Gastrointestinal Imaging |
1 From the Department of Radiology, Chonnam National University Hospital, Chonnam National University Medical School, 8 Hak-dong, Dong-gu, Gwangju 501-757, Republic of Korea. Received February 3, 2005; revision requested April 4; revision received April 18; accepted June 3; final version accepted June 20. Address correspondence to W.Y. (e-mail: radyoon{at}chonnam.ac.kr).
Purpose: To prospectively evaluate accuracy of arterial phase multidetector row helical computed tomography (CT) for detection and localization of acute massive gastrointestinal (GI) bleeding, with angiography as reference standard.
Materials and Methods: Institutional review board approved this study; written informed consent was obtained from each patient or patient's family after procedures, including radiation dose, were explained. Twenty-six consecutive patients (17 men, nine women; age range, 1889 years) had acute massive GI bleeding (defined as requirement of transfusion of at least 4 units of blood during 24 hours in the hospital or as hypotension with systolic blood pressure <90 mm Hg) and underwent arterial phase multidetector row CT before angiography. Scans were obtained during arterial phase to identify extravasation of contrast material with attenuation greater than 90 HU within bowel lumen; this finding was considered diagnostic for active GI bleeding. Presence of contrast medium extravasation in each anatomic location was recorded. Sensitivity, specificity, positive and negative predictive values, and accuracy of multidetector row CT for detection of acute GI bleeding were assessed. Accuracy for localization of acute GI bleeding was assessed by comparing locations of active bleeding at both multidetector row CT and angiography in each patient who had active bleeding.
Results: Arterial phase multidetector row CT depicted extravasation of contrast material in 21 of 26 patients. Overall location-based sensitivity, specificity, accuracy, and positive and negative predictive values of multidetector row CT for detection of GI bleeding were 90.9% (20 of 22), 99% (107 of 108), 97.6% (127 of 130), 95% (20 of 21), and 98% (107 of 109), respectively. Overall patient-based accuracy of multidetector row CT for detection of acute GI bleeding was 88.5% (23 of 26). The location of contrast material extravasation on multidetector row CT scans corresponded exactly to that of active bleeding on angiograms in all patients with contrast medium extravasation at both multidetector row CT and angiography.
Conclusion: Arterial phase multidetector row CT is accurate for detection and localization of bleeding sites in patients with acute massive GI bleeding.
© RSNA, 2006
This article has been cited by other articles:
![]() |
S. I. Zink, S. K. Ohki, B. Stein, D. A. Zambuto, R. J. Rosenberg, J. J. Choi, and D. S. Tubbs Noninvasive Evaluation of Active Lower Gastrointestinal Bleeding: Comparison Between Contrast-Enhanced MDCT and 99mTc-Labeled RBC Scintigraphy Am. J. Roentgenol., October 1, 2008; 191(4): 1107 - 1114. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. M. Elsayes, C. O. Menias, J. R. Dillman, J. F. Platt, J. M. Willatt, and J. P. Heiken Vascular Malformation and Hemangiomatosis Syndromes: Spectrum of Imaging Manifestations Am. J. Roentgenol., May 1, 2008; 190(5): 1291 - 1299. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Roy-Choudhury and S. Karandikar Multidetector CT of Acute Gastrointestinal Bleeding Radiology, January 1, 2008; 246(1): 336 - 336. [Full Text] [PDF] |
||||
![]() |
S. H. Roy-Choudhury, D. J. Gallacher, J. Pilmer, S. Rankin, G. Fowler, J. Steers, R. Dourado, P. Woodburn, and A. Adam Relative Threshold of Detection of Active Arterial Bleeding: In Vitro Comparison of MDCT and Digital Subtraction Angiography Am. J. Roentgenol., November 1, 2007; 189(5): W238 - W246. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. S. Lim, W. J. Hyung, M.-S. Park, M.-J. Kim, S. H. Noh, and K. W. Kim Imaging-Guided Minimally Invasive Laparoscopic Resection of Intraluminal Small-Bowel Tumor: Report of Two Cases Am. J. Roentgenol., July 1, 2007; 189(1): 56 - 60. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. J. Laing, T. Tobias, D. I. Rosenblum, W. L. Banker, L. Tseng, and S. W. Tamarkin Acute Gastrointestinal Bleeding: Emerging Role of Multidetector CT Angiography and Review of Current Imaging Techniques RadioGraphics, July 1, 2007; 27(4): 1055 - 1070. [Abstract] [Full Text] [PDF] |
||||
![]() |
S Anthony and R Uberoi The current status of imaging in acute gastrointestinal haemorrhage Imaging, December 1, 2006; 18(4): 193 - 197. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH |
| RADIOLOGY | RADIOGRAPHICS | RSNA JOURNALS ONLINE |