Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online before print December 21, 2005, 10.1148/radiol.2382042182
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
2382042182v1
238/2/719    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sun, F.
Right arrow Articles by Maynar, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sun, F.
Right arrow Articles by Maynar, M.
(Radiology 2005;238:719-724.)
© RSNA, 2005


Technical Developments

Subxiphoid Access to Normal Pericardium with Micropuncture Set: Technical Feasibility Study in Pigs1

Fei Sun, MD, Francisco M. Sánchez, DVM, PhD, Verónica Crisóstomo, DVM, PhD, Laura Luis, DVM, PhD, Jesús Usón, DVM, PhD and Manuel Maynar, MD, PhD

1 From the Center for Minimally Invasive Surgery, Campus Universitario, Avenida de la Universidad, s/n, 10071 Cáceres, Spain. Received December 23, 2004; revision requested February 23, 2005; revision received February 28; accepted March 15; final version accepted April 18. Address correspondence to F.S. (e-mail: feisun{at}ccmi.es).

This study was performed with approval from the ethics committee for animal research of the local government. The purpose of the study was to evaluate the technical feasibility of a technique for subxiphoid access to the normal pericardial space with a micropuncture set in 10 large white pigs. With fluoroscopic guidance, a fine needle was inserted through a subxiphoid approach into the anterior mediastinal space to puncture the pericardium, and a micropuncture set was placed in the pericardial space successfully in all animals without complications. Necropsy at 24 hours did not reveal hemomediastinum, hemopericardium, or laceration of the pericardium. Results of the experiments in animals indicated that the technique was feasible and safe.

© RSNA, 2005