Vascular and Interventional Radiology |
1 From the Institute of Clinical Radiology, Ludwig-Maximilians-University of Munich, Marchioninistrasse 15, 81377 Munich, Germany (S.O.S., J.R., C.H.W., H.J.M., T.W., O.D., M.F.R.); and Central Biostatistics Unit, German Cancer Research Center, Heidelberg, Germany (C.I.). Received October 20, 2003; revision requested January 12, 2004; final revision received June 20; accepted July 26. Address correspondence to S.O.S. (e-mail: stefan.schoenberg@med.uni-muenchen.de).
PURPOSE: To retrospectively compare three-dimensional gadolinium-enhanced magnetic resonance (MR) angiography, performed with an integrated parallel acquisition technique for high isotropic spatial resolution, with selective digital subtraction angiography (DSA) and intravascular ultrasonography (US) for accuracy of diameter and area measurements in renal artery stenosis.
MATERIALS AND METHODS: The study was approved by the institutional review board, and consent was obtained from all patients. Forty-five patients (17 women, 28 men; mean age, 62.2 years) were evaluated for suspected renal artery stenosis. Three-dimensional gadolinium-enhanced MR angiograms were acquired with isotropic spatial resolution of 0.8 x 0.8 x 0.9 mm in 23-second breath-hold with an integrated parallel acquisition technique. In-plane diameter of stenosis was measured along vessel axis, and perpendicular diameter and area of stenosis were assessed in cross sections orthogonal to vessel axis, on multiplanar reformations. Interobserver agreement between two radiologists in measurements of in-plane and perpendicular diameters of stenosis and perpendicular area of stenosis was assessed with mean percentage of difference. In a subset of patients, degree of stenosis at MR angiography was compared with that at DSA (n = 20) and intravascular US (n = 11) by using Bland-Altman plots and correlation analyses.
RESULTS: Mean percentage of difference in stenosis measurement was reduced from 39.3% ± 78.4 (standard deviation) with use of in-plane views to 12.6% ± 9.5 with use of cross-sectional views (P < .05). Interobserver agreement for stenosis grading based on perpendicular area of stenosis was significantly better than that for stenosis grading based on in-plane diameter of stenosis (mean percentage of difference, 15.2% ± 24.2 vs 54.9% ± 186.9; P < .001). Measurements of perpendicular area of stenosis on MR angiograms correlated well with those on intravascular US images (r2 = 0.90).
CONCLUSION: Evaluation of cross-sectional images reconstructed from high-spatial-resolution three-dimensional gadolinium-enhanced MR renal angiographic data increases the accuracy of the technique and decreases interobserver variability.
© RSNA, 2005
This article has been cited by other articles:
![]() |
M. Fenchel, J. Doering, A. Seeger, U. Kramer, K. Rittig, B. Klumpp, C. D. Claussen, and S. Miller Ultrafast Whole-Body MR Angiography with Two-dimensional Parallel Imaging at 3.0 T: Feasibility Study Radiology, November 10, 2008; (2008) 2501080494. [Abstract] [Full Text] |
||||
![]() |
D. R. Hadizadeh, J. Gieseke, S. H. Lohmaier, K. Wilhelm, J. Boschewitz, F. Verrel, H. H. Schild, and W. A. Willinek Peripheral MR Angiography with Blood Pool Contrast Agent: Prospective Intraindividual Comparative Study of High-Spatial-Resolution Steady-State MR Angiography versus Standard-Resolution First-Pass MR Angiography and DSA Radiology, November 1, 2008; 249(2): 701 - 711. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Kramer, J. Wiskirchen, M. C. Fenchel, A. Seeger, G. Laub, G. Tepe, J. P. Finn, C. D. Claussen, and S. Miller Isotropic High-Spatial-Resolution Contrast-enhanced 3.0-T MR Angiography in Patients Suspected of Having Renal Artery Stenosis Radiology, April 1, 2008; 247(1): 228 - 240. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. U. Herborn, V. M. Runge, D. M. Watkins, J. M. Gendron, and L. G. Naul MR Angiography of the Renal Arteries: Intraindividual Comparison of Double-Dose Contrast Enhancement at 1.5 T with Standard Dose at 3 T Am. J. Roentgenol., January 1, 2008; 190(1): 173 - 177. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. G. Lohan, F. Barkhordarian, R. Saleh, M. Krishnam, N. Salamon, S. G. Ruehm, and J. P. Finn MR Angiography at 3 T for Assessment of the External Carotid Artery System Am. J. Roentgenol., November 1, 2007; 189(5): 1088 - 1094. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Sutter, D. Nanz, A. M. Lutz, T. Pfammatter, B. Seifert, A. Struwe, C. Heilmaier, D. Weishaupt, B. Marincek, and J. K. Willmann Assessment of Aortoiliac and Renal Arteries: MR Angiography with Parallel Acquisition versus Conventional MR Angiography and Digital Subtraction Angiography Radiology, October 1, 2007; 245(1): 276 - 284. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. F. Glockner Incidental Findings on Renal MR Angiography Am. J. Roentgenol., September 1, 2007; 189(3): 693 - 700. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. J. Michaely, H. Kramer, O. Dietrich, K. Nael, K.-P. Lodemann, M. F. Reiser, and S. O. Schoenberg Intraindividual Comparison of High-Spatial-Resolution Abdominal MR Angiography at 1.5 T and 3.0 T: Initial Experience Radiology, September 1, 2007; 244(3): 907 - 913. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. H. Maki, G. J. Wilson, W. B. Eubank, D. J. Glickerman, J. A. Millan, and R. M. Hoogeveen Navigator-Gated MR Angiography of the Renal Arteries: A Potential Screening Tool for Renal Artery Stenosis Am. J. Roentgenol., June 1, 2007; 188(6): W540 - W546. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Nikolaou, H. Kramer, C. Grosse, D. Clevert, O. Dietrich, M. Hartmann, P. Chamberlin, S. Assmann, M. F. Reiser, and S. O. Schoenberg High-Spatial-Resolution Multistation MR Angiography with Parallel Imaging and Blood Pool Contrast Agent: Initial Experience Radiology, December 1, 2006; 241(3): 861 - 872. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Kramer, S. O. Schoenberg, K. Nikolaou, A. Huber, A. Struwe, E. Winnik, B. J. Wintersperger, O. Dietrich, B. Kiefer, and M. F. Reiser Cardiovascular Screening with Parallel Imaging Techniques and a Whole-Body MR Imager Radiology, July 1, 2005; 236(1): 300 - 310. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. C. Josephs Accuracy of Computed Tomographic Angiography and Magnetic Resonance Angiography for Diagnosing Renal Artery Stenosis Perspectives in Vascular Surgery and Endovascular Therapy, June 1, 2005; 17(2): 180-1 - 182. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |