Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published online before print December 15, 2004, 10.1148/radiol.2342031323

(Radiology 2005;234:509.)

A more recent version of this article appeared on February 1, 2005
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow All Versions of this Article:
2342031323v1
234/2/509    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kuhl, C. K.
Right arrow Articles by Schild, H. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kuhl, C. K.
Right arrow Articles by Schild, H. H.
© RSNA, 2004

Neuroradiology

Acute and Subacute Ischemic Stroke at High-Field-Strength (3.0-T) Diffusion-weighted MR Imaging: Intraindividual Comparative Study1

Christiane K. Kuhl, MD, Jochen Textor, MD, Jürgen Gieseke, PhD, Marcus von Falkenhausen, MD, Sunhild Gernert, MD, Horst Urbach, MD and Hans H. Schild, MD

1 From the Department of Radiology, University of Bonn, Sigmund-Freud-Str 25, D-53105 Bonn, Germany. Received August 19, 2003; revision requested October 31; final revision received February 26, 2004; accepted April 6. Address correspondence to C.K.K. (e-mail: kuhl@uni-bonn.de).

PURPOSE: To compare signal-to-noise ratios (SNRs), contrast-to-noise ratios (CNRs), image quality, and confidence in diagnosis between 1.5- and 3.0-T diffusion-weighted (DW) magnetic resonance (MR) imaging of ischemic stroke lesions.

MATERIALS AND METHODS: The study design was approved by the institutional review board, and all patients gave informed consent. In a prospective intraindividual study, 25 patients who had clinical symptoms consistent with ischemic stroke underwent DW MR imaging at both 1.5 T and 3.0 T. The 3.0- or 1.5-T examination was performed immediately one after the other, in random order. Two readers in consensus recorded the presence and number of ischemic lesions and rated image quality and lesion conspicuity. The image SNR and the CNR of the ischemic lesions were quantified. Paired Student t and Wilcoxon matched-pairs signed rank tests were used to test for statistical significance.

RESULTS: Image quality at 3.0-T DW MR imaging was consistently lower than that at 1.5-T DW MR imaging owing to greater image distortions (P < .05). Yet, overall SNR and lesion CNR at 3.0 T increased significantly; mean increases were 48.8% (P < .001) and 96.3% (P < .01), respectively. The higher overall SNR and lesion CNR translated into a significantly higher sensitivity in the detection of ischemic lesions at 3.0 T than at 1.5 T. Of the total of 48 lesions that were identified in 19 of the 25 patients, 47 (98%) were diagnosed at 3.0 T and 36 (75%) were diagnosed at 1.5 T. In addition, the conspicuity of the lesions that were visible with both systems was significantly higher at 3.0 T (P < .001).

CONCLUSION: Although 3.0-T DW MR imaging generates greater image distortions, it yields increased SNR and CNR compared with DW MR imaging at 1.5 T. The increased CNR at 3.0 T translates into a significantly improved diagnostic confidence in the detection of focal apparent diffusion coefficient changes in the setting of subacute and acute ischemic stroke.

© RSNA, 2004




This article has been cited by other articles:


Home page
RadioGraphicsHome page
K. J. Chang, I. R. Kamel, K. J. Macura, and D. A. Bluemke
3.0-T MR Imaging of the Abdomen: Comparison with 1.5 T
RadioGraphics, November 1, 2008; 28(7): 1983 - 1998.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. K. Kuhl, F. Traber, and H. H. Schild
Whole-Body High-Field-Strength (3.0-T) MR Imaging in Clinical Practice * Part I. Technical Considerations and Clinical Applications
Radiology, March 1, 2008; 246(3): 675 - 696.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A. Bertrand, C. Oppenheim, C. Lamy, S. Rodrigo, O. Naggara, J.L. Mas, and J.F. Meder
Comparison of Optimized and Standard Diffusion-Weighted Imaging at 1.5T for the Detection of Acute Lesions in Patients with Transient Ischemic Attack
AJNR Am. J. Neuroradiol., February 1, 2008; 29(2): 363 - 365.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. M. von Falkenhausen, G. Lutterbey, N. Morakkabati-Spitz, O. Walter, J. Gieseke, R. Blomer, W. A. Willinek, H. H. Schild, and C. K. Kuhl
High-Field-Strength MR Imaging of the Liver at 3.0 T: Intraindividual Comparative Study with MR Imaging at 1.5 T
Radiology, October 1, 2006; 241(1): 156 - 166.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. K. Kuhl, P. Jost, N. Morakkabati, O. Zivanovic, H. H. Schild, and J. Gieseke
Contrast-enhanced MR Imaging of the Breast at 3.0 and 1.5 T in the Same Patients: Initial Experience
Radiology, June 1, 2006; 239(3): 666 - 676.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2004 by the Radiological Society of North America.