Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published online before print October 19, 2005, 10.1148/radiol.2373041643

(Radiology 2005;237:905.)

A more recent version of this article appeared on December 1, 2005
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow All Versions of this Article:
2373041643v1
237/3/905    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Funama, Y.
Right arrow Articles by Yamashita, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Funama, Y.
Right arrow Articles by Yamashita, Y.
© RSNA, 2005

Experimental Studies

Radiation Dose Reduction without Degradation of Low-Contrast Detectability at Abdominal Multisection CT with a Low–Tube Voltage Technique: Phantom Study1

Yoshinori Funama, PhD, Kazuo Awai, MD, Yoshiharu Nakayama, MD, Kiyotaka Kakei, RT, Nozomu Nagasue, BS, Masamichi Shimamura, PhD, Natsuko Sato, BS, Shamima Sultana, MD, Shoji Morishita, MD and Yasuyuki Yamashita, MD

1 From the Department of Radiological Sciences, School of Health Sciences (Y.F., M.S.), and Department of Diagnostic Radiology, Graduate School of Medical Sciences (K.A., Y.N., S.S., S.M., Y.Y.), Kumamoto University, 4.24.1 Kuhonji, Kumamoto 862-0976, Japan; Department of Radiology, Kumamoto University Hospital, Kumamoto, Japan (K.K., N.N.); and Philips Medical Systems, Minato-ku, Tokyo, Japan (N.S.). Received September 23, 2004; revision requested November 30; revision received January 23, 2005; accepted February 23. Address correspondence to Y.F.

PURPOSE: To reduce radiation dose from abdominal computed tomography (CT) without degradation of low-contrast detectability by using a technique with low tube voltage (90 kV).

MATERIALS AND METHODS: The institutional review board approved the participation of the radiologists in the observer performance test, and informed consent was obtained from all participating radiologists. A phantom for measurement of the radiation dose and a phantom containing low-contrast objects were scanned with a 16–detector row CT scanner at 120 kV and 90 kV. For determination of the radiation dose at both 90 kV and 120 kV, the tube current–time product settings were 100–560 mAs, and the doses at the center and periphery of the phantom were measured. To assess low-contrast detectability, we used a 300-mAs setting at 120 kV and 250–560-mAs settings at 90 kV. Five observers participated in the receiver operating characteristic analysis. Area under the receiver operating characteristic curve (Az) values were calculated in each observer. Az values obtained with each of the scanning techniques were recorded, and differences were examined for significance by using the Dunnet method.

RESULTS: The mean Az value was 0.951 at 120 kV and 300 mAs. Az values were 0.927–0.973 at 90 kV and 450–560 mAs, and the differences between those values and values obtained at 120 kV and 300 mAs were not significant (P = .937–.952). A value of 100% was assigned to the radiation dose delivered to the center of the phantom at 120 kV and 300 mAs. The relative dose delivered at 90 kV ranged from 65% at 450 mAs to 79% at 560 mAs.

CONCLUSION: A reduction from 120 kV to 90 kV led to as much as a 35% reduction in the radiation dose, without sacrifice of low-contrast detectability, at CT.

© RSNA, 2005




This article has been cited by other articles:


Home page
RadiologyHome page
S. T. Schindera, R. C. Nelson, S. Mukundan Jr, E. K. Paulson, T. A. Jaffe, C. M. Miller, D. M. DeLong, K. Kawaji, T. T. Yoshizumi, and E. Samei
Hypervascular Liver Tumors: Low Tube Voltage, High Tube Current Multi Detector Row CT for Enhanced Detection Phantom Study
Radiology, December 1, 2007; 246(1): 125 - 132.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
Y. Yanaga, K. Awai, Y. Nakayama, T. Nakaura, Y. Tamura, M. Hatemura, and Y. Yamashita
Pancreas: Patient Body Weight tailored Contrast Material Injection Protocol versus Fixed Dose Protocol at Dynamic CT
Radiology, November 1, 2007; 245(2): 475 - 482.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
Y. Nakayama, K. Awai, Y. Funama, D. Liu, T. Nakaura, Y. Tamura, and Y. Yamashita
Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography.
Am. J. Roentgenol., November 1, 2006; 187(5): W490 - W497.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. H. McCollough
Automatic Exposure Control in CT: Are We Done Yet?
Radiology, December 1, 2005; 237(3): 755 - 756.
[Full Text] [PDF]


Home page
RadiologyHome page
Y. Nakayama, K. Awai, Y. Funama, M. Hatemura, M. Imuta, T. Nakaura, D. Ryu, S. Morishita, S. Sultana, N. Sato, et al.
Abdominal CT with Low Tube Voltage: Preliminary Observations about Radiation Dose, Contrast Enhancement, Image Quality, and Noise
Radiology, December 1, 2005; 237(3): 945 - 951.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2005 by the Radiological Society of North America.