1 From the Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S Kingshighway Blvd, St Louis, MO 63110. Received February 13, 2002; revision requested April 17; final revision received August 9; accepted September 27. Address correspondence to the author (e-mail: baet@mir.wustl.edu).
PURPOSE: To investigate pharmacokinetic and physiologic factors that determine the time to peak intravenous contrast medium enhancement in computed tomographic (CT) and magnetic resonance (MR) angiography in the porcine midabdominal aorta.
MATERIALS AND METHODS: Four pigs were imaged repeatedly in seven to eight sets: For each set, 20 dynamic CT scans were obtained at a fixed aortic level after intravenous injection of contrast medium. From a physiologically based compartment model, aortic contrast enhancement curves were generated by varying contrast medium injection duration from 1 to 40 seconds. Contrast enhancement curves and times to peak aortic enhancement from the experiment and model were compared. Time to peak aortic enhancement obtained from the injection with the shortest duration was considered the time to peak test bolus contrast enhancement. Mathematic and pharmacokinetic analyses were performed to investigate factors that determine peak enhancement.
RESULTS: Empiric and compartmental model times to peak aortic enhancement were in good agreement. Time to peak aortic enhancement corresponded to the weighted sum of injection duration and time to peak test bolus enhancement. With increasing injection duration, the relative contribution of injection duration to peak aortic enhancement time increased. When injection duration was longer than time to peak test bolus enhancement, time to peak aortic enhancement increased linearly with injection duration and occurred shortly after completion of injection. However, when injection duration was shorter than time to peak test bolus enhancement, time to peak aortic enhancement was determined predominantly by time to peak test bolus enhancement and only gradually increased with injection duration.
CONCLUSION: Time to peak aortic enhancement is determined by the relative contributions of injection duration and contrast medium traveling time and may well be explained by contrast medium volumetric inflow and recirculation physiology.
© RSNA, 2003
Index terms: Animals Aorta, CT, 89.12112, 89.12114 Aorta, MR, 89.12142, 89.12143 Contrast media, experimental studies Model, mathematical
This article has been cited by other articles:
![]() |
K. Lin, Z.-Q. Zhang, J.-Y. Sun, Z.-M. Fan, and B. Lu Low Injection Rate for 3D Moving-Table Bolus-Chase MR Angiography: Initial Experience with 3-T Imaging to Allay Venous Contamination in the Calf Am. J. Roentgenol., December 1, 2008; 191(6): 1734 - 1739. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. T. Bae, A. J. Shah, S. S. Shang, J. H. Wang, S. Chang, M. Kanematsu, and C. F. Hildebolt Aortic and Hepatic Contrast Enhancement with Abdominal 64-MDCT in Pediatric Patients: Effect of Body Weight and Iodine Dose Am. J. Roentgenol., November 1, 2008; 191(5): 1589 - 1594. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Yanaga, K. Awai, T. Nakaura, T. Namimoto, S. Oda, Y. Funama, and Y. Yamashita Optimal Contrast Dose for Depiction of Hypervascular Hepatocellular Carcinoma at Dynamic CT Using 64-MDCT Am. J. Roentgenol., April 1, 2008; 190(4): 1003 - 1009. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. T. Bae, B. A. Seeck, C. F. Hildebolt, C. Tao, F. Zhu, M. Kanematsu, and P. K. Woodard Contrast Enhancement in Cardiovascular MDCT: Effect of Body Weight, Height, Body Surface Area, Body Mass Index, and Obesity Am. J. Roentgenol., March 1, 2008; 190(3): 777 - 784. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Kanematsu, S. Goshima, H. Kondo, K. T. Bae, K. Awai, and Y. Yamashita How Should We Optimize Bolus Tracking with Multidetector CT of the Abdomen? Radiology, February 1, 2008; 246(2): 643 - 645. [Full Text] [PDF] |
||||
![]() |
L. L. Chu, B. N. Joe, A. C. A. Westphalen, E. M. Webb, F. V. Coakley, and B. M. Yeh Patient-specific Time to Peak Abdominal Organ Enhancement Varies with Time to Peak Aortic Enhancement at MR Imaging Radiology, December 1, 2007; 245(3): 779 - 787. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Wittram How I Do It: CT Pulmonary Angiography Am. J. Roentgenol., May 1, 2007; 188(5): 1255 - 1261. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. G. Vrachliotis, K. G. Bis, A. Haidary, R. Kosuri, M. Balasubramaniam, M. Gallagher, G. Raff, M. Ross, B. O'Neil, and W. O'Neill Atypical Chest Pain: Coronary, Aortic, and Pulmonary Vasculature Enhancement at Biphasic Single-Injection 64-Section CT Angiography Radiology, May 1, 2007; 243(2): 368 - 376. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Sultana, K. Awai, Y. Nakayama, T. Nakaura, D. Liu, M. Hatemura, Y. Funama, S. Morishita, and Y. Yamashita Hypervascular Hepatocellular Carcinomas: Bolus Tracking with a 40-Detector CT Scanner to Time Arterial Phase Imaging Radiology, April 1, 2007; 243(1): 140 - 147. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. S. Kuzo, R. A. Pooley, J. E. Crook, M. G. Heckman, and T. C. Gerber Measurement of Caval Blood Flow with MRI During Respiratory Maneuvers: Implications for Vascular Contrast Opacification on Pulmonary CT Angiographic Studies Am. J. Roentgenol., March 1, 2007; 188(3): 839 - 842. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. H. Lee, J. M. Goo, H. J. Lee, K. G. Kim, J.-G. Im, and K. T. Bae Determination of Optimal Timing Window for Pulmonary Artery MDCT Angiography Am. J. Roentgenol., February 1, 2007; 188(2): 313 - 317. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. T. Bae, C. Tao, S. Gurel, C. Hong, F. Zhu, T. A. Gebke, M. Milite, and C. F. Hildebolt Effect of Patient Weight and Scanning Duration on Contrast Enhancement during Pulmonary Multidetector CT Angiography Radiology, February 1, 2007; 242(2): 582 - 589. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Goshima, M. Kanematsu, H. Kondo, R. Yokoyama, T. Miyoshi, H. Kato, Y. Tsuge, Y. Shiratori, H. Hoshi, M. Onozuka, et al. Pancreas: Optimal Scan Delay for Contrast-enhanced Multi-Detector Row CT Radiology, October 1, 2006; 241(1): 167 - 174. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Goshima, M. Kanematsu, H. Kondo, R. Yokoyama, T. Miyoshi, H. Nishibori, H. Kato, H. Hoshi, M. Onozuka, and N. Moriyama MDCT of the liver and hypervascular hepatocellular carcinomas: optimizing scan delays for bolus-tracking techniques of hepatic arterial and portal venous phases. Am. J. Roentgenol., July 1, 2006; 187(1): W25 - W32. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. T. Bae, F. Cademartiri, and G. P. Krestin Test-Bolus versus Bolus-tracking Techniques for CT Angiographic Timing * Drs Cademartiri and Krestin respond: Radiology, July 1, 2005; 236(1): 369 - 370. [Full Text] [PDF] |
||||
![]() |
K. T. Bae, H. Q. Tran, and J. P. Heiken Uniform Vascular Contrast Enhancement and Reduced Contrast Medium Volume Achieved by Using Exponentially Decelerated Contrast Material Injection Method Radiology, June 1, 2004; 231(3): 732 - 736. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |