Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published online before print September 13, 2002, 10.1148/radiol.2251011664

(Radiology 2002;225:597.)

A more recent version of this article appeared on November 1, 2002
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow All Versions of this Article:
2251011664v1
225/2/597    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Martin, D. R.
Right arrow Articles by Acheson, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Martin, D. R.
Right arrow Articles by Acheson, C.
© RSNA, 2002

Technical Developments

MR Colonography: Development of Optimized Method with ex Vivo and in Vivo Systems1

Diego R. Martin, MD, PhD, Ming Yang, MD, David Thomasson, PhD and Craig Acheson, RT

1 From the Department of Abdominal Imaging, West Virginia University School of Medicine, Robert C. Byrd Health Sciences Center, PO Box 9235, Morgantown, WV 26505-9235. Received October 11, 2001; revision requested January 4, 2002; revision received February 20; accepted May 15. Address correspondence to D.R.M. (e-mail: dmartin@hsc.wvu.edu).

An ex vivo magnetic resonance (MR) colonographic system with a bovine colon with polyps of predetermined dimensions was developed for evaluation and optimization of different combinations of imaging sequences and intraluminal contrast agents. Findings were then applied during in vivo testing in human subjects. The results show that optimized contrast and lesion conspicuity and minimized motion artifacts can be obtained with true fast imaging with steady-state precession combined with water as an intraluminal contrast agent.

© RSNA, 2002

Index terms: Colon, MR, 75.121412, 75.121419, 75.12143 • Magnetic resonance (MR), experimental studies, 75.121412, 75.121419, 75.12143




This article has been cited by other articles:


Home page
RadiologyHome page
K. Tanitame, K. Sasaki, T. Sone, S. Uyama, M. Sumida, T. Ichiki, and K. Ito
Anterior Chamber Configuration in Patients with Glaucoma: MR Gonioscopy Evaluation with Half-Fourier Single-Shot RARE Sequence and Microscopy Coil
Radiology, October 1, 2008; 249(1): 294 - 300.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
I. Yamada, S. Okabe, M. Enomoto, K. Sugihara, N. Yoshino, A. Tetsumura, J. Kumagai, and H. Shibuya
Colorectal Carcinoma: In Vitro Evaluation with High-Spatial-Resolution 3D Constructive Interference in Steady-State MR Imaging
Radiology, December 19, 2007; (2007) 2462070128.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
C. A. Kuehle, P. Veit, G. Antoch, F. Grabellus, P. Robert, T. Beyer, and C. U. Herborn
Contrast-Enhanced Dark Lumen PET/CT and MR Colonography in a Rodent Polyp Model: Initial Results with Histopathologic Correlation
Am. J. Roentgenol., October 1, 2005; 185(4): 1045 - 1047.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2002 by the Radiological Society of North America.