Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print November 10, 2004, 10.1148/radiol.2341040589
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Appendix
Right arrow All Versions of this Article:
2341040589v1
234/1/274    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rubin, G. D.
Right arrow Articles by Napel, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rubin, G. D.
Right arrow Articles by Napel, S.
(Radiology 2005;234:274-283.)
© RSNA, 2004


Thoracic Imaging

Pulmonary Nodules on Multi–Detector Row CT Scans: Performance Comparison of Radiologists and Computer-aided Detection1

Geoffrey D. Rubin, MD, John K. Lyo, MD2, David S. Paik, PhD, Anthony J. Sherbondy, MS, Lawrence C. Chow, MD, Ann N. Leung, MD, Robert Mindelzun, MD, Pamela K. Schraedley-Desmond, PhD, Steven E. Zinck, MD, David P. Naidich, MD and Sandy Napel, PhD

1 From the Departments of Radiology (G.D.R., J.K.L., D.S.P., L.C.C., A.N.L., R.M., P.K.S.D., S.E.Z., S.N.) and Electrical Engineering (A.J.S.), Stanford University School of Medicine, 300 Pasteur Dr, S-072, Stanford, CA 94305-5105; and Department of Radiology, New York University School of Medicine, New York, NY (D.P.N.). Received March 31, 2004; revision requested June 8; revision received July 26; accepted August 19. Address correspondence to G.D.R. (e-mail: grubin@stanford.edu).

PURPOSE: To compare the performance of radiologists and of a computer-aided detection (CAD) algorithm for pulmonary nodule detection on thin-section thoracic computed tomographic (CT) scans.

MATERIALS AND METHODS: The study was approved by the institutional review board. The requirement of informed consent was waived. Twenty outpatients (age range, 15–91 years; mean, 64 years) were examined with chest CT (multi–detector row scanner, four detector rows, 1.25-mm section thickness, and 0.6-mm interval) for pulmonary nodules. Three radiologists independently analyzed CT scans, recorded the locus of each nodule candidate, and assigned each a confidence score. A CAD algorithm with parameters chosen by using cross validation was applied to the 20 scans. The reference standard was established by two experienced thoracic radiologists in consensus, with blind review of all nodule candidates and free search for additional nodules at a dedicated workstation for three-dimensional image analysis. True-positive (TP) and false-positive (FP) results and confidence levels were used to generate free-response receiver operating characteristic (ROC) plots. Double-reading performance was determined on the basis of TP detections by either reader.

RESULTS: The 20 scans showed 195 noncalcified nodules with a diameter of 3 mm or more (reference reading). Area under the alternative free-response ROC curve was 0.54, 0.48, 0.55, and 0.36 for CAD and readers 1–3, respectively. Differences between reader 3 and CAD and between readers 2 and 3 were significant (P < .05); those between CAD and readers 1 and 2 were not significant. Mean sensitivity for individual readings was 50% (range, 41%–60%); double reading resulted in increase to 63% (range, 56%–67%). With CAD used at a threshold allowing only three FP detections per CT scan, mean sensitivity was increased to 76% (range, 73%–78%). CAD complemented individual readers by detecting additional nodules more effectively than did a second reader; CAD-reader weighted {kappa} values were significantly lower than reader-reader weighted {kappa} values (Wilcoxon rank sum test, P < .05).

CONCLUSION: With CAD used at a level allowing only three FP detections per CT scan, sensitivity was substantially higher than with conventional double reading.

Supplemental material: radiology.rsnajnls.org/cgi/content/full/2341040589/DC1

© RSNA, 2004




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
F. Girvin and J. P. Ko
Pulmonary Nodules: Detection, Assessment, and CAD
Am. J. Roentgenol., October 1, 2008; 191(4): 1057 - 1069.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
M. C. Kang, C. H. Kang, H. J. Lee, J. M. Goo, Y. T. Kim, and J. H. Kim
Accuracy of 16-channel multi-detector row chest computed tomography with thin sections in the detection of metastatic pulmonary nodules
Eur. J. Cardiothorac. Surg., March 1, 2008; 33(3): 473 - 479.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. Beigelman-Aubry, P. Raffy, W. Yang, R. A. Castellino, and P. A. Grenier
Computer-Aided Detection of Solid Lung Nodules on Follow-Up MDCT Screening: Evaluation of Detection, Tracking, and Reading Time
Am. J. Roentgenol., October 1, 2007; 189(4): 948 - 955.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. E. Baker, L. Bogoni, N. A. Obuchowski, C. Dass, R. M. Kendzierski, E. M. Remer, D. M. Einstein, P. Cathier, A. Jerebko, S. Lakare, et al.
Computer-aided Detection of Colorectal Polyps: Can It Improve Sensitivity of Less-Experienced Readers? Preliminary Findings
Radiology, October 1, 2007; 245(1): 140 - 149.
[Abstract] [Full Text] [PDF]


Home page
Jpn J Clin OncolHome page
A. Suzuki, Y. Nakamoto, T. Terauchi, M. Kawamoto, Y. Okumura, Y. Suzuki, T. Sato, N. Takahashi, J. Lee, M. Senda, et al.
Inter-observer Variations in FDG-PET Interpretation for Cancer Screening
Jpn. J. Clin. Oncol., August 18, 2007; (2007) hym064v1.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. Peloschek, J. Sailer, M. Weber, C. J. Herold, M. Prokop, and C. Schaefer-Prokop
Pulmonary Nodules: Sensitivity of Maximum Intensity Projection versus That of Volume Rendering of 3D Multidetector CT Data
Radiology, May 1, 2007; 243(2): 561 - 569.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Das, G. Muhlenbruch, A. H. Mahnken, T. G. Flohr, L. Gundel, S. Stanzel, T. Kraus, R. W. Gunther, and J. E. Wildberger
Small Pulmonary Nodules: Effect of Two Computer-aided Detection Systems on Radiologist Performance.
Radiology, November 1, 2006; 241(2): 564 - 571.
[Abstract] [Full Text] [PDF]


Home page
Proc Am Thorac SocHome page
T. K. Trow
Clinical Year in Review I: Diagnostic Imaging, Asthma, Lung Transplantation, and Interventional Pulmonology
Proceedings of the ATS, September 1, 2006; 3(7): 553 - 556.
[Full Text] [PDF]


Home page
JCOHome page
C. C. Jaffe
Measures of Response: RECIST, WHO, and New Alternatives
J. Clin. Oncol., July 10, 2006; 24(20): 3245 - 3251.
[Abstract] [Full Text] [PDF]


Home page
The OncologistHome page
M. B. Lobrano
Partnerships in Oncology and Radiology: The Role of Radiology in the Detection, Staging, and Follow-up of Lung Cancer
Oncologist, July 1, 2006; 11(7): 774 - 779.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2005 by the Radiological Society of North America.