Published online before print October 21, 2004, 10.1148/radiol.2333031710

(Radiology 2004;233:774.)

A more recent version of this article appeared on December 1, 2004
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow All Versions of this Article:
2333031710v1
233/3/774    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kuehne, T.
Right arrow Articles by Gutberlet, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kuehne, T.
Right arrow Articles by Gutberlet, M.
© RSNA, 2004

Experimental Studies

Catheter Visualization with Resonant Markers at MR Imaging–guided Deployment of Endovascular Stents in Swine1

Titus Kuehne, MD, Steffen Weiss, PhD, Florian Brinkert, MD, Jochen Weil, MD, Sevim Yilmaz, MD, Boris Schmitt, MD, Peter Ewert, MD, Peter Lange, MD and Matthias Gutberlet, MD

1 From the Departments of Congenital Heart Disease and Pediatric Cardiology, German Heart Institute, Augustenburger Platz 1, Berlin 13037, Germany (T.K., S.Y., B.S., P.E., P.L.); Philips Research Laboratories, Hamburg, Germany (S.W.); Department of Pediatric Cardiology, University Hospital Eppendorf, Hamburg, Germany (F.B., J.W.); and Department of Diagnostic Radiology and Nuclear Medicine, Charité, Humboldt University, Berlin, Germany (M.G.). Received October 28, 2003; revision requested January 16, 2004; revision received March 11; accepted April 1. Supported in part by the German Bundesministerium für Bildung und Forschung and the Deutsche Forschungsgemeinschaft. Address correspondence to T.K. (e-mail: titus.kuehne@dhzb.de).

PURPOSE: To evaluate resonant circuits as markers for magnetic resonance (MR) imaging–guided placement of nitinol stents.

MATERIALS AND METHODS: The study was approved by the institutional animal research committee and complied with National Institutes of Health guidelines for care and use of laboratory animals. Resonant circuits similar to catheter markers used at conventional angiography were placed proximally and distally to a nitinol stent in a stent delivery system. Resonant circuits were tested in vitro and in vivo for signal intensity levels that would enable visualization during MR imaging–guided stent deployment. Experiments were conducted by using real-time imaging with a 1.5-T unit. Stents (n = 9) were deployed in the vena cava (n = 2), abdominal aorta (n = 2), isthmus of the aorta (n = 2), and carotid (n = 2) and iliac (n = 1) arteries in five pigs. After intervention, the site of the stent was investigated with balanced fast field-echo MR imaging and contrast material–enhanced MR angiography. Blood flow velocities were measured in the stent lumen and next to the stent with velocity-encoded cine MR imaging. Level of agreement was determined with Bland-Altman analysis.

RESULTS: During all interventions, resonant circuits provided highly visible MR signal that allowed fast and reliable visualization of the stent delivery system. Borders of loaded stents were clearly marked, which allowed precise stent placement in all experiments. Balanced fast field-echo MR imaging and contrast-enhanced MR angiography provided information about immediate postintervention position. Positions depicted on MR images were found accurate at postmortem examination. Results of Bland-Altman analysis showed good agreement between blood flow velocities measured in and next to the stent lumen, with a mean difference of –9 cm/sec ± 5 (standard deviation).

CONCLUSION: Resonant circuits are well suited for use at deployment of endovascular stents.

© RSNA, 2004

Index terms: Animals • Arteries, grafts and prostheses • Catheters and catheterization, technology • Magnetic resonance (MR), guidance, 56.1294, 94.1294 • Stents and prostheses




This article has been cited by other articles:


Home page
CirculationHome page
J. J. Krueger, P. Ewert, S. Yilmaz, D. Gelernter, B. Peters, K. Pietzner, A. Bornstedt, B. Schnackenburg, H. Abdul-Khaliq, E. Fleck, et al.
Magnetic Resonance Imaging-Guided Balloon Angioplasty of Coarctation of the Aorta: A Pilot Study
Circulation, February 28, 2006; 113(8): 1093 - 1100.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. J. Gibbons and P. A. Araoz
The Year in Cardiac Imaging
J. Am. Coll. Cardiol., August 2, 2005; 46(3): 542 - 551.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2004 by the Radiological Society of North America.