Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published online before print April 21, 2005, 10.1148/radiol.2353040516

(Radiology 2005;235:940.)

A more recent version of this article appeared on June 1, 2005
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow All Versions of this Article:
2353040516v1
235/3/940    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Samei, E.
Right arrow Articles by Ravin, C. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Samei, E.
Right arrow Articles by Ravin, C. E.
© RSNA, 2005

Medical Physics

Comparative Scatter and Dose Performance of Slot-Scan and Full-Field Digital Chest Radiography Systems1

Ehsan Samei, PhD, Joseph Y. Lo, PhD, Terry T. Yoshizumi, PhD, Jonathan L. Jesneck, BS, James T. Dobbins III, PhD, Carey E. Floyd, Jr, PhD, H. Page McAdams, MD and Carl E. Ravin, MD

1 From the Duke Advanced Imaging Laboratories, Department of Radiology (E.S., J.Y.L., T.T.Y., J.L.J., J.T.D., C.E.F., H.P.M., C.E.R.), Department of Biomedical Engineering (E.S., J.Y.L., J.L.J., J.T.D., C.E.F.), Department of Physics (E.S.), and Radiation Safety Division (T.T.Y.), Duke University Medical Center, DUMC 3302, Durham, NC 27710. Received March 18, 2004; revision requested May 25; revision received July 22; accepted August 19. Address correspondence to E.S. (e-mail: samei@duke.edu).

PURPOSE: To evaluate the scatter, dose, and effective detective quantum efficiency (DQE) performance of a slot-scan digital chest radiography system compared with that of a full-field digital radiography system.

MATERIALS AND METHODS: Scatter fraction of a slot-scan system was measured for an anthropomorphic and a geometric phantom by using a posterior beam-stop technique at 117 and 140 kVp. Measurements were repeated with a full-field digital radiography system with and without a 13:1 antiscatter grid at 120 and 140 kVp. For both systems, the effective dose was measured on posteroanterior and lateral views for standard clinical techniques by using dosimeters embedded in a female phantom. The effective DQEs of the two systems were assessed by taking into account the scatter performance and the DQE of each system. The statistical significance of all the comparative differences was ascertained by means of t test analysis.

RESULTS: The slot-scan system and the full-field system with grid yielded scatter fractions of 0.13–0.14 and 0.42–0.48 in the lungs and 0.30–0.43 and 0.69–0.78 in the mediastinum, respectively. The sum of the effective doses for posteroanterior and lateral views for the slot-scan system (0.057 mSv ± 0.003 [± standard deviation]) was 34% lower than that for the full-field system (0.086 mSv ± 0.001, P < .05) at their respective clinical peak voltages (140 and 120 kVp, respectively). The effective DQE of the slot-scan system was equivalent to that of the full-field system in the lung region but was 37% higher in the dense regions (P < .05).

CONCLUSION: The slot-scan design leads to marked scatter reduction compared with the more conventional full-field geometries with a grid. The improved scatter performance of a slot-scan geometry can effectively compensate for low DQE and lead to improved image quality.

© RSNA, 2005




This article has been cited by other articles:


Home page
RadiologyHome page
E. Samei, N. T. Ranger, A. MacKenzie, I. D. Honey, J. T. Dobbins III, and C. E. Ravin
Detector or System? Extending the Concept of Detective Quantum Efficiency to Characterize the Performance of Digital Radiographic Imaging Systems
Radiology, December 1, 2008; 249(3): 926 - 937.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. A. Mettler Jr, W. Huda, T. T. Yoshizumi, and M. Mahesh
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Radiology, July 1, 2008; 248(1): 254 - 263.
[Abstract] [Full Text] [PDF]


Home page
radtechHome page
J. MINIGH
Quality Assurance in Digital Mammography
Radiol. Technol., May 1, 2008; 79(5): 433M - 454M.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. P. McAdams, E. Samei, J. Dobbins III, G. D. Tourassi, and C. E. Ravin
Recent Advances in Chest Radiography
Radiology, December 1, 2006; 241(3): 663 - 683.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2005 by the Radiological Society of North America.