Radiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
 QUICK SEARCH:   [advanced]


     


Published online before print October 10, 2006, 10.1148/radiol.2413060053

(Radiology 2006;241:861.)

A more recent version of this article appeared on December 1, 2006
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Table E1
Right arrow Appendix E1
Right arrow All Versions of this Article:
2413060053v1
241/3/861    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nikolaou, K.
Right arrow Articles by Schoenberg, S. O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nikolaou, K.
Right arrow Articles by Schoenberg, S. O.
© RSNA, 2006

Technical Developments

High-Spatial-Resolution Multistation MR Angiography with Parallel Imaging and Blood Pool Contrast Agent: Initial Experience1

Konstantin Nikolaou, MD, Harald Kramer, MD, Christina Grosse, MD, Dirk Clevert, MD, Olaf Dietrich, PhD, Mike Hartmann, Paul Chamberlin, MD, Stefan Assmann, PhD, Maximilian F. Reiser, MD and Stefan O. Schoenberg, MD

1 From the Department of Clinical Radiology, Ludwig-Maximilians University of Munich, Grosshadern Campus, Marchioninistr 15, 81377 Munich, Germany (K.N., H.K., C.G., D.C., O.D., M.F.R., S.O.S.); EPIX Pharmaceuticals, Cambridge, Mass (M.H., P.C.); and Siemens Medical Solutions, Erlangen, Germany (S.A.). Received January 11, 2006; revision requested March 9; revision received April 13; accepted May 17; final version accepted June 16. Supported by EPIX Pharmaceuticals. Address correspondence to K.N. (e-mail: Konstantin.Nikolaou{at}med.uni-muenchen.de).

The purpose of this study was to prospectively evaluate the diagnostic accuracy of reader detection of 75% or greater stenosis at high-spatial-resolution multistation magnetic resonance (MR) angiography performed with matrix coils and a blood pool contrast agent. Ten healthy volunteers and 10 patients were examined. All participants provided informed consent to participate in this institutional review board–approved study. For contrast agent–enhanced multistation MR angiography, an albumin-binding gadolinium chelate, gadofosveset trisodium, was used. Imaging was performed during the first-pass and steady-state phases of the contrast agent. Vessel conspicuity on the first-pass MR angiograms obtained in both volunteers and patients was rated as excellent for 93% of vessels. At steady-state imaging, vessel conspicuity was rated as excellent or good for 89% of vessels. Gadofosveset trisodium–enhanced MR angiography yielded sensitivities of 100% and 97% and specificities of 96% and 97% for detection of significant disease in the carotid and lower extremity arteries, respectively.

Supplemental material:
radiology.rsnajnls.org/cgi/content/full/2413060053/DC1
radiology.rsnajnls.org/cgi/content/full/2413060053/DC2

© RSNA, 2006







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH
RADIOLOGY RADIOGRAPHICS RSNA JOURNALS ONLINE
Copyright © 2006 by the Radiological Society of North America.