© RSNA, 2007
Table E1. Measurements of Signal-to-Noise and Contrast-to-Noise Ratios for the Aortoiliac and Renal Arteries on Conventional and Fast MR Angiography Images in 40 Patients
|
|
Signal-to-Noise Ratio |
|
Contrast-to-Noise Ratio |
||||
|
|
Conventional MRA |
Fast MRA |
P Value |
|
Conventional MRA |
Fast MRA |
P Value |
|
Suprarenal
aorta |
66.2 ± 13.2 |
29.1 ± 5.8 |
.001 |
|
51.6 ± 11.3 |
24.1 ± 4.8 |
.001 |
|
Infrarenal aorta |
64.5 ± 13.7 |
40.5 ± 9.3 |
.001 |
|
49.6 ± 13.6 |
34.2 ± 8.9 |
.001 |
|
Left renal
artery, proximal segment |
64.4 ± 16.0 |
33.2 ± 6.8 |
.001 |
|
47.8 ± 13.7 |
27.2 ± 5.5 |
.001 |
|
Left renal
artery, middle segment |
62.3 ± 15.8 |
34.0 ± 7.5 |
.001 |
|
48.0 ± 12.5 |
27.9 ± 4.8 |
.001 |
|
Left renal
artery, distal segment |
61.1 ± 13.5 |
32.0 ± 7.3 |
.001 |
|
46.3 ± 13.2 |
30.4 ± 5.4 |
.001 |
|
Right
renal artery, proximal segment |
65.1 ± 13.2 |
33.3 ± 5.3 |
.001 |
|
48.8 ± 11.1 |
27 ± 4.4 |
.001 |
|
Right
renal artery, middle segment |
63.7 ± 15.1 |
32.3 ± 6.9 |
.001 |
|
46.4 ± 12.6 |
27.9 ± 5.3 |
.001 |
|
Right
renal artery, distal segment |
62.9 ± 14.3 |
35.2 ± 7.2 |
.001 |
|
45.8 ± 12.3 |
27.5 ± 4.6 |
.001 |
|
Accessory
renal artery, proximal segment |
59.1 ± 18.8 |
29.4 ± 5.6 |
.001 |
|
43.4 ± 15.0 |
23.6 ± 4.5 |
.001 |
|
Accessory
renal artery, middle segment |
62.8 ± 19.1 |
27.2 ± 5.5 |
.001 |
|
47.7 ± 14.0 |
21.5 ± 4.9 |
.001 |
|
Accessory
renal artery, distal segment |
63.5 ± 13.7 |
30.3 ± 5.9 |
.001 |
|
48.8 ± 14.3 |
25.3 ± 5.5 |
.001 |
|
Left
common iliac artery |
65.1 ± 15.3 |
42.8 ± 8.6 |
.001 |
|
49.4 ± 15.2 |
35.9 ± 7.9 |
.001 |
|
Left
external iliac artery, proximal |
60.1 ± 13.0 |
43.5 ± 13.0 |
.001 |
|
43.8 ± 10.2 |
36.6 ± 12.3 |
.007 |
|
Left
external iliac artery, distal |
61.3 ± 15.4 |
44.2 ± 11.4 |
.001 |
|
43.3 ± 13.4 |
35.2 ± 10.5 |
.005 |
|
Left
internal iliac artery |
51.5 ± 11.1 |
35.9 ± 6.1 |
.001 |
|
35.4 ± 9.5 |
29.1 ± 4.7 |
.001 |
|
Right
common iliac artery |
64.2 ± 14.5 |
42.2 ± 7.5 |
.001 |
|
49.4 ± 13.7 |
35.5 ± 6.4 |
.001 |
|
Right external
iliac artery, proximal |
61.0 ± 12.5 |
38.1 ± 6.5 |
.001 |
|
44.7 ± 9.2 |
31.2 ± 5.5 |
.001 |
|
Right
external iliac artery, distal |
60.8 ± 12.1 |
42.2 ± 7.6 |
.001 |
|
44.9 ± 9.0 |
32.1 ± 6.7 |
.001 |
|
Right
internal iliac artery |
55.9 ± 10.1 |
38.4 ± 7.0 |
.001 |
|
40.3 ± 6.9 |
30.4 ± 4.9 |
.001 |
|
Left
common femoral artery |
62.3 ± 18.8 |
44.9 ± 10.2 |
.001 |
|
45.7 ± 15.7 |
37.1 ± 8.6 |
.002 |
|
Right
common femoral artery |
60.3 ± 12.4 |
47.4 ± 12.4 |
.001 |
|
42.7 ± 9.3 |
35.1 ± 10.2 |
.001 |
Note.—Numbers are mean ± standard deviation. P values < .0028 are considered statistically significant. MRA = MR angiography.
Table E2. Image Quality of the Aortoiliac and Renal Arteries as Assessed by Two Independent Readers on Conventional and Fast MR Angiographic Images in 40 Patients

Note.—Grade 1, not visible (no diagnostic information can be obtained from the images); 2, poor visibility (image quality of vessel is degraded by low signal intensity and motion-induced blurring artifacts); 3, moderate visibility (image quality of vessel is degraded by low signal intensity or motion-induced blurring artifacts); 4, good visibility (high signal intensity and slight motion-induced blurring artifacts); 5, excellent visibility (high signal intensity, no motion-induced blurring artifacts). P values < .0028 are considered statistically significant after Bonferroni correction. MRA = MR angiography.
Table E3. Performance of Conventional and Fast MR Angiography Compared with Digital Subtraction Angiography as Assessed by Two Independent Readers in the Detection of Hemodynamically Significant Stenoses in 40 Patients

Note.—Numbers in parentheses are 95% confidence intervals. FN = false negative, FP = false positive, MRA = MR angiography, NPV = negative predictive value, PPV = positive predictive value, R1 = Reader 1, R2 = Reader 2, TN = true negative, TP = true positive.
| ||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |