Vascular and Interventional Radiology |
1 From the Department of Nephrology (J.H.M.S., W.A.M.A.v.d.M., P.J.B.), Department of Radiology, Image Sciences Institute (C.B., O.E.H.E., C.J.G.B., J.J.Z., W.P.T.M.M.), and Julius Center for Health Sciences and Primary Care (S.K.), University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, the Netherlands. Received May 2, 2001; revision requested June 18; final revision received April 5, 2002; accepted May 8. J.H.M.S. supported by grant C.97.1643 from the Dutch Kidney Foundation. Address correspondence to C.J.G.B. (e-mail: c.j.g.bakker@azu.nl).
PURPOSE: To compare flow-interrupted contrast materialenhanced magnetic resonance (MR) angiography with conventional digital subtraction angiography (DSA) for hemodialysis access imaging.
MATERIALS AND METHODS: Twenty-two accesses (14 arteriovenous grafts [AVGs], eight arteriovenous fistulas [AVFs]) in 18 consecutive patients were imaged with flow-interrupted contrast-enhanced MR angiography and subsequent conventional DSA. MR image quality was assessed as excellent, good, or nondiagnostic. Anastomotic diameters in AVGs and postanastomotic diameters in AVFs were measured in consideration of an adjacent normal segment. Reductions in the diameter of the lumen and interobserver differences were analyzed with method comparison as described by Bland and Altman and expressed as the mean difference with its 95% confidence limits (CLs) (mean ± 2 SDs).
RESULTS: Image quality obtained with flow-interrupted contrast-enhanced MR angiography was considered excellent in 73% (16 of 22) and good in 23% (5 of 22). Method comparison analysis between MR angiography and DSA indicated a mean difference of 3.2% (95% CLs: -26.7%, 33.1%) for observer 1 and 4.1% (95% CLs: -23.8%, 32.1%) for observer 2. Interobserver analysis at MR angiography indicated a mean difference of 3.2% (95% CLs: -28.8%, 35.2%), and that at DSA indicated a mean difference of 3.6% (95% CLs: -9.4%, 16.7%).
CONCLUSION: Image quality and anatomic depiction with flow-interrupted contrast-enhanced MR angiography and with DSA were comparable.
© RSNA, 2002
Index terms: Dialysis, shunts, 91.4539 Digital subtraction angiography, comparative studies, 91.122, 91.12942 Fistula, arteriovenous, 91.457 Grafts, interventional procedures Magnetic resonance (MR), vascular studies, 91.12942, 91.12943, 91.12944
This article has been cited by other articles:
![]() |
F. Stepansky, E. M. Hecht, R. Rivera, L. E. Hirsh, B. Taouli, M. Kaur, and V. S. Lee Dynamic MR Angiography of Upper Extremity Vascular Disease: Pictorial Review RadioGraphics, January 1, 2008; 28(1): e28 - e28. [Abstract] [Full Text] |
||||
![]() |
C. Leon and A. Asif Arteriovenous Access and Hand Pain: The Distal Hypoperfusion Ischemic Syndrome Clin. J. Am. Soc. Nephrol., January 1, 2007; 2(1): 175 - 183. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Zhang, E. M. Hecht, T. Maldonado, and V. S. Lee Time-Resolved 3D MR Angiography with Parallel Imaging for Evaluation of Hemodialysis Fistulas and Grafts: Initial Experience. Am. J. Roentgenol., May 1, 2006; 186(5): 1436 - 1442. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. L. Froger, L. E. M. Duijm, Y. S. Liem, A. V. Tielbeek, A. B. Donkers-van Rossum, P. Douwes-Draaijer, P. W. M. Cuypers, J. Buth, and H. C. M. van den Bosch Stenosis Detection with MR Angiography and Digital Subtraction Angiography in Dysfunctional Hemodialysis Access Fistulas and Grafts Radiology, January 1, 2005; 234(1): 284 - 291. [Abstract] [Full Text] [PDF] |
||||