Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published online before print December 22, 2004, 10.1148/radiol.2342040023

(Radiology 2005;234:399.)

A more recent version of this article appeared on February 1, 2005
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow All Versions of this Article:
2342040023v1
234/2/399    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Prokop, M.
Right arrow Articles by Spinazzi, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Prokop, M.
Right arrow Articles by Spinazzi, A.
© RSNA, 2004

Contrast Media

Contrast-enhanced MR Angiography of the Renal Arteries: Blinded Multicenter Crossover Comparison of Gadobenate Dimeglumine and Gadopentetate Dimeglumine1

Mathias Prokop, MD, Günther Schneider, MD, Angelo Vanzulli, MD, Mathias Goyen, MD, Stefan G. Ruehm, MD, Philippe Douek, MD, Massimo Daprà, PhD, Gianpaolo Pirovano, MD, Miles A. Kirchin, PhD and Alberto Spinazzi, MD

1 From the Department of Radiology, University Medical Center Utrecht, Heidelberglaan 100, Utrecht 3508 GA, the Netherlands (M.P.); Department of Diagnostic Radiology, University Hospital, Homburg, Germany (G.S.); Department of Radiology, Ospedale Niguarda Ca’ Granda, Milan, Italy (A.V.); Department of Diagnostic and Interventional Radiology, University Hospital, Essen, Germany (M.G., S.G.R.); Department of Diagnostic and Therapeutic Imaging, Hôpital Cardio-Vasculaire, Lyon, France (P.D.); Worldwide Medical Affairs, Bracco Imaging, Milan, Italy (M.D., M.A.K., A.S.); and Worldwide Medical Affairs, Bracco Diagnostics, Princeton, NJ (G.P., A.S.). Received January 6, 2004; revision requested March 4; revision received April 16; accepted May 24. Address correspondence to M.P. (e-mail: m.prokop@azu.nl).

PURPOSE: To prospectively and intraindividually compare 0.1 mmol/kg gadobenate dimeglumine with 0.2 mmol/kg gadopentetate dimeglumine for contrast material–enhanced magnetic resonance (MR) angiography of the renal arteries.

MATERIALS AND METHODS: Institutional review board approval was granted by each of three participating centers. The study accorded with international standards for good clinical practice and Declaration of Helsinki and subsequent amendments. Patients gave written informed consent before enrollment. Patients (n = 34) underwent two MR angiographic examinations more than 48 hours but less than 12 days apart. Gadobenate dimeglumine followed by gadopentetate dimeglumine was administered in 18 patients; the order of administration was reversed in 16 patients. A 1.5-T MR imager was used with a phase-encoded three-dimensional spoiled breath-hold pulse sequence. Two blinded independent readers qualitatively assessed randomized subtracted maximum intensity projection images. A three-point scale for diagnostic quality (0, poor; 1a or 1p, moderate; and 2a or 2p, adequate [a and p refer, respectively, to absence and presence of vascular lesions]) was used to score each of nine segments of the abdominal aorta and both renal arteries (possible overall score, 18). Quantitative assessment (vessel signal-to-noise ratio [SNR], vessel-muscle contrast-to-noise ratio [CNR]) of source images was performed for regions of interest in supra-, juxta-, and infrarenal aorta segments and psoas muscle. Data were tested with analysis of variance for two-period crossover design. Interreader agreement was evaluated with Cohen {kappa} statistics.

RESULTS: No difference in mean image quality between the two contrast agents was observed; scores for gadobenate dimeglumine and gadopentetate dimeglumine were 15.15 and 15.23 for reader 1 and 16.77 and 17.01 for reader 2. The order of contrast material administration likewise produced no quality differences: readers 1 and 2 reported scores of 14.4 ± 4.2 (standard deviation) and 16.7 ± 2.3, respectively, when gadobenate dimeglumine was given first, and 15.2 ± 1.8 and 16.6 ± 1.6, respectively, when gadopentetate dimeglumine was given first. Results of quantitative evaluation showed increasing SNR and CNR with gadobenate dimeglumine in segments at progressively lower levels of the aorta, but increases in SNR and CNR at the infrarenal aorta (48.3 vs 40.6 and 44.2 vs 36.4, respectively) were not significant (P = .05 for both).

CONCLUSION: Gadobenate dimeglumine at a dose of 0.1 mmol/kg is comparable to gadopentetate dimeglumine at 0.2 mmol/kg for contrast-enhanced renal MR angiography.

© RSNA, 2004




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
F. Pediconi, C. Catalano, S. Padula, A. Roselli, V. Dominelli, S. Cagioli, M. A. Kirchin, G. Pirovano, and R. Passariello
Contrast-Enhanced MR Mammography: Improved Lesion Detection and Differentiation with Gadobenate Dimeglumine
Am. J. Roentgenol., November 1, 2008; 191(5): 1339 - 1346.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
N. Anzalone, F. Scomazzoni, M. Cirillo, C. Righi, F. Simionato, M. Cadioli, A. Iadanza, M.A. Kirchin, and G. Scotti
Follow-Up of Coiled Cerebral Aneurysms at 3T: Comparison of 3D Time-of-Flight MR Angiography and Contrast-Enhanced MR Angiography
AJNR Am. J. Neuroradiol., September 1, 2008; 29(8): 1530 - 1536.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. Schneider, M. Uder, M. Koehler, M. A. Kirchin, A. Massmann, A. Buecker, and U. Geisthoff
MR Angiography for Detection of Pulmonary Arteriovenous Malformations in Patients with Hereditary Hemorrhagic Telangiectasia
Am. J. Roentgenol., April 1, 2008; 190(4): 892 - 901.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. Soulez, M. Pasowicz, G. Benea, L. Grazioli, J. P. Niedmann, M. Konopka, P. C. Douek, G. Morana, F. K. W. Schaefer, A. Vanzulli, et al.
Renal Artery Stenosis Evaluation: Diagnostic Performance of Gadobenate Dimeglumine-enhanced MR Angiography--Comparison with DSA
Radiology, April 1, 2008; 247(1): 273 - 285.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Thurnher, S. Miller, G. Schneider, C. Ballarati, G. Bongartz, C. U. Herborn, S. Schoenberg, M. A. Cova, G. Morana, K. Niazi, et al.
Diagnostic Performance of Gadobenate Dimeglumine Enhanced MR Angiography of the Iliofemoral and Calf Arteries: A Large-Scale Multicenter Trial
Am. J. Roentgenol., November 1, 2007; 189(5): 1223 - 1237.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. Pediconi, C. Catalano, A. Roselli, S. Padula, F. Altomari, E. Moriconi, A. M. Pronio, M. A. Kirchin, and R. Passariello
Contrast-enhanced MR Mammography for Evaluation of the Contralateral Breast in Patients with Diagnosed Unilateral Breast Cancer or High-Risk Lesions
Radiology, June 1, 2007; 243(3): 670 - 680.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. Sardanelli, M. Quarenghi, T. Schlosser, and J. Barkhausen
Delayed Enhancement of Subendocardial Infarcted Myocardium with Gadobenate Dimeglumine: A Paradoxical Effect--Is a Double Dose Too Much?
Radiology, September 1, 2006; 240(3): 914 - 916.
[Full Text] [PDF]


Home page
RadiologyHome page
K. R. Maravilla, J. A. Maldjian, I. M. Schmalfuss, M. J. Kuhn, B. C. Bowen, F. J. Wippold II, V. M. Runge, M. V. Knopp, S. Kremer, L. J. Wolansky, et al.
Contrast Enhancement of Central Nervous System Lesions: Multicenter Intraindividual Crossover Comparative Study of Two MR Contrast Agents
Radiology, August 1, 2006; 240(2): 389 - 400.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. Pediconi, C. Catalano, R. Occhiato, F. Venditti, F. Fraioli, A. Napoli, M. A. Kirchin, and R. Passariello
Breast Lesion Detection and Characterization at Contrast-enhanced MR Mammography: Gadobenate Dimeglumine versus Gadopentetate Dimeglumine
Radiology, October 1, 2005; 237(1): 45 - 56.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2004 by the Radiological Society of North America.