Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published online before print March 15, 2005, 10.1148/radiol.2352040899

(Radiology 2005;235:385.)

A more recent version of this article appeared on May 1, 2005
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow All Versions of this Article:
2352040899v1
235/2/385    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Baker, J. A.
Right arrow Articles by Lo, J. Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baker, J. A.
Right arrow Articles by Lo, J. Y.
© RSNA, 2005

Breast Imaging

Accuracy of Segmentation of a Commercial Computer-aided Detection System for Mammography1

Jay A. Baker, MD, Eric L. Rosen, MD, Michele M. Crockett, MD and Joseph Y. Lo, PhD

1 From the Department of Radiology, Duke University Medical Center, Box 3800, Erwin Rd, Durham, NC 27710. Received May 19, 2004; revision requested June 30; revision received August 26; accepted October 1. Address correspondence to J.A.B. (e-mail: jay.baker@duke.edu).

PURPOSE: To assess the accuracy of segmentation in a commercially available computer-aided detection (CAD) system.

MATERIALS AND METHODS: Approval for this study was obtained from the authors’ institutional review board. Informed consent was not required by the board for this review, as data were stripped of patient identifiers. Two thousand twenty mammograms from 507 women were analyzed with the hardware and software of a commercial CAD system. The accuracy of the segmentation process was determined semiquantitatively and categorized as near perfect if the skin line of the breast was accurately detected, acceptable if only subcutaneous fat was excluded, or unacceptable if any breast parenchyma was excluded from consideration. The accuracy of segmentation was compared for different breast densities and film sizes by using logistic regression (P < .05).

RESULTS: Overall, segmentation was near perfect or acceptable in almost 96.8% of images. However, segmentation defects were significantly more common in mammograms with heterogeneously dense breast tissue (8% unacceptable) than in those with fatty replaced (0% unacceptable), scattered (1.2% unacceptable), or extremely dense (1.8% unacceptable) breast parenchyma (P < .05). For images with unacceptable segmentation, the average percentage of breast parenchyma excluded was almost 25% (range, 5%–100%), with no significant differences among breast densities.

CONCLUSION: For one commercial CAD system, segmentation was usually near perfect or acceptable but was unacceptable more than five times more frequently for mammograms of breasts with heterogeneously dense parenchyma than for those with all other breast densities. On average, one-quarter of the breast parenchyma was excluded from CAD analysis for images with unacceptable segmentation.