Assessment of Aortoiliac and Renal Arteries: MR Angiography with Parallel Acquisition versus Conventional MR Angiography and Digital Subtraction Angiography

Table E1. Measurements of Signal-to-Noise and Contrast-to-Noise Ratios for the Aortoiliac and Renal Arteries on Conventional and Fast MR Angiography Images in 40 Patients

 

Signal-to-Noise Ratio

 

Contrast-to-Noise Ratio

 

Conventional MRA

Fast MRA

P Value

 

Conventional MRA

Fast MRA

P Value

Suprarenal aorta

66.2 ± 13.2

29.1 ± 5.8

.001

 

51.6 ± 11.3

24.1 ± 4.8

.001

Infrarenal aorta

64.5 ± 13.7

40.5 ± 9.3

.001

 

49.6 ± 13.6

34.2 ± 8.9

.001

Left renal artery, proximal segment

64.4 ± 16.0

33.2 ± 6.8

.001

 

47.8 ± 13.7

27.2 ± 5.5

.001

Left renal artery, middle segment

62.3 ± 15.8

34.0 ± 7.5

.001

 

48.0 ± 12.5

27.9 ± 4.8

.001

Left renal artery, distal segment

61.1 ± 13.5

32.0 ± 7.3

.001

 

46.3 ± 13.2

30.4 ± 5.4

.001

Right renal artery, proximal segment

65.1 ± 13.2

33.3 ± 5.3

.001

 

48.8 ± 11.1

27 ± 4.4

.001

Right renal artery, middle segment

63.7 ± 15.1

32.3 ± 6.9

.001

 

46.4 ± 12.6

27.9 ± 5.3

.001

Right renal artery, distal segment

62.9 ± 14.3

35.2 ± 7.2

.001

 

45.8 ± 12.3

27.5 ± 4.6

.001

Accessory renal artery, proximal segment

59.1 ± 18.8

29.4 ± 5.6

.001

 

43.4 ± 15.0

23.6 ± 4.5

.001

Accessory renal artery, middle segment

62.8 ± 19.1

27.2 ± 5.5

.001

 

47.7 ± 14.0

21.5 ± 4.9

.001

Accessory renal artery, distal segment

63.5 ± 13.7

30.3 ± 5.9

.001

 

48.8 ± 14.3

25.3 ± 5.5

.001

Left common iliac artery

65.1 ± 15.3

42.8 ± 8.6

.001

 

49.4 ± 15.2

35.9 ± 7.9

.001

Left external iliac artery, proximal

60.1 ± 13.0

43.5 ± 13.0

.001

 

43.8 ± 10.2

36.6 ± 12.3

.007

Left external iliac artery, distal

61.3 ± 15.4

44.2 ± 11.4

.001

 

43.3 ± 13.4

35.2 ± 10.5

.005

Left internal iliac artery

51.5 ± 11.1

35.9 ± 6.1

.001

 

35.4 ± 9.5

29.1 ± 4.7

.001

Right common iliac artery

64.2 ± 14.5

42.2 ± 7.5

.001

 

49.4 ± 13.7

35.5 ± 6.4

.001

Right external iliac artery, proximal

61.0 ± 12.5

38.1 ± 6.5

.001

 

44.7 ± 9.2

31.2 ± 5.5

.001

Right external iliac artery, distal

60.8 ± 12.1

42.2 ± 7.6

.001

 

44.9 ± 9.0

32.1 ± 6.7

.001

Right internal iliac artery

55.9 ± 10.1

38.4 ± 7.0

.001

 

40.3 ± 6.9

30.4 ± 4.9

.001

Left common femoral artery

62.3 ± 18.8

44.9 ± 10.2

.001

 

45.7 ± 15.7

37.1 ± 8.6

.002

Right common femoral artery

60.3 ± 12.4

47.4 ± 12.4

.001

 

42.7 ± 9.3

35.1 ± 10.2

.001

Note.—Numbers are mean ± standard deviation. P values < .0028 are considered statistically significant. MRA = MR angiography.

 

Table E2. Image Quality of the Aortoiliac and Renal Arteries as Assessed by Two Independent Readers on Conventional and Fast MR Angiographic Images in 40 Patients

Table E2

Note.—Grade 1, not visible (no diagnostic information can be obtained from the images); 2, poor visibility (image quality of vessel is degraded by low signal intensity and motion-induced blurring artifacts); 3, moderate visibility (image quality of vessel is degraded by low signal intensity or motion-induced blurring artifacts); 4, good visibility (high signal intensity and slight motion-induced blurring artifacts); 5, excellent visibility (high signal intensity, no motion-induced blurring artifacts). P values < .0028 are considered statistically significant after Bonferroni correction. MRA = MR angiography.

 

Table E3. Performance of Conventional and Fast MR Angiography Compared with Digital Subtraction Angiography as Assessed by Two Independent Readers in the Detection of Hemodynamically Significant Stenoses in 40 Patients

Table E3

Note.—Numbers in parentheses are 95% confidence intervals. FN = false negative, FP = false positive, MRA = MR angiography, NPV = negative predictive value, PPV = positive predictive value, R1 = Reader 1, R2 = Reader 2, TN = true negative, TP = true positive.





This Article
Right arrow Abstract
Right arrow Full Text
Right arrow Submit a response
Services
Right arrow Email this article to a friend
Right arrow Alert me to new issues of the journal
Right arrow reprints & permissions


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE