Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published online before print March 15, 2005, 10.1148/radiol.2352040331

(Radiology 2005;235:523.)

A more recent version of this article appeared on May 1, 2005
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow All Versions of this Article:
2352040331v1
235/2/523    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kalra, M. K.
Right arrow Articles by Saini, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kalra, M. K.
Right arrow Articles by Saini, S.
© RSNA, 2005

Genitourinary Imaging

Detection of Urinary Tract Stones at Low-Radiation-Dose CT with Z-Axis Automatic Tube Current Modulation: Phantom and Clinical Studies1

Mannudeep K. Kalra, MD, DNB, Michael M. Maher, MD, FFR (RCSI), FRCR, Roy V. D’Souza, MD, Stefania Rizzo, MD, Elkan F. Halpern, PhD, Michael A. Blake, FFR (RCSI), FRCR, MRCPI and Sanjay Saini, MD

1 From the Division of Abdominal Imaging and Intervention, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, White 270-E, 55 Fruit St, Boston, MA 02114. Received February 19, 2004; revision requested April 29; revision received May 21; accepted July 20. Address correspondence to M.K.K. (e-mail: mannudeep_k_kalra@yahoo.com).

PURPOSE: To evaluate depiction of urinary tract calculi at computed tomography (CT) with a z-axis modulation technique at various noise indexes to reduce radiation dose and preserve image quality.

MATERIALS AND METHODS: Sixteen radiopaque kidney stones (2.5–19.2 mm in diameter) were embedded in the collecting systems of two bovine kidneys immersed in a water bath. A kidney phantom was made by placing the kidneys in an elliptical Plexiglas phantom (32 x 20 x 20 cm) filled with physiologic saline. The phantom was scanned at 16–detector row CT with a fixed tube current (300 mA) and z-axis modulation at noise indexes of 14, 20, 25, 35, and 50; remaining imaging parameters were held constant. Two abdominal radiologists reviewed images from most to least noisy. Images were evaluated for presence of stones and size, site, and attenuation value of each stone. Readers also graded conspicuity and margins of each stone on a five-point scale. In addition, follow-up studies of 22 patients (mean age, 46 years; range, 26–57 years; male-female ratio, 14:8) with kidney and ureteral stones who underwent CT with z-axis modulation (noise index, 14 and 20) were evaluated in the same manner. Statistical analysis was performed with the Student t test, Wilcoxon signed rank test, and {kappa} test of interobserver agreement. Institutional review board approval was obtained, and informed consent was not needed.

RESULTS: In the phantom study, all 16 stones were identified on images obtained with a fixed tube current and z-axis modulation at noise indexes of 14, 20, and 25 (with a reduction in radiation dose of up to 77% compared with that of fixed tube current scanning). Three stones (<5 mm) were not visualized with z-axis modulation at noise indexes of 35 and 50. No significant difference was shown for conspicuity of kidney stones in 22 patients who underwent CT with z-axis modulation (with a 43%–66% reduction in radiation dose) when compared with results of previous fixed tube current studies (P > .05).

CONCLUSION: Kidney stones (≤2.5 mm) can be adequately depicted with the z-axis modulation technique, with a 56%–77% reduction in radiation dose. In patients with urinary tract stones, the technique results in a 43%–66% reduction in radiation dose at noise indexes of 14 and 20 without compromising stone depiction.

© RSNA, 2005




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
T. Niemann, T. Kollmann, and G. Bongartz
Diagnostic Performance of Low-Dose CT for the Detection of Urolithiasis: A Meta-Analysis
Am. J. Roentgenol., August 1, 2008; 191(2): 396 - 401.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. Herzog, D. M. Mulvihill, S. A. Nguyen, G. Savino, B. Schmidt, P. Costello, T. J. Vogl, and U. J. Schoepf
Pediatric Cardiovascular CT Angiography: Radiation Dose Reduction Using Automatic Anatomic Tube Current Modulation
Am. J. Roentgenol., May 1, 2008; 190(5): 1232 - 1240.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M.T. Russell, J.R. Fink, F. Rebeles, K. Kanal, M. Ramos, and Y. Anzai
Balancing Radiation Dose and Image Quality: Clinical Applications of Neck Volume CT
AJNR Am. J. Neuroradiol., April 1, 2008; 29(4): 727 - 731.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. T. Hsu, Z. J. Wang, A. S. L. Yu, R. G. Gould, Y. Fu, B. N. Joe, A. Qayyum, R. S. Breiman, F. V. Coakley, and B. M. Yeh
Physiology of Renal Medullary Tip Hyperattenuation at Unenhanced CT: Urinary Specific Gravity and the NaCl Concentration Gradient
Radiology, April 1, 2008; 247(1): 147 - 153.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A.B. Smith, W.P. Dillon, R. Gould, and M. Wintermark
Radiation Dose-Reduction Strategies for Neuroradiology CT Protocols
AJNR Am. J. Neuroradiol., October 1, 2007; 28(9): 1628 - 1632.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. C. Lucey, J. C. Varghese, A. Hochberg, M. A. Blake, and J. A. Soto
CT-Guided Intervention with Low Radiation Dose: Feasibility and Experience
Am. J. Roentgenol., May 1, 2007; 188(5): 1187 - 1194.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. H. Mulkens, S. Daineffe, R. De Wijngaert, P. Bellinck, A. Leonard, G. Smet, and J.-L. Termote
Urinary Stone Disease: Comparison of Standard-Dose and Low-Dose with 4D MDCT Tube Current Modulation
Am. J. Roentgenol., February 1, 2007; 188(2): 553 - 562.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
S. Namasivayam, M.K. Kalra, K.M. Pottala, S.M. Waldrop, and P.A. Hudgins
Optimization of Z-Axis Automatic Exposure Control for Multidetector Row CT Evaluation of Neck and Comparison with Fixed Tube Current Technique for Image Quality and Radiation Dose
AJNR Am. J. Neuroradiol., November 1, 2006; 27(10): 2221 - 2225.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2005 by the Radiological Society of North America.