.

MATERIALS AND METHODS: Mammograms from 30 carriers of BRCA1 and BRCA2 mutations and from 142 low-risk women were collected retrospectively and digitized. In addition, 60 of the 142 low-risk women were randomly selected and age matched at 5-year intervals with the 30 mutation carriers. Mammographic features were extracted from the central regions of the breast images to characterize the mammographic density and heterogeneity of dense portions of the breast. These features were then merged into a single value related to the risk of breast cancer by using linear discriminant analysis. The applicability of these computer-extracted features and the output from linear discriminant analysis to differentiate between the carriers of BRCA1 and BRCA2 mutations and the low-risk women in the entire database and in an age-matched group were evaluated by using receiver operating characteristic analysis.

RESULTS: Quantitative analysis of mammograms demonstrated that carriers of BRCA1 and BRCA2 mutations tended to have dense breast tissue, and their mammographic patterns tended to be low in contrast, with a coarse texture. Linear discriminant analysis resulted in values of the areas under the receiver operating characteristic curve of 0.91 and 0.92 in distinguishing between the BRCA1 and BRCA2 mutation carriers and the low-risk women in the entire database and the age-matched group, respectively.

CONCLUSION: The computerized analysis of mammograms suggests that mammographic patterns in carriers of BRCA1 and BRCA2 mutations differ from those of women at low risk for breast cancer. Our computer-extracted features may be useful as radiographic markers for identifying women at high risk for breast cancer.

© RSNA, 2002

Index terms: Breast, diseases, 00.32 • Breast neoplasms, radiography, 00.11 • Computers, diagnostic aid • Genes and genetics • Receiver operating characteristic (ROC) curve


    INTRODUCTION
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 APPENDIX
 REFERENCES
 
Approximately 5%–10% of all breast cancers are due to hereditary susceptibility (1,2). Women who inherit a mutated form of breast cancer susceptibility genes such as BRCA1 and BRCA2 possess a high risk of developing breast cancer. These women have an estimated breast cancer risk as high as 20% by age 40 years, 50% by age 50 years, and 87% by age 70 years (3). These rates are eight times higher than the lifetime risk for women in the general population and 50–100 times higher than the lifetime risk in younger age groups. Identification and close surveillance of women with hereditary susceptibility to breast cancer may provide an opportunity for early detection or prevention of the disease among these women.

Various studies (47) have shown that increased mammographic density is associated with an increased risk of breast cancer. At present, the explanation for this increased risk is unclear. One possibility is that increased density reflects a larger amount of tissue at risk for developing breast cancer. Since most breast cancers develop from the epithelial cells that line the ducts of the breast, having more of this tissue, as reflected by increased mammographic density, may increase one’s chances of developing breast cancer. The histopathologic changes in BRCA1- and BRCA2-associated cancers are often characteristic of the mutant gene and different from sporadic cancers (8). For example, BRCA1-associated breast cancers occur at an earlier average age (44 years) than do sporadic breast cancers (9). In addition, as compared with noncarriers, women with BRCA1-associated breast cancers are characterized by higher-than-expected frequencies of medullary or atypical medullary carcinoma, poorly differentiated (high-grade) tumors, aneuploidy, high S-phase fraction, hormone receptor negativity, and p53 mutation (10,11). BRCA2 tumors are more differentiated, with more tubular and lobular features and a higher rate of hormone receptor positivity. However, it is not known whether differences exist in the nonmalignant breast parenchymal tissue of BRCA1 and BRCA2 mutation carriers when compared with that of noncarriers.

Mammographic parenchymal patterns have been characterized in terms of Wolfe patterns (Dy, P1, P2, and N1) (12) or percentage density (ie, percentage area that appears mammographically dense) with either visual or computerized assessment (13). These assessments were then related to breast cancer risk. Byng et al (14) found that women with dense breast tissue have a higher risk (relative risk >= 2.0) of developing breast cancer on the basis of computerized assessments. Individual risk in their study was estimated from the observed breast cancer incidence in the studied population (14). Tahoces et al (15) showed that the mammographic patterns of women with the Dy pattern, which is associated with the highest breast cancer risk, as defined by Wolfe, tend to be coarser than those in women with the other three patterns (ie, P1, P2, and N1). More recently, Huo et al (16) identified computer-extracted features with which to characterize breast density and parenchymal texture patterns from digitized mammograms.

Computerized analysis of digital mammograms is expected to provide more objective and reproducible characterization of mammographic parenchymal patterns than that based on visual assessment. Consequently, the variability introduced by the subjective nature of human observers may be reduced (13). The purpose of our study was to evaluate mammographic patterns, including mammographic density, in women with germ-line mutations in BRCA1 and BRCA2 genes versus that in women at low risk for developing breast cancer, by using computer image analysis.


    MATERIALS AND METHODS
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 APPENDIX
 REFERENCES
 
Database
Patients with known BRCA1 and BRCA2 mutations were recruited from cancer risk evaluation clinics at the University of Chicago and the University of Pennsylvania, where genetic counseling is available for women at high risk for breast cancer. All mutation carriers had been tested at a laboratory approved by the Clinical Laboratory Improvement Amendments under institutional review board–approved research protocols at the two institutions. Mammograms obtained previously were retrieved and digitized for all women who were willing to contribute to the database. Institutional review board–approved procedures (including patient consent) were used at both institutions to retrospectively collect mammograms and review patient information (W.Z., S.A.C.). To ensure the quality of the mammograms used in the study, we used only mammograms acquired after 1990, since that is the year in which modern mammographic techniques were first used in most hospitals. Further, to eliminate the potential effect of cancer treatment, including radiation therapy, chemotherapy, and/or tamoxifen use on mammographic parenchymal patterns, only mammograms obtained prior to cancer diagnosis were used. Thus, to be eligible for the study, mutation carriers must have had mammograms obtained after 1990 and before cancer was diagnosed. In addition, for women known to have breast cancer, prior mammograms were reviewed by an experienced mammographer (D.E.W.) and were included only if they were free of any detectable abnormalities. A total of 30 BRCA1 and BRCA2 mutation carriers (25 with BRCA1 and five with BRCA2) had mammograms that could be used for the evaluation. Among the 30 BRCA1 and BRCA2 mutation carriers who met the eligibility criteria, 10 had no cancer; three had received a diagnosis of ovarian cancer; 16 had received a diagnosis of breast cancer; and one had received a diagnosis of both breast and ovarian cancer.

In addition, mammograms were obtained consecutively from the screening mammography program of the Department of Radiology (May to December 1996) at the University of Chicago. Information on patient reproductive history, family history of breast cancer, and history of previous breast biopsy was used to calculate the lifetime risk of breast cancer by using the Gail model (17). The Gail model is one of the most common models used to assess individual breast cancer risk and was used in a recently concluded breast cancer prevention trial (18). To be considered at low risk in the study, patients could not have a family history of breast cancer, and the lifetime risk of developing breast cancer, as estimated with the Gail model, had to be less than 10%. Of the patients who supplied the necessary information, 142 were deemed to be at low risk on the basis of the previously mentioned criteria. Tests for BRCA1 and BRCA2 mutation were not offered to these low-risk patients. It is estimated that about three in 1,000 women in the United States today have inherited susceptibility to breast cancer (19). The likely prior probability that the women in the low-risk group in the current study would harbor BRCA1 and BRCA2 mutations was low, since they had no family history of breast cancer that warranted genetic testing and were regarded as low risk without having to undergo genetic testing.

The ages of the 30 BRCA1 and BRCA2 mutation carriers were 33–55 years, with a mean age of 42.7 years and a median age of 41.0 years. The ages of the women in the low-risk group were 35–54 years, with a mean age of 44.7 years and a median age of 45.0 years. To rule out possible bias due to the difference in age distributions of the mutation carriers and the low-risk individuals, 60 low-risk individuals were randomly selected and age matched at 5-year intervals with the 30 BRCA1 and BRCA2 mutation carriers. Our entire database included the 142 low-risk women and the 30 BRCA1 and BRCA2 mutation carriers. The age-matched group included 30 BRCA1 and BRCA2 mutation carriers and 60 of the 142 low-risk women who were age-matched with the 30 mutation carriers. Statistical analysis was performed on both the entire database and the age-matched database to evaluate the applicability of computer-extracted features in differentiating between mammographic patterns in the mutation carriers and low-risk women.

Computer-extracted Features and Classification
Mammograms obtained in all cases were digitized by using a laser scanner (model LD 4500; Konica Medical, Wayne, NJ) at 0.1-mm pixel size and 10-bit gray level. After the mammograms were in digital format, regions of interest (ROIs) of 256 x 256 pixels were manually selected from the central breast region immediately behind the nipple. Figure 1 shows an ROI selected from a breast image. The small ROI size (256 x 256 pixels) was chosen to include small breasts.



View larger version (67K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 1. Digitized mammogram (craniocaudal view) shows a selected ROI.

 
An individual’s mammographic parenchymal patterns were characterized by using computer features calculated from the ROIs on digitized mammograms. ROIs were selected (W.Z.) from the central breast region behind the nipple because this region usually includes the most dense parts of the breast. A total of 14 features were investigated to quantitatively characterize an individual’s mammographic density and heterogeneous or inhomogeneous texture patterns within the dense portions of the breast (16). These included features used to quantify percentage density with use of the gray-level histogram. Texture properties of the mammographic patterns in the ROIs were characterized by using features obtained with two-dimensional Fourier transform and features (ie, contrast and coarseness) obtained from analysis of the amount of local gray-level variation and the difference among all gray levels presented in the ROI. Detailed descriptions of these features are discussed elsewhere (16).

Four features were selected from stepwise feature selection by using linear discriminant analysis (LDA) on the basis of the analysis of an initial number of cases (15 mutation carriers) from a previous study (16). Details about the four selected features (ie, skewness, balance, contrast, and coarseness) are described in the Appendix. Skewness and balance of a gray-level histogram are used to quantify percentage density, while contrast and coarseness are used to characterize the textural properties of the mammographic patterns. These four selected computer-extracted features were used to evaluate the mammographic characteristics of an extended group (including the previous 15 mutation carriers) of BRCA1 and BRCA2 mutation carriers, in comparison with those of women at low risk in both the entire database and the age-matched database. In addition, we applied LDA to merge the four selected features into a single output value that was related to the risk of breast cancer. LDA is a well-established statistical technique for the classification of two groups (21). The objective of LDA is to generate a discriminant function that is a linear combination of feature variables and outputs a discriminant score for each case. The coefficients in the function are determined such that the separation between the distributions of the discriminant scores of the two groups is maximized.

Although studies (47) have shown that increased mammographic density is associated with an increased risk for breast cancer, to our knowledge, few studies have been performed to investigate the mammographic density patterns of women with BRCA1 and BRCA2 mutations in particular (22,23). Mammographic density patterns in these prior studies were characterized on the basis of human visual assessment. In the current study, we also had an experienced radiologist (D.E.W.) rate the mammographic patterns of the cases in our database in terms of percentage density by using a 100-point scale. The computer-calculated skewness feature, as described in the Appendix, was used to estimate percentage density on the basis of gray-level histogram analysis of an ROI.

Evaluation and Statistical Analysis
The usefulness of individual computer-extracted features in differentiation between the BRCA1 and BRCA2 mutation carriers and the women at low risk was evaluated by using receiver operating characteristic (ROC) analysis (24,25). The classification performance of the linear discriminant function in combining the four features to differentiate between the mutation carriers and the low-risk cases was also evaluated by using ROC analysis (24,25).

In ROC analysis, to evaluate the applicability of a decision variable in discriminating between two groups (eg, positive and negative), a set of sensitivity and specificity pairs is calculated by varying the critical value with which the value of the decision variable (eg, an individual computer-extracted feature or the LDA output) from each case is compared. This set of sensitivity and specificity pairs can be plotted as a set of points in a unit square in terms of true-positive fraction (equivalent to sensitivity) versus false-positive fraction (equivalent to 1 - specificity). A smooth ROC curve is then fit to the set of points in the unit square with maximum-likelihood estimation by using the LABROC4 algorithm developed by Metz et al (26). The area under the fitted ROC curve (Az) is used as an index to evaluate the inherent discriminant capacity of a studied variable in differentiating between "positive" and "negative" cases. Note that an Az value can range from 0.5 to 1.0. A higher ROC curve (ie, a larger Az value) indicates a decision variable with greater discrimination performance than does a lower ROC curve (ie, a smaller Az value). With the conventional binormal curve-fitting model, a decision variable that produces an Az value of 0.5 has the same median for true-positive and true-negative cases, whereas a decision variable with an Az value of 1.0 has distributions of true-positive and true-negative cases that are completely separated.

Statistical Z tests (27) were performed to evaluate the significance of the difference between the estimated Az value of a studied decision variable (eg, an individual computer-extracted feature or the LDA output) and an Az value of 0.5. In addition, statistical tests using the CLABROC algorithm (28) for correlated data were performed to evaluate the significance of the differences between the estimated Az values of any two decision variables (eg, computer-extracted features and LDA output) in their usefulness in differentiating between the low-risk and gene mutation cases in our databases.

In the current study, we first performed ROC analysis to evaluate the usefulness of the computer-extracted features and the linear discriminant function in differentiating between the 30 BRCA1 and BRCA2 mutation carriers and the 142 low-risk cases in the entire database. Further, to remove any bias due to patient age, we performed ROC analysis on the 30 BRCA1 and BRCA2 mutation carriers and the 60 age-matched low-risk cases.


    RESULTS
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 APPENDIX
 REFERENCES
 
The usefulness of the individual features, as well as of LDA, in differentiating between the mutation carriers and the low-risk women was indicated in terms of Az values. Listed in the Table are the Az values of these features and their estimated standard errors from ROC analysis for the BRCA1 and BRCA2 mutation carriers and the low-risk cases in the entire group and in the age-matched group. Also listed are the P values calculated with statistical Z tests to evaluate the significance of the differences between the estimated individual Az values and an Az value of 0.5.


View this table:
[in this window]
[in a new window]

 
Performance of Individual Features and the Linear Discriminant Function in Distinguishing between BRCA1 or BRCA2 Mutation Carriers and the Low-Risk Cases in the Entire Group (172 Cases) and the Age-matched Group (90 Cases)

 
Figure 2 shows the distribution of the mutation carriers and the low-risk cases in the entire database in terms of skewness versus coarseness and coarseness versus contrast. As described in the Appendix, a dense ROI should yield a negative value of skewness, whereas a fatty ROI should yield a positive value of skewness. As characterized by the computer-extracted features (Fig 2), the mutation carriers tended to have more dense breast tissue than did the low-risk women, as indicated by the lower (negative) values of skewness, and their mammographic patterns tended to be coarser in texture and lower in contrast than those in the low-risk cases. Figure 3 shows the mammographic characteristics of the 30 mutation carriers and the 60 randomly selected low-risk cases in the age-matched group in terms of the selected features. Similar mammographic characteristics were observed in the mutation carriers and the low-risk women in the age-matched group; that is, the BRCA1 and BRCA2-mutation carriers tended to have dense breast tissue, and their mammographic patterns tended to be coarser, with lower contrast than those in age-matched low-risk women.



View larger version (34K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 2a. Scatterplots show distributions of the low-risk cases ({circ}) and the BRCA1 and BRCA2 mutation carriers ({blacktriangleup}) in the entire group (172 cases) in terms of (a) skewness versus coarseness and (b) coarseness versus contrast. The two-dimensional projection line from LDA corresponds to the line that yields the best (or maximum) separation between the BRCA mutation carriers and the low-risk cases in the corresponding two-dimensional feature space. As indicated by the diagonal line, the mutation carriers tended to have more dense breast tissue, with coarser and lower contrast texture patterns on their mammograms, than did the low-risk women.

 


View larger version (34K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 2b. Scatterplots show distributions of the low-risk cases ({circ}) and the BRCA1 and BRCA2 mutation carriers ({blacktriangleup}) in the entire group (172 cases) in terms of (a) skewness versus coarseness and (b) coarseness versus contrast. The two-dimensional projection line from LDA corresponds to the line that yields the best (or maximum) separation between the BRCA mutation carriers and the low-risk cases in the corresponding two-dimensional feature space. As indicated by the diagonal line, the mutation carriers tended to have more dense breast tissue, with coarser and lower contrast texture patterns on their mammograms, than did the low-risk women.

 


View larger version (27K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 3a. Scatterplots show distributions of the 60 low-risk cases ({circ}) and the 30 BRCA1 and BRCA2 mutation carriers ({blacktriangleup}) in the age-matched group in terms of (a) skewness versus coarseness and (b) coarseness versus contrast. As indicated by the separation line (Fig 2), the mutation carriers tended to have more dense breast tissue, with coarser and lower contrast texture patterns on their mammograms, than did the low-risk women in the age-matched group.

 


View larger version (28K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 3b. Scatterplots show distributions of the 60 low-risk cases ({circ}) and the 30 BRCA1 and BRCA2 mutation carriers ({blacktriangleup}) in the age-matched group in terms of (a) skewness versus coarseness and (b) coarseness versus contrast. As indicated by the separation line (Fig 2), the mutation carriers tended to have more dense breast tissue, with coarser and lower contrast texture patterns on their mammograms, than did the low-risk women in the age-matched group.

 
Figure 4 shows the distribution of the LDA discriminant scores (ie, LDA outputs) of the mutation carriers and the low-risk cases in the entire group and the age-matched group. The separation between the discriminant scores of the mutation carriers and the low-risk women was evaluated by using ROC analysis. By varying the confidence threshold on the discriminant score (Fig 4), fitted ROC curves were generated, yielding Az values of 0.91 and 0.92 in differentiating between mutation carriers and low-risk women in the entire database and in the age-matched group, respectively. The estimated standard errors for the two Az values were both 0.03. Shown in Figure 5 is the fitted ROC curve, along with the lower and upper bounds of the 95% CI for true-positive fractions at a variety of false-positive fractions, estimated from the binormal distribution of the discriminant scores of the mutation carriers and the low-risk cases in the entire database.



View larger version (24K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 4a. Vertical bar graphs show distribution of the discriminant score of (a) the 142 low-risk cases and the 30 BRCA1 and BRCA2 mutation carriers in the entire group and (b) the 30 BRCA1 and BRCA2 mutation carriers and the 60 age-matched low-risk cases in the age-matched group.

 


View larger version (28K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 4b. Vertical bar graphs show distribution of the discriminant score of (a) the 142 low-risk cases and the 30 BRCA1 and BRCA2 mutation carriers in the entire group and (b) the 30 BRCA1 and BRCA2 mutation carriers and the 60 age-matched low-risk cases in the age-matched group.

 


View larger version (33K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 5. ROC curve, along with its lower and upper 95% CI bounds, generated from LDA outputs in the classification of the BRCA1 and BRCA2 mutation carriers and the low-risk cases in the entire group (172 cases).

 
The density rating distribution of the 30 BRCA1 and BRCA2 mutation carriers and the 60 age-matched low-risk cases (Fig 6) shows that the low-risk women tended to have fatty breasts when compared with the 30 mutation carriers. Approximately half of the 60 age-matched low-risk women had mammograms with a percentage density rating below 30%, whereas approximately one-third of the mutation carriers had mammograms with a percentage density rating below 30%. The relationship between the computer-calculated skewness and the radiologist’s density ratings, as shown in Figure 7, yielded a correlation coefficient of -0.56. This was in agreement with the results obtained by Byng et al (14), who showed the correlation between their computer-calculated skewness and the radiologist’s rating as -.60 in their study of 708 subjects.



View larger version (37K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 6. Vertical bar graph shows the distribution of the radiologist’s assessment of percentage density on a 100-point scale for the 30 mutation carriers and the 60 low-risk women in the age-matched group.

 


View larger version (28K):
[in this window]
[in a new window]
[Download PPT slide]
 
Figure 7. Graph shows the relationship between the radiologist’s assessment of percentage density and a computer-extracted feature (skewness) for the 30 mutation carriers and the 60 low-risk women in the age-matched group.

 

    DISCUSSION
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 APPENDIX
 REFERENCES
 
In the current study, we compared the characteristics of mammographic patterns in BRCA1 and BRCA2 mutation carriers with those in women at low risk for breast cancer. Individuals’ mammographic patterns were characterized on the basis of the analysis of digitized mammograms. As characterized by computer-extracted features, mammographic patterns of carriers of BRCA1 and BRCA2 mutations differed from those of women at low risk for breast cancer; the BRCA1 and BRCA2 mutation carriers tended to have more dense breast tissue, and their mammographic patterns tended to be coarser, with lower contrast than those of low-risk women. The applicability of these individual features in differentiating mammographic patterns between mutation carriers and low-risk women was evaluated in terms of Az values from ROC analysis. These features yielded Az values of 0.68–0.79 in differentiating mammographic patterns between mutation carriers and low-risk cases in the entire database and yielded slightly higher Az values in differentiating between mutation carriers and low-risk cases in the age-matched group. Results from the statistical Z tests showed that the discriminant applicability of these individual computer-extracted features and the linear discriminant function is statistically significantly higher than that of a decision variable with an Az value of 0.5.

It is interesting to note that the texture feature (coarseness) yielded the highest Az value among all four features (skewness, balance, coarseness, and contrast). Statistical tests in which the CLABROC algorithm (28) was used for correlated data showed that the differences in estimated Az values between coarseness and the other three features were not at a statistically significant level (P > .06). However, in differentiating between mammographic patterns of mutation carriers and low-risk women, the applicability level (Az value) of the four features considered together (with LDA) was significantly better (P < .001) than that of individual features on the basis of statistical analysis with the CLABROC algorithm (28).

In the current study, BRCA1 and BRCA2 gene mutation was the only risk factor considered, although there are many other factors associated with breast cancer risk. Among these, age is the most important, with the risk of developing breast cancer increasing with increasing age. To rule out possible bias due to the difference in age distributions of the mutation carriers and the low-risk cases, evaluation of computer analysis was also performed for an aged-matched group. Although the results obtained from the age-matched group were more relevant to this study, the similar Az values and mammographic characteristics obtained from the cases in both the entire group and the age-matched group suggest that the difference in age distributions between the BRCA1 and BRCA2 mutation carriers and low-risk cases did not have a strong influence on the performance of these individual features for this database. The BRCA1 and BRCA2 mutation carriers tended to have denser breasts than did the low-risk women. In addition, their mammographic patterns tended to be coarser, with lower contrast than those of the low-risk women.

As indicated by the Az values (0.91 and 0.92) obtained with LDA, our computerized classification method reached a high level of performance in differentiating between mammographic patterns of mutation carriers and those of low-risk women in both the entire group and the age-matched group. The lower and upper bounds of 95% CIs for the estimated ROC curve generated from the discriminant scores of the mutation carriers and the low-risk women provided evidence that our computerized method can be used for classification. We demonstrated that computerized analysis of mammographic patterns may enable identification of women at high risk for breast cancer. Identification of high-risk women may provide better opportunity for early detection of breast and/or ovarian cancer in these women.

In the current study, skewness was one of the four features used to characterize mammographic density patterns. We have shown that the use of both density and texture features (coarseness and contrast) significantly improved performance in differentiating between mutation carriers and low-risk cases (P < .001), as compared with the use of skewness alone. In general, breast parenchymal patterns can be described in part by the amount of density and in part by the heterogeneity and/or inhomogeneity of the parenchymal patterns. Thus, we believe that a combination of mammographic features will perform better than a single feature (ie, percentage density) in assessing risk. Misclassification of mutation carriers and low-risk women, as indicated by the overlap between the discriminant scores of the mutation carrier and low-risk groups in Figure 4, may result partially from the fact that some mutation carriers and low-risk women have similar mammographic patterns, as characterized by the computer features (Figs 2, 3) and by a radiologist (Fig 6).

In summary, the results of our evaluation suggest that BRCA1 and BRCA2 mutation carriers tend to have dense breasts, and their mammographic patterns tend to be low in contrast and coarse in texture. Analysis of mammograms by using multiple computer-extracted features yielded significantly better performance in differentiating between low-risk women and mutation carriers than that by using individual features only. Furthermore, our objective computerized method enables characterization of the mammographic patterns associated with breast cancer risk and may aid estimation of an individual’s risk of developing breast cancer. Also, such an objective analysis may allow clinicians to monitor changes in breast parenchyma after interventions to reduce breast cancer risk, which may potentially help in assessing the effectiveness of a chemotherapeutic prevention treatment on an individual basis.


    APPENDIX
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 APPENDIX
 REFERENCES
 
A dense ROI tends to have more pixels with high gray-level values (low optical density), yielding a gray-level histogram skewed left. A fatty ROI tends to have more pixels with low gray-level values (high optical density), yielding a gray-level histogram skewed right. Features such as skewness and balance (defined subsequently) of a histogram relative to the mean can be used to quantify the ratio of pixels with high gray-level values to those with low gray-level values relative to the mean, thereby approximating the local tissue composition (fibroglandular tissue vs fat). A dense ROI should yield a negative value of skewness and a value greater than one for balance, whereas a fatty ROI should yield a positive value of skewness and a value less than one for balance. The skewness measure was studied by Byng et al (14) to evaluate the percentage of mammographic breast density. A related balance measure was studied by Tahoces et al (15) to classify mammographic patterns into a Wolfe pattern: Balance = (70% threshold - AVG)/(AVG - 30% threshold), where 70% threshold and 30% threshold refer to the corresponding gray-level value that yields 70% and 30% of the area under the gray-level histogram of a ROI, respectively, and AVG refers to the average gray level of the ROI. Skewness is defined with m3/m23/2, where



and ni is the number of occurrences of gray-level value i. Gh is the highest gray-level value in the ROI (26).

Coarseness and contrast were first proposed by Amadasum and King (20) and were used by Tahoces et al (15) to characterize the Wolfe pattern. The mathematic definitions of the two texture features are given subsequently. The coarseness of a texture is defined by the amount of local gray-level variation. The contrast of a texture is defined by the amount of difference among all gray levels in the ROI and by the amount of local variation in gray level presented in the ROI. Notice that the contrast measure is determined with two terms: the gray-level differences in an ROI weighted by the amount of local variation. Thus, ROIs with similar gray-level differences may have different contrasts, depending on local variation in the ROIs. Conversely, ROIs with the same amount of local variation may have different contrast levels, depending on gray-level differences in the ROIs.

Coarseness (local uniformity [20]) is defined as follows:

Contrast (local contrast [20]) is defined as follows:

where Ng is the total number of different gray levels in the ROI, Gh is the highest gray-level value in the ROI, pi is the probability of occurrence of gray-level value i, N is the width of the ROI, d is the neighborhood size (half of the operating kernel size), n = N - 2d, and the ith entry of s is given as

where {Ni} is the set of pixels with gray level i,

for (p, q) != (0,0) to exclude (x, y), W = (2d + 1)2, and d = 1.


    FOOTNOTES
 
Z.H., M.L.G., and C.E.M. are shareholders in R2 Technology, Los Altos, Calif. It is the policy of the University of Chicago that investigators disclose publicly actual or potential significant financial interests that may appear to be affected by the research activities.

Abbreviations: Az = area under the ROC curve, LDA = linear discriminant analysis, ROC = receiver operating characteristic

Author contributions: Guarantors of integrity of entire study, Z.H., M.L.G.; study concepts, Z.H., O.I.O., M.L.G.; study design, Z.H., O.I.O., M.L.G., B.L.W.; literature research, Z.H., O.I.O.; clinical studies, W.Z., S.A.C.; data acquisition, all authors; data analysis/interpretation, Z.H., M.L.G.; statistical analysis, Z.H., C.E.M.; manuscript editing and preparation, Z.H., M.L.G.; manuscript definition of intellectual content, Z.H., M.L.G., O.I.O., C.E.M.; manuscript revision/review and final version approval, all authors.


    REFERENCES
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 APPENDIX
 REFERENCES
 

  1. Claus EB, Risch N, Thompson WD. Genetic analysis of breast cancer in the cancer and steroid hormone study. Am J Hum Genet 1991; 48:232-242.[Medline]
  2. Newman B, Austin MA, Lee M, King MC. Inheritance of human breast cancer: evidence for autosomal dominant transmission in high risk families. Proc Natl Acad Sci U S A 1988; 85:3044-3048.[Abstract/Free Full Text]
  3. Easton DF, Ford D, Bishop TD. Breast and ovarian cancer incidence in BRCA1-mutation carriers. Am J Hum Genet 1995; 56:256-271.
  4. Boyd NF, Byng J, Jong R. Quantitative classification of mammographic densities and breast cancer risk: results from the Canadian National Breast Screening Study. J Natl Cancer Inst 1995; 87:670-675.[Abstract/Free Full Text]
  5. Saftlas AF, Hoover RN, Brinton LA, et al. Mammographic densities and risk of breast cancer. Cancer 1991; 67:2833-2838.[CrossRef][Medline]
  6. Byrne C, Schairer C, Wolfe J, et al. Mammographic features and breast cancer risk: effects with time, age, and menopause status. J Natl Cancer Inst 1995; 87:1622-1629.[Abstract/Free Full Text]
  7. Wolfe JN, Saftlas AF, Salane M. Mammographic parenchymal patterns and quantitative evaluation of mammographic densities: a case-control study. AJR Am J Roentgenol 1987; 148:1087-1092.[Abstract/Free Full Text]
  8. Hedenfalk I, Duggan D, Chen Y, et al. Gene-expression profiles in hereditary breast cancer. N Engl J Med 2001; 344:539-548.[Abstract/Free Full Text]
  9. Ford D, Easton DF, Bishop DT, Narod SA, Goldgar DE. Risk of cancer in BRCA1-mutation carriers. Lancet 1994; 343:692-695.[CrossRef][Medline]
  10. Tirkkonen M, Johannsson O, Agnarsson BA, et al. Distinct somatic genetic changes associated with tumor progression in carriers of BRCA1 and BRCA2 germ-line mutations. Cancer Res 1997; 57:1222-1227.[Abstract/Free Full Text]
  11. Marcus JN, Watson P, Page DL, et al. Hereditary breast cancer: pathobiology, prognosis, and BRCA1 and BRCA2 gene linkage. Cancer 1996; 77:697-709.[CrossRef][Medline]
  12. Wolfe J. Breast patterns as an index of risk for developing breast cancer. AJR Am J Roentgenol 1976; 126:1130-1139.[Abstract]
  13. Warner E, Lockwood G, Math M, Tritchler D, Boyd NF. The risk of breast cancer associated with mammographic parenchymal patterns: a meta-analysis of the published literature to examine the effect of method of classification. Cancer Detect Prev 1992; 16:67-72.[Medline]
  14. Byng JW, Yaffe MJ, Lockwood GA, et al. Automated analysis of mammographic densities and breast carcinoma risk. Cancer 1997; 88:66-74.
  15. Tahoces P, Correa J, Souto M, Gomes L, Vidal J. Computer-assisted diagnosis: the classification of mammographic breast parenchymal patterns. Phys Med Biol 1995; 40:103-117.[CrossRef][Medline]
  16. Huo Z, Giger ML, Wolverton DE, et al. Computerized analysis of mammographic parenchymal patterns for breast cancer risk assessment: feature selection. Med Phys 2000; 27:4-12.[CrossRef][Medline]
  17. Gail MH, Benichou J. Assessing the risk of breast cancer in individuals. In: DeVita VT, Hellman S, Rosenberg SA, eds. Cancer prevention. Philadelphia, Pa.: Lippincott, 1992; 1-15.
  18. Fisher B, Costantino JP, Wicherham DL, et al. Tamoxifen for prevention of breast cancer: report from the National Surgical Adjuvant Breast and Bowel Project P-1 Study. J Natl Cancer Inst 1998; 90:1371-1388.[Abstract/Free Full Text]
  19. Claus EB, Risch N, Thompson WD. Autosomal dominant inheritance of early-onset breast cancer: Implications for risk prediction. Cancer 1993; 73:643-651.
  20. Amadasum M, King R. Texture features corresponding to texture properties. IEEE Trans Syst Man Cybernetics 1989; 19:1264-1274.[CrossRef]
  21. Lachenbruch PL. Discriminant analysis London, England: Hafner, 1975.
  22. Chang J, Yang WT, Choo HF. Mammography in Asian patients with BRCA1 mutations. Lancet 1999; 353:2070-2071.[Medline]
  23. Helvie MA, Roubidoux MA, Weber BL, Merajver SD. Mammography of breast carcinoma in women who have mutations of the breast cancer gene BRCA1: initial experience. AJR Am J Roentgenol 1997; 168:1599-1602.[Abstract/Free Full Text]
  24. Metz CE. ROC methodology in radiologic imaging. Invest Radiol 1986; 21:720-733.[Medline]
  25. Metz CE. Some practical issues of experimental design and data analysis in radiological ROC studies. Invest Radiol 1989; 24:234-245.[Medline]
  26. Metz CE, Herman BA, Shen J. Maximum-likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data. Stat Med 1998; 17:1033-1053.[CrossRef][Medline]
  27. Hays WL. Statistics Philadelphia, Pa: Harcourt Brace College, 1994.
  28. Metz CE, Herman BA, Roe CA. Statistical comparison of two ROC-curve estimates obtained from partially-paired datasets. Med Decis Making 1998; 18:110-121.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
G. J. R. Porter, A. J. Evans, E. J. Cornford, H. C. Burrell, J. J. James, A. H. S. Lee, and J. Chakrabarti
Influence of Mammographic Parenchymal Pattern in Screening-Detected and Interval Invasive Breast Cancers on Pathologic Features, Mammographic Features, and Patient Survival
Am. J. Roentgenol., March 1, 2007; 188(3): 676 - 683.
[Abstract] [Full Text] [PDF]


Home page
Cancer Res.Home page
G. Mitchell, A. C. Antoniou, R. Warren, S. Peock, J. Brown, R. Davies, J. Mattison, M. Cook, I. Warsi, D. G. Evans, et al.
Mammographic Density and Breast Cancer Risk in BRCA1 and BRCA2 Mutation Carriers
Cancer Res., February 1, 2006; 66(3): 1866 - 1872.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
M. Kriege, C. T.M. Brekelmans, C. Boetes, P. E. Besnard, H. M. Zonderland, I. M. Obdeijn, R. A. Manoliu, T. Kok, H. Peterse, M. M.A. Tilanus-Linthorst, et al.
Efficacy of MRI and Mammography for Breast-Cancer Screening in Women with a Familial or Genetic Predisposition
N. Engl. J. Med., July 29, 2004; 351(5): 427 - 437.
[Abstract] [Full Text] [PDF]


Home page
JNCI J Natl Cancer InstHome page
J. Cuzick, J. Warwick, E. Pinney, R. M. L. Warren, and S. W. Duffy
Tamoxifen and Breast Density in Women at Increased Risk of Breast Cancer
J Natl Cancer Inst, April 21, 2004; 96(8): 621 - 628.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. A. Harvey and V. E. Bovbjerg
Quantitative Assessment of Mammographic Breast Density: Relationship with Breast Cancer Risk
Radiology, January 1, 2004; 230(1): 29 - 41.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2252010845v1
225/2/519    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Huo, Z.
Right arrow Articles by Cummings, S. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Huo, Z.
Right arrow Articles by Cummings, S. A.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE