Focal Liver Lesion Detection and Characterization with Diffusion-weighted MR Imaging: Comparison with Standard Breath-hold T2-weighted Imaging



Table E1. Detection Rate of 208 Focal Liver Lesions in 53 Patients with Diffusion-weighted and T2-weighted Imaging Stratified by Location in Liver and Averaged for Two Independent Observers  

 

 

Right Liver Lobe (n = 125)

Left Liver Lobe (n = 83)

P Value

Diffusion-weighted imaging

110.5 (88.4)

71.5 (86.1)

.509

T2-weighted imaging

94.0 (75.2)

51.0 (61.4)

.037

P Value

.0022

.00013

 

 

Note.—Three lesions bridging the right and left lobes were excluded. Numbers in parentheses are percentages.

 


Table E2. Number and Size of Missed and Indeterminate Focal Liver Lesions on Diffusion-weighted Images and T2-weighted Images Read by Two Independent Observers

 

 

Observer 1

Observer 2

Images

No. of Lesions

Size (cm)*

No. of Lesions

Size (cm)*

 

Missed Focal Liver Lesions

Diffusion-weighted

22

1.7 (1.0–5.3)

30

2.0 (1.0–8.0)

T2-weighted

62

1.7 (1.0–6.9)

64

2.0 (1.0–12.2)

 

Indeterminate Focal Liver Lesions

Diffusion-weighted

10

1.7 (1.0–3.7)

11

1.6 (1.0–3.7)

T2-weighted

9

2.4 (1.4–4.6)

12

3.6 (1.1–12.8)

 

* Values are means, with ranges in parentheses.





This Article
Right arrow Abstract
Right arrow Full Text
Right arrow Submit a response
Services
Right arrow Email this article to a friend
Right arrow Alert me to new issues of the journal
Right arrow reprints & permissions


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE